PVI Industries PV500-40 user manual

User manual for the device PVI Industries PV500-40

Device: PVI Industries PV500-40
Category: Boiler
Manufacturer: PVI Industries
Size: 0.13 MB
Added : 9/18/2013
Number of pages: 6
Print the manual

Download

How to use this site?

Our goal is to provide you with a quick access to the content of the user manual for PVI Industries PV500-40. Using the online preview, you can quickly view the contents and go to the page where you will find the solution to your problem with PVI Industries PV500-40.

For your convenience

If looking through the PVI Industries PV500-40 user manual directly on this website is not convenient for you, there are two possible solutions:

  • Full Screen Viewing - to easily view the user manual (without downloading it to your computer), you can use full-screen viewing mode. To start viewing the user manual PVI Industries PV500-40 on full screen, use the button Fullscreen.
  • Downloading to your computer - You can also download the user manual PVI Industries PV500-40 to your computer and keep it in your files. However, if you do not want to take up too much of your disk space, you can always download it in the future from ManualsBase.
PVI Industries PV500-40 User manual - Online PDF
Advertisement
« Page 1 of 6 »
Advertisement
Print version

Many people prefer to read the documents not on the screen, but in the printed version. The option to print the manual has also been provided, and you can use it by clicking the link above - Print the manual. You do not have to print the entire manual PVI Industries PV500-40 but the selected pages only. paper.

Summaries

Below you will find previews of the content of the user manuals presented on the following pages to PVI Industries PV500-40. If you want to quickly view the content of pages found on the following pages of the manual, you can use them.

Abstracts of contents
Summary of the content on the page No. 1






BOILER & WATER HEATER
ELECTRONIC CONTROLLER


USER MANUAL



UPPER LED READOUT LED ICONS

LOWER LED READOUT








PVI Industries, LLC • 3209 Galvez Dr • Fort Worth, Texas 76111 • 800/784-8326
Page 1 / 6 PV500-40 01/25/11

Summary of the content on the page No. 2

1. DISPLAY AND INTERFACE 1.1 KEYBOARD BUTTONS - Displays and modifies the temperature set points. - In programming mode, it selects a parameter or confirms an operation. SET - Displays and modifies the energy saving (Night Time setback) settings. - In programming mode, it browses the parameter codes or increases a displayed value. UP - Displays the working hours of the load relays. - In programming mode, it browses the parameter codes or decreases a displayed value. DOWN -

Summary of the content on the page No. 3

1.4 UPPER LED READOUT The default display of this readout is the temperature sensed at Probe 2. In a Boiler, Probe 2 will be inserted into the outlet area and can control the outlet temperature. In a Water Heater, Probe 2 will be inserted into the appropriate area of the storage tank to provide effective temperature response for the heat source (this may not be at the top of the tank). By pressing and releasing the button once, the Upper LED will display the actual temperature sensed

Summary of the content on the page No. 4

1.8 TO SET MODULATION PARAMETERS Contact factory for detailed TempTrac instructions. 2. PROGRAMMING 2.1 SETPOINT DESCRIPTIONS AND PROGRAMMING Setpoints are those temperature or operating parameters that the user can adjust. St 1 - This setpoint temperature should be considered the °F or °C temperature threshold to activate the burner. The setpoint corresponds directly to the temperature sensed by probe 1. The St 1 setpoint is programmed as an absolute temperature; for exampl

Summary of the content on the page No. 5

2.2 HOW TO LOCK THE KEYBOARD 1. Push and hold the UP + DOWN keys for more than 3 seconds. 2. The “POF” message will be displayed and the keyboard is locked. At this point it is only possible to view the set point. 3. Repeat step 1 to unlock the keyboard. 2.3 HOT KEY PROGRAMMING (FOR FACTORY SUPPORTED FIELD REPROGRAMMING) To upload a program from a control to a HOT KEY: Insert HOT KEY into the TTL connection on the back of the control. Press and hold UP + DOWN keys moment

Summary of the content on the page No. 6

3.1 BUZZER The TempTrac buzzer is activated each time connected alarm condition happens. The following are representative alarm conditions that may be connected to and activate the TempTrac buzzer (some alarms may be connected to and operate separately from the TempTrac on some products).  High/low water temperature alarm  Probe failures  High and low gas pressure  Low water The buzzer is silenced by pressing any button (alarm condition still present) 3.2 ALARM RECOVERY


Alternative user manuals
# User manual Category Download
1 PVI Industries PV 6114 6/03 1 User manual Boiler 0
2 PVI Industries PV 9-A User manual Boiler 0
3 PVI Industries PV 6454 3/04 1 User manual Boiler 0
4 Sony HDV 1080I HVR-M15N/M15P User manual Boiler 67
5 Sony HDV 1080I HVR-M25N/M25P User manual Boiler 50
6 A.O. Smith 200 User manual Boiler 2
7 A.O. Smith 201 User manual Boiler 7
8 A.O. Smith 750 & 1000 User manual Boiler 6
9 A.O. Smith GB/GW-400 User manual Boiler 10
10 A.O. Smith DB/DW-720-1810 User manual Boiler 1
11 A.O. Smith DB-720 thru 1810 User manual Boiler 0
12 A.O. Smith GB/GW-650 User manual Boiler 3
13 A.O. Smith GB/GW-500 User manual Boiler 5
14 A.O. Smith GB/GW-200 User manual Boiler 2
15 A.O. Smith ACGSS02307 User manual Boiler 0