Weil-McLain EG-30 THRU -75 user manual

User manual for the device Weil-McLain EG-30 THRU -75

Device: Weil-McLain EG-30 THRU -75
Category: Boiler
Manufacturer: Weil-McLain
Size: 4.32 MB
Added : 10/27/2013
Number of pages: 24
Print the manual

Download

How to use this site?

Our goal is to provide you with a quick access to the content of the user manual for Weil-McLain EG-30 THRU -75. Using the online preview, you can quickly view the contents and go to the page where you will find the solution to your problem with Weil-McLain EG-30 THRU -75.

For your convenience

If looking through the Weil-McLain EG-30 THRU -75 user manual directly on this website is not convenient for you, there are two possible solutions:

  • Full Screen Viewing - to easily view the user manual (without downloading it to your computer), you can use full-screen viewing mode. To start viewing the user manual Weil-McLain EG-30 THRU -75 on full screen, use the button Fullscreen.
  • Downloading to your computer - You can also download the user manual Weil-McLain EG-30 THRU -75 to your computer and keep it in your files. However, if you do not want to take up too much of your disk space, you can always download it in the future from ManualsBase.
Weil-McLain EG-30 THRU -75 User manual - Online PDF
Advertisement
« Page 1 of 24 »
Advertisement
Print version

Many people prefer to read the documents not on the screen, but in the printed version. The option to print the manual has also been provided, and you can use it by clicking the link above - Print the manual. You do not have to print the entire manual Weil-McLain EG-30 THRU -75 but the selected pages only. paper.

Summaries

Below you will find previews of the content of the user manuals presented on the following pages to Weil-McLain EG-30 THRU -75. If you want to quickly view the content of pages found on the following pages of the manual, you can use them.

Abstracts of contents
Summary of the content on the page No. 1

EG-30 thru -75
PEG-30 thru -65
Gas-Fired Boilers – Series 4
Control  supplement  –  Standing  pilot
For additional information, refer to . . .
EG•PEG•EGH Boiler manual
for Natural or Propane gas
(tankless heater application optional)
This supplement must only be used by a qualified heating installer/service technician. Before installing, read all
instructions, including this supplement, the boiler manual and any related documents. Perform steps in the order giv

Summary of the content on the page No. 2

EG-30 EG-30 thru  thru 75 75    Series Series   4 4      and and PEG-30 PEG-30   thru   thru65   65Series  Series   4 4    Please read this page first! Hazard definitions The following defined terms are used throughout these instructions to bring attention to the presence of hazards of various risk levels or to important information concerning the life of the product. Indicates presence of hazards that will cause severe personal injury, death or substanti

Summary of the content on the page No. 3

Standing Pilot Boilers — ControlSupplement   Table of contents Hazard definitions and Note to the installer ....................................................................................2 Control installation — EG-30 thru -75 water boilers without tankless heaters ........................ 4-5 Control installation — EG-30 thru -65 water boilers with tankless heaters .............................. 6-7 Control installation — EG-30 thru -75 and PEG-30 thru -65 steam boilers with probe... .....

Summary of the content on the page No. 4

                    Part Number 550-110-032/0607  EG-30thru75Series4andPEG-30thru65Series4

Summary of the content on the page No. 5

Standing Pilot Boilers—    ControlSupplement   Control installation For your safety, turn off electrical power supply and turn off external gas supply valve before attempting to work on the boiler. Failure to comply can cause severe personal injury, death or substantial property damage. EG-30 thru -65 water boilers without tankless heaters 1. Mount and wire controls per wiring diagram, page Figure 1 , and Figure1. a. Attach junction box inside left jac

Summary of the content on the page No. 6

                    Part Number 550-110-032/0607  EG-30thru75Series4andPEG-30thru65Series4

Summary of the content on the page No. 7

Standing Pilot Boilers — Control Supplement Control installation continued For your safety, turn off electrical power supply and turn off external gas supply valve before attempting to work on the boiler.F ailure to comply can cause severe personalinj ury, death or substantial property damage. EG-30 thru -65 water boilers with tankless heaters 1. Mount and wire controls per wiring diagram, page Figure 3 , and Figur e . a. Install combination limit c

Summary of the content on the page No. 8

                    Part Number 550-110-032/0607 8 EG-30thru75Series4andPEG-30thru65Series4

Summary of the content on the page No. 9

Standing Pilot Boilers — Control Supplement Control installation continued For your safety, turn off electrical power supply and turn off external gas supply valve before attempting to work on the boiler. Failuret o comply can cause severep ersonal injury, death or substantial property damage. EG-30 thru -65 and PEG-30 thru -65 steam boilers with probe-type low water cutoff 1. Mount and wire controls per wiring diagram, page Figure 4 8, and Figure.  a. Att

Summary of the content on the page No. 10

                    Part Number 550-110-032/0607 10 EG-30thru75Series4andPEG-30thru65Series4

Summary of the content on the page No. 11

Standing Pilot Boilers — Control Supplement Control installation continued For your safety, turn off electrical power supply and turn off external gas supply valve before attempting to work on the boiler. Failure to comply can causese verep ersonal injury, death or substantialp ropertydamag e. EG-30 thru -65 steam boilers with float-type low water cutoff 1. Mount and wire controls per wiring diagram, page Figure 6 10,and Figur e . a. Attach juncti

Summary of the content on the page No. 12

EG-30 thru 75 Series 4 andPEG-30    thru 65Series    4 Damper installation Once damper is installed, boiler will not operate without a damper installed. Only dampers listed in the Replacement parts table on page  are approved for use on EG and PEG Series  standing pilot boilers. Any other vent damper installed could cause severe personalinj ury or death. The following boiler models must have damper installed: • EG-30 thru EG-65, natural or prop

Summary of the content on the page No. 13

Standing Pilot Boilers — Control Supplement Damper installation continued Minimum clearances to combustibles Provide a minimum of  ” between the vent damper and any combustible material. (Provide a minimum of ” between jacket top and combustible ceiling.) See EG • PEG • EGH Boiler manual for complete clearance requirements. Installation Do not modify draft hood or damper, or make another connection between draft hood and damper or boiler

Summary of the content on the page No. 14

EG-30 thru 75 Series4    andPEG-30   thru    65 Series4   Checkout procedure 1. Seepag es1 -18f or “LightingI nstructions”. .  Raise roomthe rmostat tocal lf orheat. Damp er actuatorw ill slowly opendamp er. .  When damperis ful ly open, main gasv alvew illo penand main burnersw ill ignite. Damper must be fully open before main burners light. If damper does not fully open, flue products will escape into house, causing sev

Summary of the content on the page No. 15

Standing Pilot Boilers — Control Supplement Lighting instructions — Robertshaw 7200 Part Number 550-110-032/0607 1

Summary of the content on the page No. 16

EG-30 thru 75 Series 4and    PEG-30 thru 65 Series 4 Lighting instructions — Honeywell VR8200/VR8300 Natural gas boilers only Part Number 550-110-032/0607 1

Summary of the content on the page No. 17

Standing Pilot Boilers—    Control Supplement Lighting instructions — Honeywell VR8200/VR8300 Propane boilers only Part Number 550-110-032/0607 1

Summary of the content on the page No. 18

EG-30 thru 75 Series4   and    PEG-30 thru 65 Series4   Lighting instructions — Robertshaw 7000ERHC Part Number 550-110-032/0607 18

Summary of the content on the page No. 19

Standing Pilot Boilers — ControlSupplement   Troubleshooting Burner access panel must be in posi- In event of vent damper failure: tion during boiler operation to prevent momentary flame rollout on ignition of Effikal vent damper main flame. Severe personal injury or If troubleshooting chart recommends replacing actuator and actuator is substantialp roperty damage willr esult. not immediately available, damper blade can be fixed in an open posit

Summary of the content on the page No. 20

EG-30 thru 75 Series4   and    PEG-30 thru 65Series   4   Troubleshooting continued Figure 10 Pilot does not stay lit — Troubleshooting thermocouple or thermopile and high limit control circuit 1. Checkingthe rmocoupleo rthe rmopile opensy stem (Figure10): a. Use an electronic multimeter, with leads fitted with alligator clips. Set meter scalet o DC Millivolts. b. Unscrewthe rmocoupleo rthe rmopile fitting from gas valve. c. Attach one meter lead to the


Alternative user manuals
# User manual Category Download
1 Weil-McLain 382-200-305 User manual Boiler 1
2 Weil-McLain 550-141-830/1202 User manual Boiler 1
3 Weil-McLain 94 User manual Boiler 0
4 Weil-McLain 550-141-829/1201 User manual Boiler 1
5 Weil-McLain 68 User manual Boiler 1
6 Weil-McLain 88 User manual Boiler 2
7 Weil-McLain 68V User manual Boiler 0
8 Weil-McLain 550-141-826/1201 User manual Boiler 0
9 Weil-McLain B-66HE User manual Boiler 0
10 Weil-McLain 88 Series User manual Boiler 0
11 Weil-McLain BCP-3 User manual Boiler 4
12 Weil-McLain BCP-8S User manual Boiler 0
13 Weil-McLain A-66E User manual Boiler 0
14 Weil-McLain AFG User manual Boiler 1
15 Weil-McLain BMC User manual Boiler 0
16 Sony HDV 1080I HVR-M15N/M15P User manual Boiler 67
17 Sony HDV 1080I HVR-M25N/M25P User manual Boiler 50
18 A.O. Smith 200 User manual Boiler 2
19 A.O. Smith 201 User manual Boiler 7
20 A.O. Smith 750 & 1000 User manual Boiler 6