Bryant 580J*04--12 user manual

User manual for the device Bryant 580J*04--12

Device: Bryant 580J*04--12
Category: Air Conditioner
Manufacturer: Bryant
Size: 4.39 MB
Added : 11/14/2014
Number of pages: 73
Print the manual

Download

How to use this site?

Our goal is to provide you with a quick access to the content of the user manual for Bryant 580J*04--12. Using the online preview, you can quickly view the contents and go to the page where you will find the solution to your problem with Bryant 580J*04--12.

For your convenience

If looking through the Bryant 580J*04--12 user manual directly on this website is not convenient for you, there are two possible solutions:

  • Full Screen Viewing - to easily view the user manual (without downloading it to your computer), you can use full-screen viewing mode. To start viewing the user manual Bryant 580J*04--12 on full screen, use the button Fullscreen.
  • Downloading to your computer - You can also download the user manual Bryant 580J*04--12 to your computer and keep it in your files. However, if you do not want to take up too much of your disk space, you can always download it in the future from ManualsBase.
Bryant 580J*04--12 User manual - Online PDF
Advertisement
« Page 1 of 73 »
Advertisement
Print version

Many people prefer to read the documents not on the screen, but in the printed version. The option to print the manual has also been provided, and you can use it by clicking the link above - Print the manual. You do not have to print the entire manual Bryant 580J*04--12 but the selected pages only. paper.

Summaries

Below you will find previews of the content of the user manuals presented on the following pages to Bryant 580J*04--12. If you want to quickly view the content of pages found on the following pages of the manual, you can use them.

Abstracts of contents
Summary of the content on the page No. 1

580J*04--12
NOMINAL3TO10TONS
WITHPURONr(R410A)REFRIGERANT
ServiceandMaintenanceInstructions
Follow all safety codes. Wear safety glasses and work
TABLEOFCONTENTS
gloves. Use quenching cloth for unbrazing operations.
SAFETY CONSIDERATIONS .................... 1 Have fire extinguishers available for all brazing
operations.
UNIT ARRANGEMENT AND ACCESS ........... 2
SUPPLY FAN (BLOWER) SECTION .............. 4 Follow all safety codes. Wear safety glasses and work
gloves. Use quenching cloth for braz

Summary of the content on the page No. 2

FILTER ACCESS PANEL ! WARNING ELECTRICALOPERATIONHAZARD Failure to follow this warning could result in personal injuryordeath. Before performing service or maintenance operations on unit, turn off main power switch to unit. Electrical shockandrotatingequipment couldcause injury. COMPRESSOR ACCESS PANEL (04-07 only) OUTDOOR-AIR OPENING AND INDOOR COIL ACCESS PANEL ! WARNING C08449 Fig. 1 -- Typical AccessPanel Locations ELECTRICALOPERATIONHAZARD Failure to follow this warning could result in pers

Summary of the content on the page No. 3

S Wire terminal tightness washing with hot low--pressure water and soft detergent and replace all screens before restarting the unit. Observe S Refrigerant charge level the flow direction arrows on the side of each filter frame. S Evaporatorcoil cleaning EconomizerInletAirScreen S Evaporatorblowermotoramperage This air screen is retained by spring clips under the top Heating edge of the hood. (See Fig. 3.) S Heat exchangerflue passagewayscleanliness 17 1/4” S Gasburnercondition S Gasmanifoldpres

Summary of the content on the page No. 4

Re--install by placing the frame in its track, rotating the new belt, do not use a tool (screwdriveror pry--bar)to retainer back down and tighten all screws. force the belt over the pulley flanges, this will stress the belt and cause a reduction in belt life. 2. Loosen the motor mounting plate front bolts and rear SUPPLYFAN(BLOWER)SECTION bolts. 3. Push the motor and its mounting plate towards the ! WARNING blower housing as close as possible to reduce the cen- ter distance between fan shaft and

Summary of the content on the page No. 5

Before changing pulleys to increase fan wheel speed, check the fan performance at the target speed and airflow rate to determine new motor loading (bhp). Use the fan performance tables or use the Packaged Rooftop Builder software program. Confirm that the motor in this unit is capable of operating at the new operating condition. Fan shaft loading increases dramatically as wheel speed is increased. To reduce vibration, replace the motor’s adjustable pitch pulley with a fixed pitch pulley (after t

Summary of the content on the page No. 6

difficult. Surface loaded fibers must be completely 6. Use a water hose or other suitable equipment to flush removed prior to using low velocity clean water rinse. down between the 2 coil sections to remove dirt and debris. Clean the outer surfaces with a stiff brush in PeriodicCleanWater Rinse the normal manner. A periodic clean water rinse is very beneficial for coils 7. Secure inner and outer coil rows together with a that are applied in coastal or industrial environments. field--supplied fas

Summary of the content on the page No. 7

11. Thoroughly rinse all surfaces with low velocity clean ! CAUTION water using downward rinsing motion of water spray nozzle. Protect fins from damage from the spray UNIT DAMAGE HAZARD nozzle. Failure tofollowthiscautionmayresult inaccelerated EvaporatorCoil corrosion of unit parts. CleaningtheEvaporator Coil Harsh chemicals, household bleach or acid or basic 1. Turn unit power off. Install lockout tag. Remove cleaners should not be used to clean outdoor or indoor evaporator coil access panel.

Summary of the content on the page No. 8

SEAT CORE (Part No. EC39EZ067) 1/2-20 UNF RH 0.596 o 45 o 30 WASHER DEPRESSOR PER ARI 720 O-RING +.01/-.035 1/2" HEX .47 FROM FACE OF BODY 5/8” HEX 7/16-20 UNF RH This surface provides a metal to metal seal when torqued into the seat. Appropriate handling is required to not scratch or dent the surface. C08453 Fig. 11 -- CoreMax AccessPort Assembly required. Connect the pressure gauge to the service port PURONR(R410A)REFRIGERANT on the suction line. Mount the temperature sensing device o

Summary of the content on the page No. 9

COOLINGCHARGINGCHARTS C08203 C08204 Fig. 12 -- Cooling Charging Charts 9 580J

Summary of the content on the page No. 10

COOLINGCHARGINGCHARTS(cont) C08228 C08229 Fig. 12 -- CoolingChargingCharts(cont.) 10 580J

Summary of the content on the page No. 11

COOLINGCHARGINGCHARTS(cont.) C08437 C08438 Fig. 12 -- CoolingChargingCharts(cont.) 11 580J

Summary of the content on the page No. 12

COOLINGCHARGINGCHARTS(cont.) C08439 Fig. 12 -- CoolingChargingCharts(cont.) 12 580J

Summary of the content on the page No. 13

The suction and discharge pressure levels should now Compressor move to their normal start--up levels. Lubrication NOTE: When the compressor is rotating in the wrong The compressor is charged with the correct amount of oil direction, the unit makes an elevated level of noise and at the factory. does not provide cooling. FilterDrier ! CAUTION Replace whenever refrigerant system is exposed to atmosphere. Only use factory specified liquid--line filter UNIT DAMAGE HAZARD driers with working pressure

Summary of the content on the page No. 14

Table1–CoolingServiceAnalysis PROBLEM CAUSE REMEDY Power failure. Callpowercompany. Fuseblownorcircuitbreakertripped. Replacefuseorresetcircuitbreaker. Defectivethermostat,contactor,transformer, Replacecomponent. CompressorandCondenser orcontrolrelay. Fan WillNotStart. Insufficientlinevoltage. Determinecauseand correct. Incorrectorfaulty wiring. Checkwiring diagramand rewirecorrectly. Thermostatsetting toohigh. Lowerthermostatsetting belowroomtemperature. Faultywiring orlooseconnectionsincompres

Summary of the content on the page No. 15

when the unit disconnect or HACR switch is open. See CONVENIENCEOUTLETS Fig. 15. ! WARNING ELECTRICALOPERATIONHAZARD Failure to follow this warning could result in personal injuryordeath. Units with convenience outlet circuits may use multiple disconnects. Check convenience outlet for power status before opening unit for service. Locate its disconnect switch, if appropriate, and open it. Tag--out thisswitch, ifnecessary. Two types of convenience outlets are offered on 580J models: Non--powered a

Summary of the content on the page No. 16

Sensor SMOKEDETECTORS The sensor (see Fig. 17) includes a plastic housing, a Smoke detectors are available as factory--installed options printed circuit board, a clear plastic cover, a sampling on 580J models. Smoke detectors may be specified for tube inlet and an exhaust tube. The sampling tube (when Supply Air only or for Return Air without or with used) and exhaust tube are attached during installation. economizer or in combination of Supply Air and Return The sampling tube varies in length d

Summary of the content on the page No. 17

such as smoke from a fire, causes the sensor to signal an Return Air with Economizer — The sampling tube is alarm state but dust and debris accumulated over time inserted through the side plates of the economizer does not. housing, placing it across the return air opening on the unit basepan. See Fig. 20. The holes in the sampling tube For installations using two sensors, the duct smoke face downward, into the return air stream. The sampling detector does not differentiate which sensor signals a

Summary of the content on the page No. 18

tion of the flexible tubing to the sampling tube is the condition is detected. See Fig. 23, Smoke Detector same. Wiring. Highlight A: JMP 3 is factory--cut, transferring unit control to smoke detector. Highlight B: Smoke detector NC contact set will open on smoke alarm condition, de--energizing the ORN conductor. Highlight C: 24--v power signal via ORN lead is removed at Smoke Detector input on LCTB; all unit operations cease immediately. Using Remote Logic: Five conductors are provided for fiel

Summary of the content on the page No. 19

SENSORANDCONTROLLERTESTS ! CAUTION SensorAlarmTest OPERATIONAL TEST HAZARD The sensoralarm test checks a sensor’s abilityto signal an Failure to follow this caution may result in personnel alarm state. Thistest requiresthat you use a fieldprovided and authority concern. SD--MAG test magnet. Pressing the controller’s test/reset switch for longer ! than seven seconds will put the duct detector into the CAUTION alarm state andactivate all automatic alarm responses. OPERATIONAL TEST HAZARD DirtyCont

Summary of the content on the page No. 20

ChangingtheDirtSensorTest 12 By default, sensor dirty test results are indicated by: Smoke Detector Controller 1 S The sensor’sDirtyLEDflashing. TB3 S The controller’sTrouble LEDflashing. − 1 Auxiliary equipment S The controller’ssupervisionrelaycontactstoggle. + 2 The operation of a sensor’s dirty test can be changed so 3 14 that the controller’s supervision relay is not used to SD-TRK4 indicate test results. When two detectors are connected to Supervision relay contacts [3] a controller, sens


Alternative user manuals
# User manual Category Download
1 Bryant 113A User manual Air Conditioner 365
2 Bryant 24B User manual Air Conditioner 61
3 Bryant 187B User manual Air Conditioner 39
4 Bryant 342S User manual Air Conditioner 17
5 Bryant 39479D8 User manual Air Conditioner 31
6 Bryant 342 User manual Air Conditioner 15
7 Bryant 165A User manual Air Conditioner 22
8 Bryant 450D User manual Air Conditioner 21
9 Bryant 451P User manual Air Conditioner 7
10 Bryant 451 User manual Air Conditioner 7
11 Bryant 36-453 User manual Air Conditioner 10
12 Bryant 452W User manual Air Conditioner 6
13 Bryant 452 User manual Air Conditioner 3
14 Bryant 454 User manual Air Conditioner 112
15 Bryant 463AAC008BA User manual Air Conditioner 17
16 Sony SU-PW2 User manual Air Conditioner 12
17 Sony CV-P12PX User manual Air Conditioner 3
18 Sony MULTI CHANNEL AV RECEIVER STR-DG710 User manual Air Conditioner 31
19 Sony VGN-BX500 User manual Air Conditioner 1
20 Philips 190S5 User manual Air Conditioner 21