ENGLISH ENGLISH ESPAÑOL
INSTALLATION MANUAL
GAS DOUBLE OVEN RANGE
Please read this guide thoroughly before installation.
LDG3019ST
LDG3017ST
LDG3016ST
LDG3015ST/SB/SW
LDG3011ST
P/No.: MFL62177703
www.lg.com
Summary of the content on the page No. 2
INSTALLATION INSTRUCTIONS READ ALL INSTRUCTIONS BEFORE INSTALLATION INSTALLATION SAFETY INSTRUCTIONS BEFORE YOU BEGIN Note to Installer: Leave these instructions with Read these instructions completely the appliance after installation is completed. and carefully. Note to Consumer: Keep the User’s Guide and Installation of this range must conform with local Installation Instructions for future reference. codes, or in the absence of local codes, with the National Fuel Gas Code, ANSI Z223.1/NF
Summary of the content on the page No. 3
ENGLISH INSTALLATION INSTRUCTIONS READ ALL INSTRUCTIONS BEFORE INSTALLATION INSTALLATION SAFETY INSTRUCTIONS (continued) BEFORE YOU BEGIN Remove all tape and packing materials before using the range. Dispose of all plastic bags after unpacking the range. Never allow children to play with packing materials. IMPORTANT SAFETY INSTRUCTIONS Read these instructions completely and carefully. Improper installation, adjustment, alteration, service or maintenance can cause injury or property damage. Refe
Summary of the content on the page No. 4
INSTALLATION INSTRUCTIONS READ ALL INSTRUCTIONS BEFORE INSTALLATION INSTALLATION SAFETY INSTRUCTIONS (continued) - If the range is pulled away from the wall for WARNING! cleaning, service, or any other reason, ensure that the Anti-Tip Device is properly reengaged when • ALL RANGES CAN TIP the range is pushed back against the wall. • INJUR Y TO PERSONS All ranges can tip and injury could result. To prevent COULD RESULT accidental tipping of the range, attach an approved • INSTALL ANTI-TI
Summary of the content on the page No. 5
ENGLISH INSTALLATION INSTRUCTIONS READ ALL INSTRUCTIONS BEFORE INSTALLATION INSTALLATION SAFETY INSTRUCTIONS (continued) WARNING! • If a 30” clearance between cooking surface and • The vertical distance from the plane of the cooking overhead combustible material or metal cabinets surface to the bottom of adjacent overhead cannot be maintained, protect the underside of the cabinets extending closer than 1” to the plane of cabinets above the cooktop with not less than 1/4” the range sides mus
Summary of the content on the page No. 6
INSTALLATION INSTRUCTIONS DIMENSIONS AND CLEARANCES Provide proper clearances between the range and The range may be placed with 0” clearance (flush) at adjacent combustible surfaces. These dimensions the back wall. must be met for safe use of your range. The location of the electrical outlet and pipe opening (see “GAS PIPE AND ELECTRICAL OUTLET LOCATIONS”) may be adjusted to meet specific requirements. INSTALLATION CLEARANCES Maximum depth Maximum depth Minimum to for cabinets Minimum to fo
Summary of the content on the page No. 7
ENGLISH INSTALLATION INSTRUCTIONS LOCATION Do not locate your range where it may be subject When the floor covering ends at the front of the to strong drafts. Any openings in the floor or wall range, the area that the range will be installed on behind the range should be sealed. Make sure the should be built up with plywood to the same level or openings around the base of the range that higher than the floor covering. This will allow the supply fresh air for combustion and ventilation range
Summary of the content on the page No. 8
INSTALLATION INSTRUCTIONS GAS PIPE AND ELECTRICAL OUTLET LOCATIONS 30” 1 / 9 16” 3 / 11 32” 2” Recommended area for 120V outlet on rear wall and area for 19 / 8 32” through-the wall connection of 3” pipe stub and shut-off valve. 5 / 14 16” 3 / 2 8” Recommended area for through-the floor connection of pipe stub and shut-off valve. 1. PROVIDE ADEQUATE GAS SUPPLY Your range is designed to operate at a pressure of For LP gas, the pressure supplied to the regulator 5” of water column on natural gas
Summary of the content on the page No. 9
ENGLISH INSTALLATION INSTRUCTIONS 2. CONNECT THE RANGE TO GAS Shut off the range gas supply valve before Connect a flexible metal appliance connector to C removing the old range and leave it off until the the adapter on the range. Position range to permit new hook-up has been completed. connection at the shut-off valve. Because hard piping restricts movement of the range, the use of a CSA International-certified flexible metal When all connections have been made, be sure D appliance
Summary of the content on the page No. 10
INSTALLATION INSTRUCTIONS 3. ELECTRICAL CONNECTIONS ELECTRICAL REQUIREMENTS 120 Volt, 60 Hertz, properly grounded dedicated circuit protected by a 15 or 20 Amp circuit breaker, or slow blow fuse. GROUNDING IMPORTANT: FOR PERSONAL SAFETY, THIS APPLIANCE MUST BE PROPERLY GROUNDED. The power cord of this appliance is equipped with a 3-prong (grounding) plug which mates with a standard CAUTION: 3-prong grounding wall receptacle to minimize the The customer should have the circuit checked by a p
Summary of the content on the page No. 11
ENGLISH INSTALLATION INSTRUCTIONS 5. ASSEMBLE THE SURFACE BURNERS CAUTION Hole DO NOT operate the burners without all parts in place. Electrode Place the burner caps and heads on the cooktop. Make sure that the caps and heads are placed in the correct locations. There is one small, one medium, one large and one extra large burner head and cap. Make sure the hole in the burner head is positioned Center Burner (on some models) (on some models) over the electrode. Oval (Center) Burner Medium b
Summary of the content on the page No. 12
INSTALLATION INSTRUCTIONS 7. ADJUST THE SURFACE BURNER TO THE LOW FLAME(SIMMER) SETTING. 1) Light all surface burners. 2) Turn the knob on the burner being adjusted to “LO”. 3) Remove knob. 4) Insert a small, flat bladed screwdriver into the valve Center adjustment screw Adjustment screw next to shaft as shown in Fig. 1. the valve shaft On right front valve for model LDG3019ST there is a secondary adjustment for the low flame for the Fig. 1 Fig. 2 outer burners. Insert a small, flat
Summary of the content on the page No. 13
ENGLISH INSTALLATION INSTRUCTIONS 8. CHECK OPERATION OF BAKE/BROIL BURNERS To check ignition of the Bake burner, follow the steps To check ignition of the Broil burner, follow the steps below: below: 1) Remove all packing from inside the oven cavity. 1) Press "Broil" ("Hi" will be shown in the display). 2) Press "Bake" (350 will be shown in the display). 2) Make sure the door is closed. 3) Press Start. 3) Press Start. It may take between 30 and 90 seconds for the burner It may take between 30 a
Summary of the content on the page No. 14
INSTALLATION INSTRUCTIONS 10. INSTALLING THE ANTI-TIP DEVICE INSTALL THE BRACKET USING THE WARNING BRACKET INSTALLATION SHEET • Range must be secured with an approved Anti-Tip device. • The range could be tipped by standing, sitting or leaning on an open door if the range or Anti-Tip device is not properly installed. • After installing the Anti-Tip device, verify that it is in place by carefully attempting to tilt the range forward. • This range has been designed to meet all The Anti-
Summary of the content on the page No. 15
ENGLISH INSTALLATION INSTRUCTIONS WHEN ALL HOOKUPS ARE COMPLETE Make sure all controls are left in the off position. Make sure the flow of combustion and ventilation air to the range is unblocked. CONVERTING TO LP GAS (OR CONVERTING BACK TO NATURAL GAS FROM LP) This range leaves the factory set for use with The conversion instructions and LP orifices can be natural gas. The conversion to LP gas must be found attached to the range on the back. performed by a qualified LP gas installer when Kee
Summary of the content on the page No. 16
Memo 16
Summary of the content on the page No. 17
LG Customer Information Center 1-800-243-0000 USA, Consumer User 1-888-865-3026 USA, Commercial User Register your product Online! www.lg.com Printed in Mexico