Bryant 561C user manual

User manual for the device Bryant 561C

Device: Bryant 561C
Category: Air Conditioner
Manufacturer: Bryant
Size: 0.16 MB
Added : 11/14/2014
Number of pages: 28
Print the manual

Download

How to use this site?

Our goal is to provide you with a quick access to the content of the user manual for Bryant 561C. Using the online preview, you can quickly view the contents and go to the page where you will find the solution to your problem with Bryant 561C.

For your convenience

If looking through the Bryant 561C user manual directly on this website is not convenient for you, there are two possible solutions:

  • Full Screen Viewing - to easily view the user manual (without downloading it to your computer), you can use full-screen viewing mode. To start viewing the user manual Bryant 561C on full screen, use the button Fullscreen.
  • Downloading to your computer - You can also download the user manual Bryant 561C to your computer and keep it in your files. However, if you do not want to take up too much of your disk space, you can always download it in the future from ManualsBase.
Bryant 561C User manual - Online PDF
Advertisement
« Page 1 of 28 »
Advertisement
Print version

Many people prefer to read the documents not on the screen, but in the printed version. The option to print the manual has also been provided, and you can use it by clicking the link above - Print the manual. You do not have to print the entire manual Bryant 561C but the selected pages only. paper.

Summaries

Below you will find previews of the content of the user manuals presented on the following pages to Bryant 561C. If you want to quickly view the content of pages found on the following pages of the manual, you can use them.

Abstracts of contents
Summary of the content on the page No. 1



561C (60 Hz)
ELECTRIC
Sizes 018 thru 060
AIR CONDITIONER
Model 561C Energy-Efficient Air Conditioners incorporate inno-
vative technology to provide reliable summer cooling perfor-
mance. Built into these units are the features most desired by
homeowners today including SEER ratings of up to 11.5 when
used with components designated by manufacturer. All models
are listed with UL, c-UL, ARI, CEC, and CSA-EEV.
AVAILABLE OPTIONS
UNIT DESIGN—Copper tube, enhanced sine wave

Summary of the content on the page No. 2

DIMENSIONS—561C —2— A SQ AIR DISCHARGE AIR IN M AIR DISCHARGE FIELD POWER SUPPLY CONN 7 / -IN. DIA HOLE WITH 8 1 1 / -IN. DIA KNOCKOUT 8 3 AND 1 / -IN. DIA KNOCKOUT 8 N J K FIELD CONTROL SUPPLY AIR IN L 7 CONN / -IN. DIA HOLE 8 AIR IN B 3 /8-IN. DIA TIEDOWN 3 / -IN. DIA LIQUID 8 KNOCKOUTS LINE CONN (2) PLACES P C AIR DISCHARGE 7 2 /8″ E AIR IN 1 D DIA VAPOR LINE CONN 1 /4″ F G H NOTES: 1. Allow 30 in. clearance to service side of unit, 48 in. above unit, 6 in. o

Summary of the content on the page No. 3

H T G I N W I G N N O I I Y T L I P D M N O O C A C S R A I R I E S I R A Q T A A U O I N T P CHECK-FLO-RATER® PISTON CHART PISTON* UNIT SIZE IDENTIFICATION NO. 018-A, D 52 024-A, D 57 030-A, D 67 036-A, D, E 73 036-B 70 042-A, C 76 042-B 82 048-A, C 88 048-B 84 060-A, E 93 060-B 90 * Piston listed is for any approved coil non-capillary tube combination. Piston is shipped with outdoor unit and must be installed in an approved indoor coil. RECOMMENDED TUBE DIAMETERS Liquid Tu

Summary of the content on the page No. 4

SPECIFICATIONS UNIT SIZE-SERIES 561C018-A, D 561C024-A, D 561C030-A, D 561C030-A Operating Weight (Lb) 113/115 115/117 124/133 124 ELECTRICAL Unit Volts—Hertz—Phase 208-230—60—1 208/230—60—3 Operating Voltage Range* 197—253 187—253 Compressor— Rated Load Amps 9.6/9.0 10.7/11.6 14.2/14.8 9.4 Locked Rotor Amps 49.0/48.0 56.0/60.0 75.0/73.0 68.0 Condenser Fan Motor—Full Load Amps 0.8 1.0 0.8 0.8 Min Unit Ampacity for Wire Sizing 12.8/12.1 14.4/15.5 18.6/19.3 12.6 Min Wire Size (60°C C

Summary of the content on the page No. 5

SPECIFICATIONS Continued UNIT SIZE-SERIES 561C036-A, B, E 561C036-B, D 561C036-B 561C042-A, B 561C042-B, C 561C042-B Operating Weight (Lb) 129/138/138 129/133 133 138/142 142 ELECTRICAL Unit Volts—Hertz—Phase 208-230—60—1 208/230—60—3 460—60—3 208-230—60—1 208/230—60—3 460—60—3 Operating Voltage Range* 197—253 187—253 414—506 197—253 187—253 414—506 Compressor— Rated Load Amps 16.7/14.8/16.0 10.0/10.6 5.1 20.5/19.7 13.6/12.4 6.2 Locked Rotor Amps 95.0/8

Summary of the content on the page No. 6

SPECIFICATIONS Continued UNIT SIZE-SERIES 561C048-A, B 561C048-B, C 561C060-A, B 561C060-B, E Operating Weight (Lb) 192/198 233/218 ELECTRICAL Unit Volts—Hertz—Phase 208-230—60—1 208/230—60—3 460—60—3 208-230—60—1 208/230—60—3 460—60—3 Operating Voltage Range* 197—253 187—253 414—506 197—253 187—253 414—506 Compressor— Rated Load Amps 24.4/23.7 13.5/14.1 7.4/7.1 28.9/28.8 18.3/16.0 9.0/8.0 Locked Rotor Amps 140.0/129.0 120.0/105.0 49.5/52.5 165.0/169.0 137.0/125.0 6

Summary of the content on the page No. 7

* Permissible limits of the voltage range at which unit will operate satisfactorily. Operation outside these limits may result in unit failure. † If wire is applied at ambient greater than 30°C (86°F), consult Table 310-16 of the NEC (ANSI/NFPA 70). The ampacity of nonmetallic-sheathed cable (NM), trade name ROMEX, shall be that of 60°C (140°F) conductors, per the NEC (ANSI/NFPA 70) Article 336-26. If other than uncoated (non-plated), 60 or 75°C (140 or 167°F) insulatio

Summary of the content on the page No. 8

ACCESSORY DESCRIPTION AND USAGE (Listed Alphabetically) Continued 9. High-Pressure Switch Auto reset SPST switch activated by refrigerant pressure on high side of refrigerant circuit. Cycles compressor off if refrigerant pressure rises to 400 ± 10 psig and resets at 298 ± 20 psig. Provides protection against compressor damage due to loss of outdoor airflow. To prevent rapid compressor recycling, Cycle Protector can be used with this switch. SUGGESTED USE: Installa

Summary of the content on the page No. 9

COMBINATION RATINGS FACTORY- BRYANT GAS SUPPLIED FURNACE OR UNIT INDOOR TOT. CAP. ENHANCE- STANDARD ACCESSORY ACCESSORY SIZE-SERIES MODEL BTUH MENT RATING TXV‡ EERA TDR† CC5A/CD5AA018* 17,200 NONE — 10.00 10.00 9.20 CC5A/CD5AA024 17,600 NONE 10.00 10.50 10.50 9.45 CC5A/CD5AW024 17,600 NONE 10.00 10.50 10.50 9.45 CE3AA024 17,800 NONE 10.00 10.50 10.50 9.50 CF5AA024 17,800 NONE 10.00 10.50 10.50 9.50 CK3BA024 17,600 NONE 10.00 10.50 10.50 9.55 CK5A/CK5BA018 17,200 NONE — 10

Summary of the content on the page No. 10

COMBINATION RATINGS Continued FACTORY- BRYANT GAS SUPPLIED FURNACE OR UNIT INDOOR TOT. CAP. ENHANCE- STANDARD ACCESSORY ACCESSORY SIZE-SERIES MODEL BTUH MENT RATING TXV‡ EERA TDR† CD5A/CD5AA030* 28,000 NONE 10.00 10.10 10.10 9.10 CC5A/CD5AA036 29,000 NONE 10.00 10.10 10.10 9.30 CC5A/CD5AW030 28,000 NONE 10.00 10.10 10.10 9.10 CD5AW036 29,000 NONE 10.00 10.10 10.10 9.30 CE3AA030 27,800 NONE 10.00 10.10 10.10 9.15 CE3AA036 28,600 NONE 10.00 10.10 10.10 9.25 CF5AA036 28,80

Summary of the content on the page No. 11

COMBINATION RATINGS Continued FACTORY- BRYANT GAS SUPPLIED FURNACE OR UNIT INDOOR TOT. CAP. ENHANCE- STANDARD ACCESSORY ACCESSORY SIZE-SERIES MODEL BTUH MENT RATING TXV‡ EERA TDR† CK3BA036 33,800 NONE 10.00 10.20 10.20 9.20 CK3BA042 33,800 NONE 10.00 10.20 10.20 9.20 CK5A/CK5BA036 33,800 NONE 10.00 10.20 10.20 9.20 CK5A/CK5BA042 33,800 NONE 10.00 10.20 10.20 9.20 CK5A/CK5BN036 31,400 NONE 10.00 10.20 10.20 9.30 CK5A/CK5BN042 33,800 NONE 10.00 10.20 10.20 9.20 CK5A/CK5BT03

Summary of the content on the page No. 12

COMBINATION RATINGS Continued FACTORY- BRYANT GAS SUPPLIED FURNACE OR UNIT INDOOR TOT. CAP. ENHANCE- STANDARD ACCESSORY ACCESSORY SIZE-SERIES MODEL BTUH MENT RATING TXV‡ EERA TDR† CK5A/CK5BA042 33,400 TDR 10.80 — 10.80 10.00 CK5A/CK5BT042 33,400 TDR 10.80 — 10.80 10.00 CK5A/CK5BW036 33,400 TDR 10.50 — 10.50 9.95 COILS + 355MAV060120 VARIABLE-SPEED FURNACE 036-A, B, D, E CC5A/CD5AA042 33,400 TDR 10.80 — 10.80 9.90 CD5AW036 33,400 TDR 10.50 — 10.50 9.85 CK5A/CK5BA042 33,400 TDR 10.80 — 10.80 9.9

Summary of the content on the page No. 13

COMBINATION RATINGS Continued FACTORY- BRYANT GAS SUPPLIED FURNACE OR UNIT INDOOR TOT. CAP. ENHANCE- STANDARD ACCESSORY ACCESSORY SIZE-SERIES MODEL BTUH MENT RATING TXV‡ EERA TDR† COILS + 355MAV060100 VARIABLE-SPEED FURNACE CC5A/CD5AA042 40,000 TDR 10.50 — 10.50 9.45 CC5A/CD5AC048 40,000 TDR 10.70 — 10.70 9.45 CK3BA042 40,000 TDR 10.50 — 10.50 9.45 CK3BA048 40,000 TDR 10.70 — 10.70 9.45 CK5A/CK5BA042 40,000 TDR 10.50 — 10.50 9.45 042-A, B, C CK5A/CK5BA048 40,000 TDR 10.70 — 10.70 9.45 COILS +

Summary of the content on the page No. 14

COMBINATION RATINGS Continued FACTORY- BRYANT GAS SUPPLIED FURNACE OR UNIT INDOOR TOT. CAP. ENHANCE- STANDARD ACCESSORY ACCESSORY SIZE-SERIES MODEL BTUH MENT RATING TXV‡ EERA TDR† CK3BA048 45,500 TDR 10.50 — 10.50 9.30 CK3BA060 45,500 TDR 11.00 — 11.00 9.15 COILS + 355MAV060080 VARIABLE-SPEED FURNACE CK3BA048 45,500 TDR 10.50 — 10.50 9.30 CK3BA060 45,500 TDR 11.00 — 11.00 9.15 CK5A/CK5BA048 45,500 TDR 10.50 — 10.50 9.30 CK5A/CK5BA060 45,500 TDR 10.50 — 10.50 9.15 CK5A/CK5BX060 46,000 TDR 11.00

Summary of the content on the page No. 15

DETAILED COOLING CAPACITIES* CONDENSER ENTERING AIR TEMPERATURES °F EVAPORATOR AIR 75 85 95 105 115 125 Capacity Capacity Capacity Capacity Capacity Capacity Total Total Total Total Total Total MBtuh† MBtuh† MBtuh† MBtuh† MBtuh† MBtuh† Sys Sys Sys Sys Sys Sys CFM EWB Total Sens‡ KW** Total Sens‡ KW** Total Sens‡ KW** Total Sens‡ KW** Total Sens‡ KW** Total Sens‡ KW** 561C018-A, D Outdoor Section With CC5A/CD5AA018 Indoor Section 72 21.0 10.0 1.77 19.9 9.58 1.88 18.7 9.11 1.98 17.4 8.65 2.09 16.2

Summary of the content on the page No. 16

DETAILED COOLING CAPACITIES* Continued CONDENSER ENTERING AIR TEMPERATURES °F EVAPORATOR AIR 75 85 95 105 115 125 Capacity Capacity Capacity Capacity Capacity Capacity Total Total Total Total Total Total MBtuh† MBtuh† MBtuh† MBtuh† MBtuh† MBtuh† Sys Sys Sys Sys Sys Sys Total Sens‡ KW** Total Sens‡ KW** Total Sens‡ KW** Total Sens‡ KW** Total Sens‡ KW** Total Sens‡ KW** CFM EWB 561C024-A, D Outdoor Section With CC5A/CD5AA024 Indoor Section 72 27.2 13.2 2.34 25.8 12.6 2.46 24.3 12.0 2.57 22.7 11.5

Summary of the content on the page No. 17

DETAILED COOLING CAPACITIES* Continued CONDENSER ENTERING AIR TEMPERATURES °F EVAPORATOR AIR 75 85 95 105 115 125 Capacity Capacity Capacity Capacity Capacity Capacity Total Total Total Total Total Total MBtuh† MBtuh† MBtuh† MBtuh† MBtuh† MBtuh† Sys Sys Sys Sys Sys Sys CFM EWB Total Sens‡ KW** Total Sens‡ KW** Total Sens‡ KW** Total Sens‡ KW** Total Sens‡ KW** Total Sens‡ KW** 561C030-A, D Outdoor Section With CC5A/CD5AA030 Indoor Section 72 34.0 16.4 2.85 32.2 15.7 3.01 30.3 15.0 3.17 28.4 14.3

Summary of the content on the page No. 18

DETAILED COOLING CAPACITIES* Continued CONDENSER ENTERING AIR TEMPERATURES °F EVAPORATOR AIR 75 85 95 105 115 125 Capacity Capacity Capacity Capacity Capacity Capacity Total Total Total Total Total Total MBtuh† MBtuh† MBtuh† MBtuh† MBtuh† MBtuh† Sys Sys Sys Sys Sys Sys CFM EWB Total Sens‡ KW** Total Sens‡ KW** Total Sens‡ KW** Total Sens‡ KW** Total Sens‡ KW** Total Sens‡ KW** 561C036-A, B, D, E Outdoor Section With CC5A/CD5AA036 Indoor Section 72 41.3 20.5 3.41 39.1 19.6 3.61 36.8 18.8 3.81 34.

Summary of the content on the page No. 19

DETAILED COOLING CAPACITIES* Continued CONDENSER ENTERING AIR TEMPERATURES °F EVAPORATOR AIR 75 85 95 105 115 125 Capacity Capacity Capacity Capacity Capacity Capacity Total Total Total Total Total Total MBtuh† MBtuh† MBtuh† MBtuh† MBtuh† MBtuh† Sys Sys Sys Sys Sys Sys Total Sens‡ KW** Total Sens‡ KW** Total Sens‡ KW** Total Sens‡ KW** Total Sens‡ KW** Total Sens‡ KW** CFM EWB 561C036-A, B, D, E Outdoor Section With CC5A/CD5AA036 Indoor Section Continued 72 41.3 20.5 3.41 39.1 19.6 3.61 36.8 18.

Summary of the content on the page No. 20

DETAILED COOLING CAPACITIES* Continued CONDENSER ENTERING AIR TEMPERATURES °F EVAPORATOR AIR 75 85 95 105 115 125 Capacity Capacity Capacity Capacity Capacity Capacity Total Total Total Total Total Total MBtuh† MBtuh† MBtuh† MBtuh† MBtuh† MBtuh† Sys Sys Sys Sys Sys Sys CFM EWB Total Sens‡ KW** Total Sens‡ KW** Total Sens‡ KW** Total Sens‡ KW** Total Sens‡ KW** Total Sens‡ KW** 561C042-A, B, C Outdoor Section With CC5A/CD5AA042 Indoor Section 72 48.6 23.6 4.08 45.9 22.6 4.35 43.2 21.6 4.60 40.5 2


Alternative user manuals
# User manual Category Download
1 Bryant 113A User manual Air Conditioner 365
2 Bryant 24B User manual Air Conditioner 61
3 Bryant 187B User manual Air Conditioner 39
4 Bryant 342S User manual Air Conditioner 17
5 Bryant 39479D8 User manual Air Conditioner 31
6 Bryant 342 User manual Air Conditioner 15
7 Bryant 165A User manual Air Conditioner 22
8 Bryant 450D User manual Air Conditioner 21
9 Bryant 451P User manual Air Conditioner 7
10 Bryant 451 User manual Air Conditioner 7
11 Bryant 36-453 User manual Air Conditioner 10
12 Bryant 452W User manual Air Conditioner 6
13 Bryant 452 User manual Air Conditioner 3
14 Bryant 454 User manual Air Conditioner 112
15 Bryant 463AAC008BA User manual Air Conditioner 17
16 Sony SU-PW2 User manual Air Conditioner 12
17 Sony CV-P12PX User manual Air Conditioner 3
18 Sony MULTI CHANNEL AV RECEIVER STR-DG710 User manual Air Conditioner 31
19 Sony VGN-BX500 User manual Air Conditioner 1
20 Philips 190S5 User manual Air Conditioner 21