Raypak 992BE user manual

User manual for the device Raypak 992BE

Device: Raypak 992BE
Category: Boiler
Manufacturer: Raypak
Size: 0.12 MB
Added : 9/18/2013
Number of pages: 5
Print the manual

Download

How to use this site?

Our goal is to provide you with a quick access to the content of the user manual for Raypak 992BE. Using the online preview, you can quickly view the contents and go to the page where you will find the solution to your problem with Raypak 992BE.

For your convenience

If looking through the Raypak 992BE user manual directly on this website is not convenient for you, there are two possible solutions:

  • Full Screen Viewing - to easily view the user manual (without downloading it to your computer), you can use full-screen viewing mode. To start viewing the user manual Raypak 992BE on full screen, use the button Fullscreen.
  • Downloading to your computer - You can also download the user manual Raypak 992BE to your computer and keep it in your files. However, if you do not want to take up too much of your disk space, you can always download it in the future from ManualsBase.
Raypak 992BE User manual - Online PDF
Advertisement
« Page 1 of 5 »
Advertisement
Print version

Many people prefer to read the documents not on the screen, but in the printed version. The option to print the manual has also been provided, and you can use it by clicking the link above - Print the manual. You do not have to print the entire manual Raypak 992BE but the selected pages only. paper.

Summaries

Below you will find previews of the content of the user manuals presented on the following pages to Raypak 992BE. If you want to quickly view the content of pages found on the following pages of the manual, you can use them.

Abstracts of contents
Summary of the content on the page No. 1

Catalog No.: 2000.952D
®
HI DELTA , TYPE H - MODELS 992BE-2342BE

Effective: 9-1-09

SUGGESTED SPECIFICATIONS
Replaces: 5-1-08


DIVISION 23 52 33.13

FINNED WATER-TUBE BOILERS
PART 1 - GENERAL
1.1 SUMMARY
A. Section includes gas-fired, copper finned-tube hydronic heating boilers
B. Related Sections
Specifier Note: Use as needed
1. Building Services Piping – Division 23 21 00
2. Breeching, Chimneys, and Stacks (Venting) – Division 23 51 00
3. HVAC Instrumentation and Controls –

Summary of the content on the page No. 2

Fax: (800) 872-9725; Web site: www.raypak.com ® 2. Product: Hi Delta copper finned-tube hydronic boiler(s) 2.2 BOILERS A. General 1. The boiler(s) shall be fired with gas at a rated input of BTU/hr. 2. The boiler(s) shall be CSA tested and certified with a minimum thermal efficiency of 87 percent at full fire. 3. The boiler(s) shall be ASME inspected and stamped and National Board registered for 160 PSIG working pressure, complete with a Manufacturer's Data Report. 4. The bo

Summary of the content on the page No. 3

d. Temperature and pressure gauge 2. The boiler(s) shall be equipped with an energy-saving pump control relay (Economaster II), mounted and wired, which automatically shuts off the boiler pump at a set period after boiler shut-down (adjustable for five or ten minutes) to avoid standby losses associated with constant pump operation. G. Firing Mode 1. For models 992BE, provide three-stage firing control of the gas input to the boiler. 2. For models 1262BE-2342BE, provide four-stage firing c

Summary of the content on the page No. 4

powder coat which is suitable for outdoor installation, applied prior to assembly for complete coverage, and shall incorporate louvers in the outer panels to divert air past heated surfaces. 2. The boiler(s), if located on a combustible floor, shall not require a separate combustible floor base. 3. The boiler(s) shall have the option of venting the flue products either through the top or the back of the unit. 4. Combustion air intake shall be on the left side of the cabinet, right side opt

Summary of the content on the page No. 5

c. Inlet temperature error d. Sensor out of range 6. The controller shall have alarm contacts. Q. Low Gas Supply Pressure Manifold 1. The boiler(s) shall be CSA certified for full-input operation down to 4.0” WC dynamic inlet gas supply pressure. R. TruSeal™ Direct Vent 1. The boiler(s) shall meet safety standards for direct vent equipment as noted by the 2006 Uniform Mechanical Code, section 1107.6, ASHRAE 15-1994, section 8.13.6, and ANSI Z21.13/CSA 4.9. 2.3 SOURCE QUALITY CONTROL A


Alternative user manuals
# User manual Category Download
1 Raypak 0090B 0135B User manual Boiler 32
2 Raypak 1001 User manual Boiler 17
3 Raypak 1000 .19C User manual Boiler 1
4 Raypak 181-401 User manual Boiler 5
5 Raypak 1501 User manual Boiler 9
6 Raypak 0180B Type H User manual Boiler 3
7 Raypak 133 User manual Boiler 0
8 Raypak 180B User manual Boiler 1
9 Raypak 2100-4001 User manual Boiler 7
10 Raypak 240692 User manual Boiler 0
11 Raypak 241275 User manual Boiler 0
12 Raypak 182-400 User manual Boiler 6
13 Raypak 2342BE User manual Boiler 0
14 Raypak 1000 User manual Boiler 0
15 Raypak 302BD-902BD User manual Boiler 0
16 Sony HDV 1080I HVR-M15N/M15P User manual Boiler 67
17 Sony HDV 1080I HVR-M25N/M25P User manual Boiler 50
18 A.O. Smith 200 User manual Boiler 2
19 A.O. Smith 201 User manual Boiler 7
20 A.O. Smith 750 & 1000 User manual Boiler 6