Bryant 581C024--060 user manual

User manual for the device Bryant 581C024--060

Device: Bryant 581C024--060
Category: Air Conditioner
Manufacturer: Bryant
Size: 2.55 MB
Added : 11/14/2014
Number of pages: 60
Print the manual

Download

How to use this site?

Our goal is to provide you with a quick access to the content of the user manual for Bryant 581C024--060. Using the online preview, you can quickly view the contents and go to the page where you will find the solution to your problem with Bryant 581C024--060.

For your convenience

If looking through the Bryant 581C024--060 user manual directly on this website is not convenient for you, there are two possible solutions:

  • Full Screen Viewing - to easily view the user manual (without downloading it to your computer), you can use full-screen viewing mode. To start viewing the user manual Bryant 581C024--060 on full screen, use the button Fullscreen.
  • Downloading to your computer - You can also download the user manual Bryant 581C024--060 to your computer and keep it in your files. However, if you do not want to take up too much of your disk space, you can always download it in the future from ManualsBase.
Bryant 581C024--060 User manual - Online PDF
Advertisement
« Page 1 of 60 »
Advertisement
Print version

Many people prefer to read the documents not on the screen, but in the printed version. The option to print the manual has also been provided, and you can use it by clicking the link above - Print the manual. You do not have to print the entire manual Bryant 581C024--060 but the selected pages only. paper.

Summaries

Below you will find previews of the content of the user manuals presented on the following pages to Bryant 581C024--060. If you want to quickly view the content of pages found on the following pages of the manual, you can use them.

Abstracts of contents
Summary of the content on the page No. 1

581B036--072
581C024--060
SINGLE--PACKAGE ROOFTOP HEATING/COOLING
STANDARD AND LOW NOx UNITS
Installation Instructions
TABLE OF CONTENTS literature, tags and labels attached to the unit, and other safety
precautionsthat may apply.
Page
Followallsafetycodes.Wearsafetyglassesandwork gloves.Use
SAFETY CONSIDERATIONS ........................ 1
quenchingclothforunbrazing operations.Havefireextinguishers
INSTALLATION .................................. 1
availableforallbrazing operations.
Step1--Provid

Summary of the content on the page No. 2

A minimum clearance is not required around ductwork. Cabinet return-air static pressure (a negative condition) shall not exceed 0.35 in.wg with economizeror0.45 in.wg withouteconomizer. These units are designed for a minimum continuous return-air temperature in heating of 50_F (dry bulb), or an intermittent operation down to 45_F (dry bulb), such as when used with a night setback thermostat. To operate at lower return-air temperatures, a field-supplied outdoor air temperature control must be use

Summary of the content on the page No. 3

DALT ROOF CURB UNIT CONNECTOR ACCESSORY A BC DRAIN GAS POWER CONTROL ACCESSORY SIZE PKG. ACCY. POWER HOLE 1 -2 CRRFCURB001A01 3 3 CRBTMPWR001A01 / [19] NPT / 4 [356] 4 581B036-072 [19] NPT 1 CRBTMPWR002A01 1 / [31.7] 4 2 -0 581C024-060 CRRFCURB002A01 11 3 1 1 1 -9 / 1 -4 1 / 1 / / 16 4 / 2 2 [610] 2 3 CRBTMPWR003A01 / [19] NPT 4 [551] [406] [44.5] [12.7] [12.7] [12.7] NPT 3 /4 1 NOTES: CRBTMPWR004A01 1 / [31.7] 4 [19] NPT 1. Roof curb accessory is shipped disassembled. 2. Insulated panels. 3

Summary of the content on the page No. 4

MAXIMUM ALLOWABLE DIFFERENCE (in.) CONDENSATE PAN (SIDE VIEW) A-B B-C A-C HORIZONTAL 0.5 1.0 1.0 DRAIN PLUG DRAIN OUTLET NOTE: Drain plug is shown in factory-installed position. C06003 Fig.4 --- CondensateDrainPan C06110 Fig.3 --- UnitLeveling Tolerances Be sure that unit is installed such that snow will not block the combustion intakeor flueoutlet. Unit maybeinstalleddirectly onwood flooringor onClassA,B, orC roof-covering materialwhen roofcurb isused. Although unit is weatherproof, guard again

Summary of the content on the page No. 5

NOTES: 1. Place unit on curbasclose aspossible to the duct end. 2. Dimensionin( )isinmillimeters. 3. Hookriggingshacklesthrough holesin base rail asshown in detail “A.”Holesin base railsare centeredaroundthe unitcenter of gravity.Use wooden topskid when riggingto preventriggingstrapsfromdamagingunit. 4. Weightsinclude base unitwithouteconomizer.See Table 1for unitoperatingweightswith accessory economizer. 5. Weightsinclude base unitwithoutthe PerfectHumidityt adaptive dehumidification system. Se

Summary of the content on the page No. 6

6 581B,C COMPRESSOR ACCESS PANEL CONTROL BOX C06363 Fig.8 --- 581B036--072BaseUnitDimensions

Summary of the content on the page No. 7

7 C06364 Fig.9 --- 581C024--060BaseUnitDimensions 581B,C COMPRESSOR ACCESS PANEL

Summary of the content on the page No. 8

FieldPowerSupply Allunitsexcept 208/230-v units arefactory wired for thevoltage shown on thenameplate. Ifthe 208/230-v unit isto beconnected to a 208-v power supply, the transformer must be rewired by moving the black wire from the 230-v terminal on the transformer and connecting it to the 200-v terminal from the transformer. Refer to unit label diagram for additional information. Pigtails are provided for field service. Use factory-supplied splices orUL (Underwriters’Laboratories)approved coppe

Summary of the content on the page No. 9

Table1—PhysicalData581B BASEUNIT581B 036 048 060 072 NOMINAL CAPACITY(tons) 3 4 5 6 OPERATING WEIGHT(lb) Unit 530 540 560 635 Perfect Humidity™ Adaptive Dehumidification System 15 23 25 29 EconoMi$er IV 50 50 50 50 Roof Curb 115 115 115 115 COMPRESSOR Scroll Quantity 1 1 1 1 Oil (oz) 42 53 50 60 REFRIGERANTTYPE R-22 Expansion Device Acutrol™ MeteringDevice Operating Charge (lb-oz) StandardUnit 5-8 10-2 10-0 12- 8 Unit With Perfect Humidity Adaptive Dehumidification System 12-5 18-8 20-5 23-14 CO

Summary of the content on the page No. 10

Table1—PhysicalData581B(cont) UNITSIZE581B 036 048 060 072 FURNACESECTION RolloutSwitch CutoutTemp(F)† 195 195 195 195 Burner Orifice Diameter (in. ...drill size)** Natural Gas—Std 071/072 .113...33 .113...33 .113...33 .113...33 114/115 .113...33 .113...33 .113...33 .113...33 149/150 — .129...30 .129...30 .129...30 060N .102...38 .102...38 .102...38 — 090N .102...38 .102...38 .102...38 — 120N — .116...32 .116...32 — Propane —Alt†† 071/072 .089...43 .089...43 .089...43 .089...43 114115 .089...43

Summary of the content on the page No. 11

Table2—PhysicalData581C BASEUNIT581C 024 036 048 072 NOMINAL CAPACITY(tons) 2 3 4 5 OPERATING WEIGHT(lb) Unit 530 540 560 635 Perfect Humidity™ Adaptive Dehumidification System 13 15 23 25 EconoMi$er IV 50 50 50 50 Roof Curb 115 115 115 115 COMPRESSOR Scroll Quantity 1 1 1 1 Oil (oz) 25 42 56 53 REFRIGERANTTYPE R-22 Expansion Device Acutrol™ MeteringDevice Operating Charge (lb-oz) StandardUnit 5---3 7---11 8---8 12---11 Unit With Perfect Humidity Adaptive Dehumidification System 10---2 14---0 14

Summary of the content on the page No. 12

Table2—PhysicalData581C(cont) UNITSIZE581C 024 036 048 060 FURNACESECTION RolloutSwitch CutoutTemp(F)† 195 195 195 195 Burner Orifice Diameter (in. ...drill size)** Natural Gas—Std 071/072 .113...33 .113...33 .113...33 .113...33 114/115 .113...33 .113...33 .113...33 .113...33 149/150 — .129...30 .129...30 .129...30 060N .102...38 .102...38 .102...38 — 090N .102...38 .102...38 .102...38 — 120N — .116...32 .116...32 — Propane —Alt†† 071/072 .089...43 .089...43 .089...43 .089...43 114115 .089...43

Summary of the content on the page No. 13

TO COMP BLK BLK TO COMP BLK 11 23 11 23 YEL BLU 11 23 YEL YEL BLU C C C 21 23 21 23 21 23 EQUIP GND FIELD POWER SUPPLY DISCONNECT 575-3-60 FIELD POWER SUPPLY PER NEC FIELD POWER SUPPLY (SIZES 581B036,048 208/230-3-60 581C036,048) DISCONNECT DISCONNECT 208/230-1-60 480-3-60 PER NEC PER NEC (SIZES 581B036-060, (SIZES 581B036,048 581C024-060) 581C036,048) TO COMP BLK BLK TO TB2 11 23 11 13 YEL YEL BLU C C BLU 21 23 21 23 14 IFC 3 6 FIELD POWER SUPPLY DISCONNECT 575-3-60 PER NEC FIELD POWER SUPPLY (

Summary of the content on the page No. 14

14 581B,C Table3—ElectricalData581C VOLTAGE COMBUSTION CONV MINIMUMUNIT COMPRESSOR OFM 581C024---060 POWERSUPPLY* RANGE FANMOTOR IIFM FM OUTLET DISCONNECTSIZE NOMINAL FLA UNITSIZE IFMTYPE Min Max QTY RLA LRA QTY FLA FLA MCA FLA LRA MOCP** V---PH---Hz 024 024 NO 16.3 20 15.6 69 2 20 08 8//2 23 30 0--- ---1 1--- ---6 60 0 S ST TD D 1 18 87 7 2 25 54 4 1 1 1 10 0.9 9 6 63 3 1 1 0 0.7 7 0 0.6 6 2 2.0 0 (2tons) YES 22.3 25 21.2 73 NO 25.6 30 24.8 101 208 208//2 23 30 0------1 1------6 60 0 S STD TD 1

Summary of the content on the page No. 15

15 Table4—ElectricalData581B VOLTAGE COMBUSTION IFM CONV MINIMUMUNI 581B036---072 COMPRESSOR(each) OFM(each) POWERSUPPLY* RANGE FANMOTOR FLA OUTLET DISCONNECTSIZE NOMINAL UNITSIZE IFMTYPE Min Max QTY RLA LRA QTY FLA FLA MCA FLA LRA MOCP** V---PH---Hz NO 25.6 30 25 101 2 208 08//2 23 30 0------1 1------6 60 0 S STD TD 1 187 87 254 254 1 1 1 16 6 88 88 1 1 0 0.7 7 0 0.6 6 4 4.9 9 YES 31.6 35 30 106 NO 18.5 25 18 90 S STD TD 4 4.9 9 YES 24.5 30 24 95 208 208//230 230------3 36 60 0 187 187 254 254

Summary of the content on the page No. 16

To install Thermidistat device: Step8—AdjustFactory--InstalledOptions 1. Route Thermidistat cable through hole provided in unit PerfectHumidity™AdaptiveDehumidification controlbox. System 2. Some models may be equipped with a raceway built into Perfect Humidity system operation can be controlled by field thecorner postlocated on the leftside ofcontrol box (See installation ofaBryant--approved humidistat. (SeeFig.15.) Fig. 14). This raceway provides the required clearance NOTE: A light commercial

Summary of the content on the page No. 17

LEGEND CB — Circuit Breaker Terminal (Unmarked) CR — Cooling Relay DHR — Dehumidify Relay Splice DSV — Discharge Solenoid Valve HR — Heater Relay Factory Wiring LPS — Low Pressure Switch Field Control Wiring LSV — Liquid Solenoid Valve LTLO — Low Temperature Lockout Field Power Wiring Field Splice C06128 Fig.17 --- TypicalPerfectHumidityt AdaptiveDehumidification System HumidistatWiring(208/230--VUnitShown) LCT ROOF TOP UNIT R R C C Y1 Y1 Y2 Y2 G G W1 W1 W2 W2 CB R1 DEHUM 3.2 AMPS OC PINK RED 2

Summary of the content on the page No. 18

OptionalEconomi$erIV SeeFig.23 forEconoMi$erIV componentlocations. NOTE: These instructions are for installing the optional EconoMi$er IV. Refer to the accessory EconoMi$er IV when field installing an EconoMi$erIV accessory. 1. To remove the existing unit filter access panel, raise the panel and swing the bottom outward. The panel is now disengaged from the track and can be removed. (See Fig.24.) 2. Theboxwith theeconomizerhoodcomponentsisshipped in the compartment behind the economizer. The Eco

Summary of the content on the page No. 19

SupplyAirTemperature(SAT)Sensor The supply air temperature sensor is a 3k ohm thermistorlocated at the inlet of theindoor fan.(See Fig.34.) Thissensor isfactory installed. The operating range of temperature measurement is 0° to 158_F. SeeTable5 for sensor temperature/resistancevalues. HOOD BOX BRACKET Table5—SupplyAirSensorTemperature/ ResistanceValues TEMPERATURE(F) RESISTANCE(ohms) –58 200,250 –40 100,680 –22 53,010 –4 29,091 14 16,590 32 9,795 C06024 50 5,970 Fig.25 --- HoodBoxRemoval 68 3,74

Summary of the content on the page No. 20

Economi$erIVControlModes DifferentialDryBulbControl Determine the EconoMi$er IV control mode before set up of the For differential dry bulb control the standard outdoor dry bulb control. Some modes of operation may require different sensor is used in conjunction with an additional accessory dry sensors. (See Table 6.) The EconoMi$er IV is supplied from the bulb sensor (part number CRTEMPSN002A00). The accessory factory with a supply--air temperature sensor and an outdoor-- air sensor must be mou


Alternative user manuals
# User manual Category Download
1 Bryant 113A User manual Air Conditioner 365
2 Bryant 24B User manual Air Conditioner 61
3 Bryant 187B User manual Air Conditioner 39
4 Bryant 342S User manual Air Conditioner 17
5 Bryant 39479D8 User manual Air Conditioner 31
6 Bryant 342 User manual Air Conditioner 15
7 Bryant 165A User manual Air Conditioner 22
8 Bryant 450D User manual Air Conditioner 21
9 Bryant 451P User manual Air Conditioner 7
10 Bryant 451 User manual Air Conditioner 7
11 Bryant 36-453 User manual Air Conditioner 10
12 Bryant 452W User manual Air Conditioner 6
13 Bryant 452 User manual Air Conditioner 3
14 Bryant 454 User manual Air Conditioner 112
15 Bryant 463AAC008BA User manual Air Conditioner 17
16 Sony SU-PW2 User manual Air Conditioner 12
17 Sony CV-P12PX User manual Air Conditioner 3
18 Sony MULTI CHANNEL AV RECEIVER STR-DG710 User manual Air Conditioner 31
19 Sony VGN-BX500 User manual Air Conditioner 1
20 Philips 190S5 User manual Air Conditioner 21