Bryant 558F.36.1 user manual

User manual for the device Bryant 558F.36.1

Device: Bryant 558F.36.1
Category: Air Conditioner
Manufacturer: Bryant
Size: 1.38 MB
Added : 11/14/2014
Number of pages: 20
Print the manual

Download

How to use this site?

Our goal is to provide you with a quick access to the content of the user manual for Bryant 558F.36.1. Using the online preview, you can quickly view the contents and go to the page where you will find the solution to your problem with Bryant 558F.36.1.

For your convenience

If looking through the Bryant 558F.36.1 user manual directly on this website is not convenient for you, there are two possible solutions:

  • Full Screen Viewing - to easily view the user manual (without downloading it to your computer), you can use full-screen viewing mode. To start viewing the user manual Bryant 558F.36.1 on full screen, use the button Fullscreen.
  • Downloading to your computer - You can also download the user manual Bryant 558F.36.1 to your computer and keep it in your files. However, if you do not want to take up too much of your disk space, you can always download it in the future from ManualsBase.
Bryant 558F.36.1 User manual - Online PDF
Advertisement
« Page 1 of 20 »
Advertisement
Print version

Many people prefer to read the documents not on the screen, but in the printed version. The option to print the manual has also been provided, and you can use it by clicking the link above - Print the manual. You do not have to print the entire manual Bryant 558F.36.1 but the selected pages only. paper.

Summaries

Below you will find previews of the content of the user manuals presented on the following pages to Bryant 558F.36.1. If you want to quickly view the content of pages found on the following pages of the manual, you can use them.

Abstracts of contents
Summary of the content on the page No. 1

wiring diagrams
558F
SINGLE PACKAGE ROOFTOP
036-150
ELECTRIC COOLING
1
3 to 12 / Tons
2
UNITS
Cancels: New WD 558F.36.1
11/15/00
DIAGRAM INDEX
UNIT LABEL DIAGRAM
Unit 558F Voltage-Phase-Hertz Type Label Diagram Figure No.
208/230-1-60 Schematic/Component Arrangement 50DK508524 1
208/230-3-60 Schematic/Component Arrangement 50DK508526 2
036,048
460-3-60 Schematic/Component Arrangement 50DK508529 3
575-3-60 Schematic/Component Arrangement 50DK508531 4
208/230-1-60 Schematic/Component Arrangement 5

Summary of the content on the page No. 2

NOTES FOR FIG. 1, 2, 5, 6, 9 1. If any of the original wire furnished must be replaced, it must be 4. Set heat anticipator at 1 amp. replaced with Type 90 C wire or its equivalent. 5. Use copper conductors only. 2. Three-phase motors are protected under primary single-phasing 6. Use copper, copper-clad aluminum or aluminum conductors. conditions. 7. For 208/230-3-60 v units: TRAN is wired for 230-v unit. If unit is to be 3. Thermostat: run with 208-v power supply, disconnect BLK wire from 230-v

Summary of the content on the page No. 3

Fig. 1 — Schematic/Component Arrangement; 558F036,048; 208/230-1-60 —3—

Summary of the content on the page No. 4

Fig. 2 — Schematic/Component Arrangement; 558F036,048; 208/230-3-60 —4—

Summary of the content on the page No. 5

Fig. 3 — Schematic/Component Arrangement; 558F036,048; 460-3-60 —5—

Summary of the content on the page No. 6

Fig. 4 — Schematic/Component Arrangement; 558F036,048; 575-3-60 —6—

Summary of the content on the page No. 7

Fig. 5 — Schematic/Component Arrangement; 558F060; 208/230-1-60 —7—

Summary of the content on the page No. 8

Fig. 6 — Schematic/Component Arrangement; 558F060; 208/230-3-60 —8—

Summary of the content on the page No. 9

Fig. 7 — Schematic/Component Arrangement; 558F060; 460-3-60 —9—

Summary of the content on the page No. 10

Fig. 8 — Schematic/Component Arrangement; 558F060; 575-3-60 —10—

Summary of the content on the page No. 11

Fig. 9 — Schematic/Component Arrangement; 558F072; 208/230-3-60 and 460-3-60 —11—

Summary of the content on the page No. 12

Fig. 10 — Schematic/Component Arrangement; 558F072; 575-3-60 —12—

Summary of the content on the page No. 13

—13— Fig. 11 — Schematic/Component Arrangement; 558F090-150; 208/230-3-60 and 460-3-60

Summary of the content on the page No. 14

—14— Fig. 12 — Schematic/Component Arrangement; 558F090-150; 575-3-60

Summary of the content on the page No. 15

558F036-072 LEGEND C — Contactor 558F090-150 Fig. 13 — Motormaster® I Wiring Details LEGEND C— Contactor OFC — Outdoor-Fan Contactor TRAN — Transformer NOTE: Motormaster II transformer is wired for 460-v supply; it must be rewired for 208/230-v application. Be sure to insulate unused tap. Refer to color code. Fig. 14 — Motormaster II Wiring Schematic; 558F036-072 —15—

Summary of the content on the page No. 16

LEGEND C— Contactor OFC — Outdoor-Fan Contactor TRAN — Transformer *The Motormaster II head pressure controller is equipped with an alternate operating mode. When this mode is selected, the controller shifts the fan cycle sequence to effectively raise the average condensing temperature approximately 20 F higher than the standard operating mode. In this alternate mode, the outdoor fan begins cycling at higher outdoor ambient temperatures. This mode should only be used if the evaporator coil shows

Summary of the content on the page No. 17

BRN TIME GUARD I I DEVICE BRN 2 T1 T2 1 3 T3 CLO C COMPRESSOR OR SAFETIES CR 1 HIGH EFFICIENCY 3 TO 12 / TON ROOFTOP UNITS 2 BRN TIME GUARD I I DEVICE T1 T3 T2 C OR CR 1 STANDARD EFFICIENCY 3 TO 12 / TON ROOFTOP UNITS 2 LEGEND C — Contactor CLO — Compressor Lockout CR — Control Relay Fig. 16 — Time Guard® II Device; 558F036-150 24 VAC SUPPLY FROM 24 VAC SUPPLY FROM ECONOMIZER CONTROL ECONOMIZER CONTROL } SECTION (RED TO TR, SECTION (RED TO TR, TR1 TR BRN TO TR1) BRN TO TR1) B B TR TR1 A C C

Summary of the content on the page No. 18

LEGEND OAT — Outdoor-Air Thermostat Fig. 19 — EconoMi$er Wiring ECONOMI$ER BROWN TEMP CONTROLLER VIOLET TEMP OUTDOOR AIR OAT COM SENSOR WHITE COM OUT RED PWR OAH -15 V BROWN RAT TEMP VIOLET RETURN TEMP COM AIR WHITE COM SENSOR RAH OUT RED +15 V PWR CO SENSOR 2 (+) V+ 24 CO 2 CO2 COM COM VAC DAT COM SUPPLY AIR TEMPERATURE SENSOR REM POT PINK COM TEMP LED VIOLET TEMP COM Fig. 20 — EconoMi$er Sensor Wiring; 558F036-150 —18—

Summary of the content on the page No. 19

TO FUSED DISCONNECT RED GRAY RED YEL BLU GRAY H1 H2 H1 H3 H2 H4 X4 X2 X3 X1 X4 X2 X3 X1 FIELD SUPPLIED WIRING SECONDARY SECONDARY 230VAC 230VAC BLACK BLACK COMPRESSOR 1 OR CONTACTOR LT. BLUE 3 B 11 21 6 9 230VAC BROWN BLACK 13 23 FAN 1 R1 3-PIN 2 5 8 24 VAC C1 CONNECTOR GREEN/ PLUG YELLOW 1 4 7 A 4-PIN CONNECTOR 2 x 4 IN. BLUE ORANGE 1 PLUG HANDY BOX YELLOW L1 2 BLACK L1 1 1 L2 BLUE L2 BROWN 22 3 GREEN GND GND 33 BLACK BLACK 44 BLUE 230 VAC LT. BLUE GREEN 1 PHASE 3 6 9 B BLACK R2 BROWN F

Summary of the content on the page No. 20

Copyright 2000 Bryant Heating & Cooling Systems CATALOG NO. 5355-810


Alternative user manuals
# User manual Category Download
1 Bryant 113A User manual Air Conditioner 365
2 Bryant 24B User manual Air Conditioner 61
3 Bryant 187B User manual Air Conditioner 39
4 Bryant 342S User manual Air Conditioner 17
5 Bryant 39479D8 User manual Air Conditioner 31
6 Bryant 342 User manual Air Conditioner 15
7 Bryant 165A User manual Air Conditioner 22
8 Bryant 450D User manual Air Conditioner 21
9 Bryant 451P User manual Air Conditioner 7
10 Bryant 451 User manual Air Conditioner 7
11 Bryant 36-453 User manual Air Conditioner 10
12 Bryant 452W User manual Air Conditioner 6
13 Bryant 452 User manual Air Conditioner 3
14 Bryant 454 User manual Air Conditioner 112
15 Bryant 463AAC008BA User manual Air Conditioner 17
16 Sony SU-PW2 User manual Air Conditioner 12
17 Sony CV-P12PX User manual Air Conditioner 3
18 Sony MULTI CHANNEL AV RECEIVER STR-DG710 User manual Air Conditioner 31
19 Sony VGN-BX500 User manual Air Conditioner 1
20 Philips 190S5 User manual Air Conditioner 21