Weil-McLain STAR-34 user manual

User manual for the device Weil-McLain STAR-34

Device: Weil-McLain STAR-34
Category: Boiler
Manufacturer: Weil-McLain
Size: 0.22 MB
Added : 7/31/2014
Number of pages: 8
Print the manual

Download

How to use this site?

Our goal is to provide you with a quick access to the content of the user manual for Weil-McLain STAR-34. Using the online preview, you can quickly view the contents and go to the page where you will find the solution to your problem with Weil-McLain STAR-34.

For your convenience

If looking through the Weil-McLain STAR-34 user manual directly on this website is not convenient for you, there are two possible solutions:

  • Full Screen Viewing - to easily view the user manual (without downloading it to your computer), you can use full-screen viewing mode. To start viewing the user manual Weil-McLain STAR-34 on full screen, use the button Fullscreen.
  • Downloading to your computer - You can also download the user manual Weil-McLain STAR-34 to your computer and keep it in your files. However, if you do not want to take up too much of your disk space, you can always download it in the future from ManualsBase.
Weil-McLain STAR-34 User manual - Online PDF
Advertisement
« Page 1 of 8 »
Advertisement
Print version

Many people prefer to read the documents not on the screen, but in the printed version. The option to print the manual has also been provided, and you can use it by clicking the link above - Print the manual. You do not have to print the entire manual Weil-McLain STAR-34 but the selected pages only. paper.

Summaries

Below you will find previews of the content of the user manuals presented on the following pages to Weil-McLain STAR-34. If you want to quickly view the content of pages found on the following pages of the manual, you can use them.

Abstracts of contents
Summary of the content on the page No. 1

GOLD GOLD GV GV
GOLD GV
GOLD GOLD GV GV
W Water boiler — Series 3 ater boiler — Series 3
W W Water boiler — Series 3 ater boiler — Series 3 ater boiler — Series 3
Venting Supplement
StaR StaR StaR-34 -34 -34
StaR StaR-34 -34
Special gas vent system vent and combustion Special gas vent system vent and combustion Special gas vent system vent and combustion Special gas vent system vent and combustion Special gas vent system vent and combustion
air supplement air supplement air supplement

Summary of the content on the page No. 2

GOLD GV Water boiler — Series 3 Combustion air supply Special note Refer to GV Series 3 Boiler Manual for sizing free area of combustion/ventilation air openings. All boilers experience some condensation in section assembly during start-up. Unlike most conventional boilers, condensation is minimized in the GV Series 3 Boiler by a built-in mixing 0 system, maintaining boiler return water temperature above 130 F, during steady state operation. Flue gas condensate is slightly acidic. In most cases

Summary of the content on the page No. 3

StaR-34 Venting Supplement Vent termination Venting method definitions anticipated snow line. In addition, vent termination must be at least 7 feet above public walkway and 3 feet above any forced Direct vent — Uses outside combustion air with combustion air intake within 10 feet. Stay well away from trees, shrubs, air connector piping sealed at all joints and seams. Also known as and decorative items. Site conditions may dictate greater “sealed combustion”. clearances. See Figure 1. Non-Direct

Summary of the content on the page No. 4

GOLD GV Water boiler — Series 3 Installation Pre-installation planning 1. Follow national, state, local or provincial codes or step 2. Vent and combustion air connector piping regulations when venting GV boiler. configurations must match. Use suitable 3" material for combustion air connector piping, such as: 2. Choose vent method from those shown on page 5.  Dryer vent 3. Select vent run components from Table 2. Table 3 states maximum vent run lengths and number of  Galvanized steel elbows. Do

Summary of the content on the page No. 5

Slope Slope StaR-34 Venting Supplement For altitudes more than 5,500 feet above sea level — Do not use non-direct vent through sidewall methods as shown in Figures 4 and 6 below. Can cause severe personal injury, death or substantial property damage if ignored. Select Figure 3 GV direct vent through sidewall Figure 4 GV non-direct vent through sidewall vent (using Weil-McLain Vent/Air Intake (using Weil-McLain Vent/Air Intake Termination Kit) Termination Kit) (See WARNING above.) method Slope ve

Summary of the content on the page No. 6

GOLD GV Water boiler — Series 3 Installation — assembly Connect vent starter Follow the instructions in the GV Series 3 Boiler Manual section II II II II IIb b b b b to connect the vent starter tee to the boiler. tee to boiler Follow vent pipe manufacturer's instructions for sealing the vent. Vent and Construct vent and combustion air connector piping must be sealed gas-tight to prevent optional possibility of flue gas spillage and carbon monoxide emissions, resulting in severe personal injury o

Summary of the content on the page No. 7

StaR-34 Venting Supplement Figure 8 Sidewall termination installation (non-direct venting) ¼" to ¾" between stop on termination and metal plate 4" galvanized sleeve (through 4¹⁄₈" hole for Pipe section combustible wall) Metal plate Metal plate Spacers (2) (to support and Pipe section center vent in Sealant sleeve) Sealant Termination coupling 26809 Figure 9 Non-direct vent through sidewall (using Figure 10 Non-Direct vent through roof Follow StaR-34 manufacturer’s instructions termination coupli

Summary of the content on the page No. 8

GOLD GV Water boiler — Series 3 Installation — assembly continued Finish the vent Installing condensate tubing Figure 11 installation 1. See Figure 11 to install condensate tubing Installation of condensate tubing (provided by others). Use condensate pump if floor drain is higher than condensate drain on boiler. StaR-34 If required: vent starter tee  use a low-profile pump — OR —  set boiler on foundation (see GV Series 3 Boiler Manual) to allow gravity flow to pump. 2. Size pump in gal/hr. (b


Alternative user manuals
# User manual Category Download
1 Weil-McLain 382-200-305 User manual Boiler 1
2 Weil-McLain 550-141-830/1202 User manual Boiler 1
3 Weil-McLain 94 User manual Boiler 0
4 Weil-McLain 550-141-829/1201 User manual Boiler 1
5 Weil-McLain 68 User manual Boiler 1
6 Weil-McLain 88 User manual Boiler 2
7 Weil-McLain 68V User manual Boiler 0
8 Weil-McLain 550-141-826/1201 User manual Boiler 0
9 Weil-McLain B-66HE User manual Boiler 0
10 Weil-McLain 88 Series User manual Boiler 0
11 Weil-McLain BCP-3 User manual Boiler 4
12 Weil-McLain BCP-8S User manual Boiler 0
13 Weil-McLain A-66E User manual Boiler 0
14 Weil-McLain AFG User manual Boiler 1
15 Weil-McLain BMC User manual Boiler 0
16 Sony HDV 1080I HVR-M15N/M15P User manual Boiler 67
17 Sony HDV 1080I HVR-M25N/M25P User manual Boiler 50
18 A.O. Smith 200 User manual Boiler 2
19 A.O. Smith 201 User manual Boiler 7
20 A.O. Smith 750 & 1000 User manual Boiler 6