Summary of the content on the page No. 1
INSTALLATION & OPERATION MANUAL FOR
Achiever Charbroilers
MODELS MLS
VACB20 ML-135285
VACB25 ML-710543
VACB36
ML-710544
MODELS MLS
VACB47 ML-710545
VACB60 ML-710546
ACB20 ML-135285
VACB72 ML-135286
ACB25 ML-710543
www.vulcanhart.com ACB36 ML-710544
ACB47 ML-710545
ACB60 ML-710546
ACB72 ML-135286
www.wolfrange.com
VACB47
ITW Food Equipment Group, LLC RETAIN THIS MANUAL FOR FUTURE USE
3600 North Point Blvd.
Baltimore, MD 21222 FORM F36950 (05-08)
Summary of the content on the page No. 2
IMPORTANT FOR YOUR SAFETY THIS MANUAL HAS BEEN PREPARED FOR PERSONNEL QUALIFIED TO INSTALL GAS EQUIPMENT, WHO SHOULD PERFORM THE INITIAL FIELD START-UP AND ADJUSTMENTS OF THE EQUIPMENT COVERED BY THIS MANUAL. POST IN A PROMINENT LOCATION THE INSTRUCTIONS TO BE FOLLOWED IN THE EVENT THE SMELL OF GAS IS DETECTED. THIS INFORMATION CAN BE OBTAINED FROM THE LOCAL GAS SUPPLIER. IMPORTANT IN THE EVENT A GAS ODOR IS DETECTED, SHUT DOWN UNITS AT MAIN SHUTOFF VALVE AND CONTACT THE LO
Summary of the content on the page No. 3
INSTALLATION, OPERATION AND CARE OF GAS COUNTERTOP CHARBROILERS GENERAL Gas Countertop Charbroilers are designed for commercial use only and feature fast, efficient gas heat. Each burner is controlled by an adjustable gas valve. Cast radiants are located directly above each burner to maintain uniform temperature. Radiants are easily removed for cleaning when cool. Heavy-duty, cast iron top grates are reversible to allow all or part of the cooking grid surface to be level or sloped
Summary of the content on the page No. 4
supply connection(s). Provide 24" clearance at the front for cleaning, maintenance, service and proper operation. Minimum clearances to combustible construction are 12" to the back and 9" to the sides. Minimum clearances to non-combustible walls are 0" to the rear and 0" to the sides. INSTALLATION CODES AND STANDARDS The Charbroiler must be installed in accordance with: In the United States of America: 1. State and local codes. 2. National Fuel Gas Code, ANSI-Z223.1/NFPA #54 (latest e
Summary of the content on the page No. 5
LEVELING It is important that the charbroiler is level front to back and left to right. Areas of uneven heat distribution will occur on an unleveled unit. The charbroiler is equipped with adjustable legs. Turn the feet at the bottom of the legs to adjust to level. The unit should be rechecked for level anytime it has been moved. VENTILATION HOOD The broiler should be installed under a suitable ventilation hood. For safe operation and proper ventilation, keep the space between th
Summary of the content on the page No. 6
GAS PRESSURE REGULATOR INSTALLATION Gas regulator pressure is preset at 5” Water Column (W.C.) for natural gas, and 10” W.C. for propane gas. Minor adjustments may be required based on site specific gas pressure. Install the regulator as close to the broiler on the gas supply line as possible. Make sure that the arrow on the underside of the regulator is oriented in the direction of gas flow to the broiler (Fig. 2) and the regulator is positioned with the vent plug and adjustment screw
Summary of the content on the page No. 7
BURNER VALVES Fig. 2 All orifices are of the fixed type and require no adjustment. Standing pilots should be adjusted to provide a slight yellow tip on the flame. Pilots may be lighted by removing adjacent cast iron top grates and radiants. Air shutters on the main burners must be individually adjusted to provide a blue flame. All traces of yellow should be adjusted out of the burner flame. While making adjustments, you may notice that some burners, especially to the far right and
Summary of the content on the page No. 8
COMPONENT PARTS The Achiever Charbroiler comes with several standard parts as illustrated. Each can be easily removed and installed easily by hand for cleaning and maintenance. Note that the Burner and Deflector are an assembly and are NOT designed to be disassembled. You will find that the two of the Burner- Deflector assemblies on the extreme right and left of your charbroiler have Deflectors that are flat, and not bent as shown. For correct operation ensure that the flat Burner-D
Summary of the content on the page No. 9
ACCESSORIES STANDS The charbroiler has an optional 24” high by 30” deep by 24”, 36”, 48”, 60” or 72” wide stainless steel stand with casters or flanged legs. The front casters lock, and flanged legs may be bolted to the floor. The stand includes a top shelf with marine edges style lip and a lower shelf. When mounted on a stand with standard legs and properly leveled, the cooking surface should be approximately 36” from the floor. GRATES The charbroiler has a variety of optional grate acc