Summary of the content on the page No. 1
Combitherm ®
Combination
Oven / Steamer
ES GAS
COMBITOUCH™
SERIES
6•10ESG
10•10ESG
7•14ESG
10•20ESG
12•18ESG
20•20ESG
• INSTALLATION
W164 N9221 Water Street • P.O. Box 450 • Menomonee Falls, Wisconsin 53052-0450 USA
PHONE: 262.251.3800 • 800.558.8744 USA/CANADA FAX: 262.251.7067 • 800.329.8744 U.S.A. ONLY
WWW.ALTO-SHAAM.COM
MN-29246 • 10/10
PRINTED IN U.S.A.
Summary of the content on the page No. 2
Delivery .......................................................................... 1 Electrical Connection ............................................... 13 Unpacking ..................................................................... 1 Mobile Equipment Restraint ..................................... 14 Safety Procedures and Precautions .............................. 2 Ventilation Requirements ......................................... 15 Gas Supply & Installation ............................
Summary of the content on the page No. 3
® DELIVERY UNPACKING 1. Carefully remove the This Alto-Shaam appliance has been appliance from the thoroughly tested and inspected to ensure only carton or crate. the highest quality unit is provided. Upon receipt, check for any possible shipping damage NOTE: Do not discard the and report it at once to the delivering carrier. carton and other See Transportation Damage and Claims section packaging material located in this manual. until you have This appliance, complete with una
Summary of the content on the page No. 4
SAFETY PROCEDURES AND PRECAUTIONS Knowledge of proper procedures is essential to the 1. This appliance is intended to cook, hold safe operation of electrically and/or gas energized or process foods for the purpose of human equipment. In accordance with generally accepted consumption. No other use for this appliance is product safety labeling guidelines for potential authorized or recommended. hazards, the following signal words and symbols 2. This appliance is intended for use in comme
Summary of the content on the page No. 5
INSTALLATION SITE INSTALLATION DANGER DANGER IMPROPER INSTALLATION, AVERTISSEMENT : UNE INSTALLATION, ALTERATION, ADJUSTMENT, UN AJUSTEMENT, UNE ALTÉRATION, UN SERVICE OU UN ENTRETIEN NON SERVICE, OR MAINTENANCE COULD CONFORME AUX NORMES PEUT CAUSER RESULT IN SEVERE INJURY, DEATH, DES DOMMAGES À LA PROPRIÉTÉ, DES OR CAUSE PROPERTY DAMAGE. BLESSURES OU LA MORT. READ THE INSTALLATION, OPERATING AND MAINTENANCE LIRE ATTENTIVEMENT LES DIRECTIVES INSTRUCTIONS THOROUGHLY D’OPÉRATION ET D’ENTRET
Summary of the content on the page No. 6
INSTALLATION SITE INSTALLATION POSITIONING ON SITE Lift the oven from the pallet with a fork lift or pallet lift truck positioned at the front of the oven. For damage protection, the use of two wooden boards, placed between the bottom of the oven and the lifting forks, is strongly recommended. To avoid damage, position the lift forks to the left of the condenser and right of the right leg as indicated in the diagram above. NOTE: To avoid equipment damage, observe Stand the oven in a leve
Summary of the content on the page No. 7
INSTALLATION SITE INSTALLATION POSITIONING REQUIREMENTS q In order to ensure proper ventilation, a minimum distance of at least 6-inches (152mm) must be kept from the control panels side (left) of the oven and any adjoining surfaces. NOTE: Additional clearance is needed for service access. A minimum distance of 18-inches is strongly recommended. If adequate service clearance is not RETRACTABLE DOOR provided, it will be necessary to disconnect the gas, OPTION: water, and drain to move
Summary of the content on the page No. 8
INSTALLATION COMMON SPECIFICATIONS q CombiGuard™ BWS Blended Water System FI-28727 (INCLUDES 50 GALLON TANK, 1 MEMBRANE & 3 FILTERS) q CombiGuard™ BWS Replacement Filter Cartridge AMS-QT FI-29316 q CombiGuard™ BWS Replacement Filter Cartridge SCLX2-Q FI-29317 q CombiGuard™ BWS Replacement Prefilter Six (6) Chicken Roasting Rack Filter Cartridge CTO-Q FI-29318 (PAN NOT INCLUDED) SH-23000 CombiGuard™ Triple-Guard Water Filtration System (INCLUDES 1 CARTRIDGE) q 6•10, 10•10, 7•14 (Combi
Summary of the content on the page No. 9
6•10ESG 5-11/16" (144mm) 4-1/2" (114mm) 15-3/16" 42-1/16" (1068mm) 37" (939mm) 2-15/16" (385mm) 40-1/8" (74mm) Water Drain 34-5/16" (1018mm) (Back Side) (871mm) Steam A B Vent C (Top) Water Drain (Bottom) D A = UNTREATED WATER 25" 7-1/2" 21-11/16" B = TREATED WATER 5-3/16" (550mm) 2" (50mm) (635mm) (191mm) C = ELECTRICAL (131mm) D = GAS DIMENSIONS: H x W x D EXTERIOR: 47-5/16" (1201mm) 35-1/4” x 42-1/16” x 37” (895mm x 1068mm x 939mm) EXTERIOR WITH RECESSED DOOR: 35-1/4” x 46-1/16” x 37” (895m
Summary of the content on the page No. 10
10•10ESG 5-11/16" (144mm) 42-1/16" (1068mm) 37" (939mm) 40-1/8" 34-5/16" 4-1/2" (114mm) 15-3/16" (1018mm) (871mm) 2-15/16" (385mm) (74mm) Water Drain (Back Side) Steam A B Vent C (Top) Water Drain (Bottom) D A = UNTREATED WATER 25" 7-1/2" 5-3/16" 21-11/16" B = TREATED WATER 2" (50mm) (635mm) (191mm) (131mm) (550mm) C = ELECTRICAL D = GAS DIMENSIONS: H x W x D 47-5/16" (1201mm) EXTERIOR: 44-15/16” x 42-1/16” x 37” (1141mm x 1068mm x 939mm) EXTERIOR WITH RECESSED DOOR: 44-15/16” x 46-1/16”
Summary of the content on the page No. 11
7•14ESG 44-7/16" (1128mm) 27-7/8" 41-5/8" (1057mm) (708mm) 49-13/16" (1265mm) 12-13/16" 22-11/16" [D] 4-3/8" (110mm) Water Drain 47-7/8" (1215mm) (325mm) [C] 3-9/16" (575mm) (Side Back) (89mm) C Steam Vent (Top) A Water Drain B (Bottom) D 31-3/4" 7-9/16" (650mm) (192mm) (805mm) 2" (50mm) 8-1/2" (216mm) 33-1/8" 7-3/16" [D] 4-5/8" (116mm) (840mm) (181mm) A = UNTREATED WATER B = TREATED WATER DIMENSIONS: H x W x D C = ELECTRICAL D = GAS EXTERIOR: 55-1/16" (1398mm) 42” x 49-13/16” x 44-7/16” (1066
Summary of the content on the page No. 12
10•20ESG 45-3/16" (1148mm) [D] 4-9/16" (116mm) 19-15/16" [A,B] 4-3/8" (110mm) 42-7/16" (506mm) 49-13/16" (1265mm) (1077mm) [C] 3-9/16" Water Drain (89mm) 22-11/16" 12-13/16" (Side Back) 47-7/8" (1215mm) (325mm) (575mm) C Steam Vent (Top) A B D Water Drain (Bottom) [D] 4-5/8" (116mm) 30-5/8" 31-3/4" (778mm) 2" (50mm) (805mm) A = UNTREATED WATER 32-13/16" 2-3/16" 2" (833mm) B = TREATED WATER 44" (1118mm) (56mm) (50mm) C = ELECTRICAL 55-7/16" D = GAS (1407mm) DIMENSIONS: H x W x D EXTERIOR: 54-
Summary of the content on the page No. 13
12•18ESG 45-3/16" (1148mm) [D] 4-9/16" (116mm) 19-15/16" 42-7/16" [A,B] 4-3/8" (110mm) (506mm) 49-13/16" (1265mm) (1077mm) [C] 3-9/16" Water Drain (89mm) 12-13/16" 22-11/16" 47-7/8" (1215mm) (Side Back) (325mm) (575mm) C Steam Vent (Top) A B D Water Drain (Bottom) [D] 4-5/8" (116mm) 31-3/4" 25-5/8" 2" (50mm) (805mm) (650mm) A = UNTREATED WATER 33-1/8" 7-5/16" 8-1/2" (216mm) B = TREATED WATER (840mm) (185mm) C = ELECTRICAL 55-7/16" D = GAS (1407mm) DIMENSIONS: H x W x D EXTERIOR: 51-3/8” x 49
Summary of the content on the page No. 14
20•20ESG [D] 4-9/16" (116mm) 45-3/16" (1148mm) 19-15/16" 49-13/16" (1264mm) [A,B] 4-3/8" (110mm) (506mm) 42-9/16" (1080mm) [C] 3-9/16" 47-13/16" (1214mm) Water Drain (89mm) (Side Back) C Steam A Vents B (Top) D [D] 4-5/8" (116mm) Water Drain (Bottom) 2" (50mm) A = UNTREATED WATER B = TREATED WATER 30-5/8" C = ELECTRICAL (778mm) D = GAS 55-7/16" 44" (1118mm) 2" 2-3/16" 32-13/16" (1407mm) (49mm) (56mm) (833mm) DIMENSIONS: H x W x D EXTERIOR: 76-5/8” x 49-13/16” x 45-3/16” (1946mm x 1264mm x
Summary of the content on the page No. 15
INSTALLATION ELECTRICAL MODEL VOLTAGE PHASE CIRCUIT AWG DANGER 6•10esG AND 110-120 1 20 A 2 WIRE 6•10esG/SK ELECTRICAL GROUNDING 7•14esG AND 110-120 1 20 A 2 WIRE INSTRUCTIONS: 7•14esG/SK This appliance is equipped with a 10•10esG AND 110-120 1 20 A 2 WIRE three-pronged (grounding) plug for 10•10esG/SK your protection against shock hazard 10•20esG AND 110-120 1 20 A 2 WIRE and should be plugged directly into 10•20esG/SK a properly grounded three-prong 12•18esG AND 110-120 1 20 A 2 WI
Summary of the content on the page No. 16
INSTALLATION MOBILE EQUIPMENT RESTRAINT The gas Combitherm must use a connector that 1. Install a manual gas shut-off valve along with an complies with The Standard for Connectors for approved disconnect device. Movable Gas Appliances, ANSI Z21.69 CSA 6.16 and 2. Install an A.G.A. certified, heavy-duty connector addenda Z21.69a-1989. A quick disconnect devise that complies with ANSI Z 21.69 or must be installed to comply with The Standard for CAN 1-6.10m88 along with a quick-disconnec
Summary of the content on the page No. 17
INSTALLATION VENTILATION REQUIREMENTS An adequate ventilation system is required for DANGER commercial cooking equipment. Information may be Installation, air adjustment and/or obtained by writing to the National Fire Protection service work must be in accordance Association, Batterymarch Park, Quincy, MA 02269. with all local codes and must be When writing refer to NFPA No. 96. performed by a certifi ed service technician qualifi ed to work on gas appliances. 4. This oven cannot be dir
Summary of the content on the page No. 18
INSTALLATION GAS SUPPLY & INSTALLATION The Alto-Shaam gas Combitherm has been set to operate with either natural gas or propane as DANGER indicated on the identification name plate. Make certain the gas supply matches the nameplate CONNECTING TO THE WRONG GAS information. Should conversion to the opposite SUPPLY COULD RESULT IN FIRE OR fuel be desired, conversion parts must be ordered AN EXPLOSION CAUSING SEVERE from the factory. Conversion must be completed by INJURY AND PROPERTY DAMAGE
Summary of the content on the page No. 19
INSTALLATION GAS SUPPLY & INSTALLATION DANGER DANGER Installation, air adjustment and/or DO NOT store or use gasoline or other service work must be in accordance fl ammable vapors or liquids in the with all local codes and must be vicinity of this or any other appliance. performed by a certifi ed service technician qualifi ed to work on gas appliances. DANGER NE PAS entreposer ni utiliser Remove any tape d'essence ou d'autres vapeurs ou or compound liquides infl ammables à proximité d
Summary of the content on the page No. 20
INSTALLATION GAS SUPPLY & INSTALLATION The other end of the cable should be permanently The minimum size requirement for gas piping or a attached to the rear frame of the oven. The cable flexible connector is 3/4 - inch (19mm). For long runs should be of sufficient length so that no strain is ever of gas piping, the pipe diameter must conform to the placed on the flexible gas connector in the event of tables in the National Fuel Gas Code, ANSI/NFPA accidental movement of the oven without