Ariston E-COMBI 24 30 38 user manual

User manual for the device Ariston E-COMBI 24 30 38

Device: Ariston E-COMBI 24 30 38
Category: Boiler
Manufacturer: Ariston
Size: 6.55 MB
Added : 7/31/2014
Number of pages: 56
Print the manual

Download

How to use this site?

Our goal is to provide you with a quick access to the content of the user manual for Ariston E-COMBI 24 30 38. Using the online preview, you can quickly view the contents and go to the page where you will find the solution to your problem with Ariston E-COMBI 24 30 38.

For your convenience

If looking through the Ariston E-COMBI 24 30 38 user manual directly on this website is not convenient for you, there are two possible solutions:

  • Full Screen Viewing - to easily view the user manual (without downloading it to your computer), you can use full-screen viewing mode. To start viewing the user manual Ariston E-COMBI 24 30 38 on full screen, use the button Fullscreen.
  • Downloading to your computer - You can also download the user manual Ariston E-COMBI 24 30 38 to your computer and keep it in your files. However, if you do not want to take up too much of your disk space, you can always download it in the future from ManualsBase.
Ariston E-COMBI 24 30 38 User manual - Online PDF
Advertisement
« Page 1 of 56 »
Advertisement
Print version

Many people prefer to read the documents not on the screen, but in the printed version. The option to print the manual has also been provided, and you can use it by clicking the link above - Print the manual. You do not have to print the entire manual Ariston E-COMBI 24 30 38 but the selected pages only. paper.

Summaries

Below you will find previews of the content of the user manuals presented on the following pages to Ariston E-COMBI 24 30 38. If you want to quickly view the content of pages found on the following pages of the manual, you can use them.

Abstracts of contents
Summary of the content on the page No. 1


E-Combi 24/30/38
E-System 24/30
CONDENSING WALL HUNG
COMBINATION BOILER
G.C.N : 47 - 116 - 62 (24 kW)
G.C.N : 47 - 116 - 63 (30 kW)
G.C.N : 47 - 116 - 64 (38 kW)
CONDENSING WALL HUNG
O.H. BOILER
G.C.N : 41 - 116 - 34 (24 kW)
G.C.N : 41 - 116 - 35 (30 kW)
Country of destination GB, IE

Summary of the content on the page No. 2

INDEX Overview ..........................................................................................3 Maintenance ..................................................................................33 General Information ............................................................................................. 3 General Comments .............................................................................................33 Advice for the Installer ..........................................

Summary of the content on the page No. 3

overview These instructions are suitable for E-COMBI and E-SYSTEM boilers : Do not forget to complete the Benchmark Commisioning Checklist. The Benchmark Scheme Benchmark places responsibilities on both manufacturers and installers. The purpose is to ensure that customers are provided with the correct equipment for their needs, that it is installed, commissioned and serviced in accordance with the manufacturer’s instructions by competent persons and that it meets the requirements of the appr

Summary of the content on the page No. 4

overview Advice for the installer Symbols used on the data plate The installation and fi rst ignition of the boiler must be performed by qualifi ed personnel in compliance with current 2 national regulations regarding installation, and in conformity 1 with any requirements established by local authorities and public health organisations. 4 3 5 After the boiler has been installed, the installer must ensure that the end user receives the declaration of conformity and the 6 operating manua

Summary of the content on the page No. 5

overview Safety regulations Key to symbols: Failure to comply with this warning implies the risk of personal injury, in some circumstances even fatal. Failure to comply with this warning implies the risk of damage, in some circumstances even serious, to property, plants or animals. During all work carried out at a certain height (generally Install the appliance on a solid wall which is not subject to with a diff erence in height of more than two metres), make vibration. sure that parapets

Summary of the content on the page No. 6

product description Control panel E-COMBI 1 60° 70° 50° 80° 40° 90° 10 2 9 3 8 on/off 7 I 4 O 6 5 E-SYSTEM 1 60° 70° 50° 80° 40° 90° 10 2 9 3 8 on/off 4 5 Legend : 1. Green indicator : CH temperature and error indicator 2. ON/OFF button 3. Green indicator : ON/OFF 4. Pressure gauge 5. Winter / Summer switch - Heating temperature regulation knob 6. Domestic Hot Water adjustment knob (E-Combi models) 7. Time clock (E-Combi models) 8. Green indicator : fl ame ON R

Summary of the content on the page No. 7

product description Overall view E-COMBI E-SYSTEM 1 22 1 22 2 2 21 21 3 3 20 20 19 19 4 4 18 18 5 5 6 17 6 17 7 7 16 16 15 8 14 14 9 9 10 13 12 10 12 11 11 1. F lue c onnec t or 13. D.H.W. Flow switch 2. Manual air vent 14. Circulation pump with auto air vent 3. Burner 15. Diverter valve 4. Detection electrode 16. Low water pressure switch 5. C.H. Return temperature probe 17. Silencer (according to model) 6. C.H. Flow temperature probe 18. Modulating fan 7. Gas valve 19. Ignition

Summary of the content on the page No. 8

product description Overall Dimensions Minimum clearances In order to allow easy access to the boiler for maintenance operations, the boiler must be installed in accordance with the clearances stated E-COMBI to the left (opposite). 200 200 120 120 180 55 450 150 65 65 67 67 315 mod. 24 385 mod. 30/35 E-SYSTEM 200 200 120 120 180 150 315 mod. 24 132 132 385 mod. 30 A. Central Heating Flow B. Domestic Hot Water Outlet C. Gas Inlet D. Domestic Cold Water Inlet E. Central Heatin

Summary of the content on the page No. 9

product description Technical Data Model E-COMBI 24 30 38 CE C er tifi cation (pin) 0085BR0347 Boiler t ype B23-B33-C13-C33-C43-C53-C83 Max/min nominal calorifi c fl ow rate (Pci) Qn kW 22.0/5.5 28.0/6.5 31.0/7.5 M ax/min nominal calorifi c fl ow rate (Pcs) Qn kW 24.4/6.1 31.1/7.2 34.4/8.3 Domestic hot wat er max/min nominal calorifi c fl ow rate (Pci) Qn kW 25.0/5.5 30.0/6.5 38.0/7.5 Domestic hot wat er max/min nominal calorifi c fl ow rate (Pcs) Qn kW 27.8/6.1 33.3/7.2 42.2/8.3 M ax/min

Summary of the content on the page No. 10

product description Model E-SYSTEM 24 30 CE C er tifi cation (pin) 0085BR0347 Boiler t ype B23-B33-C13-C33-C43-C53-C83 M ax/min nominal calorifi c fl ow rate (Pci) Qn kW 22.0/5.5 28.0/6.5 Max/min nominal calorifi c fl ow rate (Pcs) Qn kW 24.4/6.1 31.1/7.2 M ax/min power output (80°C-60°C) Pn kW 21.6/5.2 27.4/6.2 M ax/min power output (50°C-30°C) Pn kW 23.5/5.8 29.5/6.9 C ombustion effi ciency (of fl ue gas) % 97.9 97.9 Nominal calorifi c fl ow rate effi ciency (60/80°C) Hi/Hs % 98.0/88

Summary of the content on the page No. 11

installation Flue Reference Standards Detailed information on fl ue assembly can be found in the In the United Kingdom, the installation and initial start-up of the boiler must be by a Gas Safe registered installer in accordance with “Connecting the Flue” section. The boiler must be installed so that the fl ue terminal is exposed to the the installation standards currently in eff ect, as well as with any and free passage of external air at all times and must not be installed in all local he

Summary of the content on the page No. 12

installation Flushing and Water Treatment Location The boiler is equipped with a stainless steel heat exchanger. The boiler can be installed on any suitable internal wall (suitable The detailed recommendations for water treatment are given in BS sound proofi ng may be required when installing onto a stud partition 7593:1992 (Treatment of water in domestic hot water central heating wall). Provision must be made to allow for the correct routing of the systems); the following notes are given fo

Summary of the content on the page No. 13

installation Condensate Discharge 2. External termination of condensate drainage pipe via internal The condensate discharge hose from the boiler must have a discharge branch (e.g. sink waste) and condensate trap. o continuous fall of 2.5 and must be inserted by at least 50mm into a suitable acid resistant pipe - e.g. plastic waste or overfl ow pipe. The condensate discharge pipe must have a minimum diameter of 22mm, must have a continuous fall and preferably be installed and terminated t

Summary of the content on the page No. 14

installation Installing the Boiler Connecting the boiler to the system Please check that you are familiar with the installation requirement - Remove the boiler casing as described on page 16 before commencing work (pages 7 - 13). - Remove the caps and connect the valves to the boiler using the The installation accessories described in the following list are included washers provided in the boiler packaging: - 4 x fi bre washers for the CH fl ow and return, cold water inlet and hot - Hanging

Summary of the content on the page No. 15

installation Safety Valve Discharge and Condense Outlet G as connection The pressure relief valve pipe is made of copper. It should terminate Make sure, using the labels on the packaging and the data plate on below the boiler safely outside the premises. Care should be taken the appliance itself, that the boiler is in the correct country and that that it does not terminate over an entrance or window or where a the gas category for which the boiler was designed corresponds to discharge of h

Summary of the content on the page No. 16

installation Instructions for opening the casing and performing an To calculate the size of the heating installation, refer to the "Available internal inspection pressure" graph below. Before performing any work on the boiler, fi rst disconnect it from the Graph representing the available circulation pump o electrical power supply using the external bipolar switch; removing pressure ΔT20 C the fuse and shutting off the gas cock. mbar To access the inside of the boiler, the following is ne

Summary of the content on the page No. 17

4 4 5 5 installation Water circuit diagram E-SYSTEM E-COMBI 1 1 19 19 2 2 18 18 3 3 17 17 16 16 15 15 6 7 7 14 14 13 8 8 9 9 12 10 11 10 11 1. Manual air vent 2. Burner 3. Detection electrode 4. C.H. fl ow temperature probe 5. C.H. return temperature probe 6. Secondary heat exchanger 7. C.H. pressure relief valve 8. By-pass 9. Drain valve 10. Condensate trap 11. C.H. circuit fi lter 12. D.H.W. Flow switch 13. Diverter valve 14. Low water pres switch 15. Circulation pump

Summary of the content on the page No. 18

installation Connecting the Flue F lue S y st em The provision for satisfactory fl ue termination must be made as described in BS 5440-1. The appliance must be installed so that the fl ue terminal is exposed to outdoor air. The terminal must not discharge into another room or space such as an outhouse or lean-to. It is important that the position of the terminal allows a free passage of air across it at all times. The terminal should be located with due regard for the damage or discolourat

Summary of the content on the page No. 19

150 mm installation Fitting the Coaxial Flue Fig. 3 (Ø 60 / 100 Horizontal) C o nt ents: 1x Silicone O-Ring (60mm) 1x Elbow (90°) 2x Wall Seals (Internal & External) 1x Flue Pipe including Terminal (1 metre - 60/100) 2x Flue Clamps Installation without extension 4x Screws 2x Seals Level Once the boiler has been positioned on the wall, fi t the rubber fl ue seal into the internal fl ue turret (see diagram opposite), insert the elbow into the socket and rotate to the required position. 150 m

Summary of the content on the page No. 20

installation Fitting the 5” Flue (Ø 80 / 125 Horizontal/vertical) Onc e the boiler has been positioned on the wall, it is necessary to in- sert the Ø80/125 adaptor (Fig. 5) for both horizontal and vertical fl ue runs into the boiler fl ue socket (not supplied with fl ue kit - Part No 3318095). Push the adaptor onto the boiler’s fl ue connection, grease the seals Useable length of then add extensions or elbows as required, secure the adaptor, using Total length of vertical flue 575 mm* verti


Alternative user manuals
# User manual Category Download
1 Ariston 47-116-51 User manual Boiler 711
2 Ariston 28 MFFI User manual Boiler 162
3 Ariston Benchmark System A 30 RFF User manual Boiler 100
4 Ariston 47-116-15 User manual Boiler 116
5 Ariston 41-116-07 User manual Boiler 88
6 Ariston 47-116-53 User manual Boiler 22
7 Ariston EURO COMBI 47-116-10 User manual Boiler 16
8 Ariston Benchmark System A 24 RFF User manual Boiler 16
9 Ariston EURO COMBI A/23 MFFI User manual Boiler 339
10 Ariston EURO COMBI A/27 MFFI User manual Boiler 22
11 Ariston EURO COMBI 47-116-12 User manual Boiler 29
12 Ariston 31 MFFI User manual Boiler 11
13 Ariston 24 MFFI User manual Boiler 147
14 Ariston 28 MFFI User manual Boiler 49
15 Ariston 32 MFFI User manual Boiler 23
16 Sony HDV 1080I HVR-M15N/M15P User manual Boiler 67
17 Sony HDV 1080I HVR-M25N/M25P User manual Boiler 50
18 A.O. Smith 200 User manual Boiler 2
19 A.O. Smith 201 User manual Boiler 7
20 A.O. Smith 750 & 1000 User manual Boiler 6