Blue Rhino ENDLESS SUMMER 233010 user manual

User manual for the device Blue Rhino ENDLESS SUMMER 233010

Device: Blue Rhino ENDLESS SUMMER 233010
Category: Oven
Manufacturer: Blue Rhino
Size: 6.15 MB
Added : 8/1/2014
Number of pages: 27
Print the manual

Download

How to use this site?

Our goal is to provide you with a quick access to the content of the user manual for Blue Rhino ENDLESS SUMMER 233010. Using the online preview, you can quickly view the contents and go to the page where you will find the solution to your problem with Blue Rhino ENDLESS SUMMER 233010.

For your convenience

If looking through the Blue Rhino ENDLESS SUMMER 233010 user manual directly on this website is not convenient for you, there are two possible solutions:

  • Full Screen Viewing - to easily view the user manual (without downloading it to your computer), you can use full-screen viewing mode. To start viewing the user manual Blue Rhino ENDLESS SUMMER 233010 on full screen, use the button Fullscreen.
  • Downloading to your computer - You can also download the user manual Blue Rhino ENDLESS SUMMER 233010 to your computer and keep it in your files. However, if you do not want to take up too much of your disk space, you can always download it in the future from ManualsBase.
Blue Rhino ENDLESS SUMMER 233010 User manual - Online PDF
Advertisement
« Page 1 of 27 »
Advertisement
Print version

Many people prefer to read the documents not on the screen, but in the printed version. The option to print the manual has also been provided, and you can use it by clicking the link above - Print the manual. You do not have to print the entire manual Blue Rhino ENDLESS SUMMER 233010 but the selected pages only. paper.

Summaries

Below you will find previews of the content of the user manuals presented on the following pages to Blue Rhino ENDLESS SUMMER 233010. If you want to quickly view the content of pages found on the following pages of the manual, you can use them.

Abstracts of contents
Summary of the content on the page No. 1

®
Cleaning Instructions,
Pilot Replacement and
Valve Change
Model No.:
233010
Natural Gas

Summary of the content on the page No. 2

® ® For assistance call 1.800.762.1142. For assistance call 1.800.762.1142. Tools required: • 8mm open-end wrench • 9mm open-end wrench • 10mm open-end wrench • 12mm open-end wrench • 13mm open-end wrench • Phillips screw driver • 5/8” open end wrench • 3/4” open end wrench • Needle nose pliers • Soap and water solution (to check for leaks) DANGERS and Cautions 1. Installation and repair should be done by a qualified service person. 2. Use only Blue Rhino Global Sourcing, LLC. factory authorize

Summary of the content on the page No. 3

® ® For assistance call 1.800.762.1142. For assistance call 1.800.762.1142. Steps 1-4 1. T urn gas supply off and disconnect from gas supply. Important: make sure your gas supply is off. 2. Remove dome. 3. Remove engine from post. Cleaning burner, pilot replacement and valve change. Model No. 233010 Natural Gas 501310 1 Cleaning burner, pilot replacement and valve change. Model No. 233010 Natural Gas 501310 2

Summary of the content on the page No. 4

® ® For assistance call 1.800.762.1142. For assistance call 1.800.762.1142. Step 5 Remove the three bolts which secure the emitter to the emitter bottom using a 9mm wrench. Cleaning burner, pilot replacement and valve change. Model No. 233010 Natural Gas 501310 3 Cleaning burner, pilot replacement and valve change. Model No. 233010 Natural Gas 501310 4

Summary of the content on the page No. 5

® ® For assistance call 1.800.762.1142. For assistance call 1.800.762.1142. Step 6 1. Clean the carbon build-up off the inside of the emitter bottom with a non-abrasive scouring pad or bottle brush. Clean the outside of the emitter bottom with the scouring pad. 2. Use the air compressor to blow away any excess soot. DANGER : Never use any flammable solutions or material to clean heater or heater parts. Use only a mild soap and water solution. Do not to soak the valve. Cleaning burner, p

Summary of the content on the page No. 6

® ® For assistance call 1.800.762.1142. For assistance call 1.800.762.1142. Step 7 Disconnect the pilot supply tube using #10 open-ended wrench. Cleaning burner, pilot replacement and valve change. Model No. 233010 Natural Gas 501310 5 Cleaning burner, pilot replacement and valve change. Model No. 233010 Natural Gas 501310 6

Summary of the content on the page No. 7

® ® For assistance call 1.800.762.1142. For assistance call 1.800.762.1142. Step 8 Disconnect the burner supply tube from the control valve using 5/8” open-ended wrench. Cleaning burner, pilot replacement and valve change. Model No. 233010 Natural Gas 501310 5 Cleaning burner, pilot replacement and valve change. Model No. 233010 Natural Gas 501310 6

Summary of the content on the page No. 8

® ® For assistance call 1.800.762.1142. For assistance call 1.800.762.1142. Step 9 1. Disconnect the burner from the emitter bottom by removing the 2 phillips screws on the bottom of the emitter bottom. 2. Carefully remove the burner. Cleaning burner, pilot replacement and valve change. Model No. 233010 Natural Gas 501310 7 Cleaning burner, pilot replacement and valve change. Model No. 233010 Natural Gas 501310 8

Summary of the content on the page No. 9

® ® For assistance call 1.800.762.1142. For assistance call 1.800.762.1142. Step 10 Disconnect the thermal couple wire from the control valve: 1. Remove the screw that holds the access panel to the housing. 2. Remove the nut from the back of the control valve using 8 mm open-ended wrench. Note: Be very careful not to damage any wires. Cleaning burner, pilot replacement and valve change. Model No. 233010 Natural Gas 501310 7 Cleaning burner, pilot replacement and valve change. Model No. 2

Summary of the content on the page No. 10

® ® For assistance call 1.800.762.1142. For assistance call 1.800.762.1142. Step 11 Remove the heat and pilot shield from the emitter bottom. 1. Remove the 4 screws in emitter bottom. Note: 2 screws are near pilot opening, and 2 screws are on the back side of the emitter bottom. 2. Lift the heat shield assembly out. Note: Be very careful not to damage any wires. Cleaning burner, pilot replacement and valve change. Model No. 233010 Natural Gas 501310 9 Cleaning burner, pilot replacement a

Summary of the content on the page No. 11

® ® For assistance call 1.800.762.1142. For assistance call 1.800.762.1142. Step 12 1. Remove the pilot assembly by removing the 2 screws that hold the pilot assembly in place Note: you may need to use a pair of needle nose pliers to hold the nuts in place. 2. If replacing the pilot: A. Remove the ignitor wire, by carefully bending the fork on the retaining bracket up using need nose pliers B. Pull down on the ceramic tube C. Disconnect the igniter wire from the pilot. D. Replace the old

Summary of the content on the page No. 12

® ® For assistance call 1.800.762.1142. For assistance call 1.800.762.1142. Step 13 1. Remove the orifice by placing the 12 mm open-ended on the pilot orifice and the 10 mm open-ended on the hex tube just below the pilot hood. 2. Use a pipe cleaner to clean both the inside and outside of the pilot orifice. 3. With a brush, lightly clean the top of the pilot orifice. Use care not to enlarge the orifice hole. Cleaning burner, pilot replacement and valve change. Model No. 233010 Natural Ga

Summary of the content on the page No. 13

® ® For assistance call 1.800.762.1142. For assistance call 1.800.762.1142. 1. Use a heavy-duty pipe cleaner to clean the bottom of the black hex tube on the pilot assembly. Make sure to extend the pipe cleaner past the silver hood. 2. Clean the port at the side of the pilot hood with a heavy-duty pipe cleaner. 3. Blow out any excess soot or debris with an air hose or a can of compressed air. Cleaning burner, pilot replacement and valve change. Model No. 233010 Natural Gas 501310 11 Clea

Summary of the content on the page No. 14

® ® For assistance call 1.800.762.1142. For assistance call 1.800.762.1142. Step 14 Insert bottle brush into venturi tube and give a couple of twists. This will clear any debris or spider webs from the venturi tube. Cleaning burner, pilot replacement and valve change. Model No. 233010 Natural Gas 501310 13 Cleaning burner, pilot replacement and valve change. Model No. 233010 Natural Gas 501310 14

Summary of the content on the page No. 15

® ® For assistance call 1.800.762.1142. For assistance call 1.800.762.1142. Step 15 1. Insert a heavy-duty pipe cleaner into each burner port to clean them. Use a non-abrasive scouring pad to clean the outside of the burner. 2. Using an air hose or can of compressed air to blow any excess soot from the burner ports and the venturi tube. 3. Use a brush or compressed air to clean the burner orifice. Note: Be careful not to enlarge any holes. Cleaning burner, pilot replacement and valve cha

Summary of the content on the page No. 16

® ® For assistance call 1.800.762.1142. For assistance call 1.800.762.1142. Step 16 If this is all you need to do then follow instructions in reverse to reassemble heater. If not, please continue. Cleaning burner, pilot replacement and valve change. Model No. 233010 Natural Gas 501310 15 Cleaning burner, pilot replacement and valve change. Model No. 233010 Natural Gas 501310 16

Summary of the content on the page No. 17

® ® For assistance call 1.800.762.1142. For assistance call 1.800.762.1142. Step 17 Replacing the control valve: 1. Remove the control valve by removing the 3/4” brass nut on the front side of the valve housing. 2. Push the control valve back and pull it out from the front of the valve housing. Note: Be careful not to damage the pilot supply tube. 3. Remove the pilot supply tube from the old control valve using 13 mm open-ended wrench or 1/2” open-ended wrench. Cleaning burner, pilot replace

Summary of the content on the page No. 18

® ® For assistance call 1.800.762.1142. For assistance call 1.800.762.1142. 4. Attach the pilot supply tube to the new control valve 5. Install the new control valve. Note: Make sure the valve is secure. 6. Reattach the 3/4” brass nut. Cleaning burner, pilot replacement and valve change. Model No. 233010 Natural Gas 501310 17 Cleaning burner, pilot replacement and valve change. Model No. 233010 Natural Gas 501310 18

Summary of the content on the page No. 19

® ® For assistance call 1.800.762.1142. For assistance call 1.800.762.1142. Step 18 1. Place pilot assembly with heat shield into the emitter bottom 2. Attach the pilot supply tube to the pilot. 3. Tighten the screws that hold the guard in place. Cleaning burner, pilot replacement and valve change. Model No. 233010 Natural Gas 501310 17 Cleaning burner, pilot replacement and valve change. Model No. 233010 Natural Gas 501310 18

Summary of the content on the page No. 20

® ® For assistance call 1.800.762.1142. For assistance call 1.800.762.1142. Step 19 1. Reinstall the thermal couple by attaching the nut on the back of the control valve, using the 8 mm open-end wrench. Note: Finger tighten the nut, plus a 1⁄4 turn 2. Reinstall the access panel. Cleaning burner, pilot replacement and valve change. Model No. 233010 Natural Gas 501310 19 Cleaning burner, pilot replacement and valve change. Model No. 233010 Natural Gas 501310 20


Alternative user manuals
# User manual Category Download
1 Blue Rhino ENDLESS SUMMER 233010 User manual Patio Heater 1
2 Edelbrock 17008 User manual Oven 0
3 3Com User manual Oven 1
4 ADIC 5.4 User manual Oven 1
5 AEG BC3000001 User manual Oven 527
6 AEG B3101-5-M User manual Oven 328
7 AEG BP7614000 User manual Oven 73
8 AEG BS7304001M User manual Oven 103
9 AEG BP5013001M User manual Oven 143
10 AEG BP5003001 User manual Oven 96
11 AEG BP8314001 User manual Oven 33
12 AEG B 60 D User manual Oven 23
13 AEG COMPETENCE B4101-4 User manual Oven 1204
14 AEG COMPETENCE 520B User manual Oven 629
15 AEG COMPETENCE E1100-4 User manual Oven 229