Summary of the content on the page No. 1
PA-2400/PA-2500
Connection Method For File Transfer
Manual
(Version 1.00 )
March 1998
Casio Computer Co., Ltd.
Copyright ©1998. All rights reserved.
Summary of the content on the page No. 2
Table of Contents Chapter 1. Overview 3 Chapter 2. Installation 4 2.1 Installation of PC 4 2.1.1 Connection 4 2.1.2 Start Up 4 2.1.3 Environment Setup 5 2.2 Direct Connection of H/PC to Host PC 6 2.3 Connection of H/PC to Host PC via I/O Box 6 2.4 Installation of Satellite I/O Box (1 unit) 7 2.5 Installation of Satellite I/O Box (multiple units) 8 Chapter 3. File Transmission/Reception 9 3.1 File Upload 9 3.1.1 Specifying File from PC Side 9 3.1.2 Specifying File from H/PC Side 11 3.2 File Downl
Summary of the content on the page No. 3
1. Overview This manual describes the connection method for implementing file transfers between a Host PC (Windows-version Upload/Download Utility) and PA-2400/PA-2500 (hereinafter referred to as H/PC). Only the PA-2400 can be connected via a Satellite I/O Box. Fig. 1.1 Example of Connection via Satellite I/O Box RS-232C IrDA Satellite PA-2400 PC HOST I/O Box RS-422 IrDA Satellite PA-2400 I/O Box RS-422 IrDA Satellite PA-2400 I/O Box Fig. 1.2 Example of Direct Connection of H/PC to Host PC
Summary of the content on the page No. 4
2. Installation 2.1 Installation of PC 2.1.1 Connection Plug Note: 2.1.2 Start Up 4 Utility Main Menu Screen Upload/Download Fig. 2.1 Make sure that the main menu screen of the Upload/Download Utility appears. Turn on the power to the PC to boot Windows95, then execute the Upload/Download Utility. for connection via the I/O Box. There are two types of connection cables: one is for direct connection to an H/PC, and the other is the connection cable into the COM1 connector of the Host P
Summary of the content on the page No. 5
2.1.3 Environment Setup “ ” Fig. Environment Note: 5 rate" entry field, depending on the state of the PC at that point in time. The maximum baud rate that is achieved in communication may differ from the setting in the "Baud Click on the [OK] button if setup has been completed. Set up appropriate conditions by comparing them to the data described above. Setup Screen 2.2 .. Settings Select "RS-232C" from the Configure menu of the Upload/Download Utility, and then select
Summary of the content on the page No. 6
2.2 Direct Connection of H/PC to Host PC Connection Plug the communication cable into the 16-pin interface of the H/PC to connect the Host PC. Start-up Turn on the power of the H/PC. 2.3 Connection of H/PC to Host PC via I/O Box Connection Mount the H/PC on the I/O Box. Start-up Turn on the power of the H/PC. 6
Summary of the content on the page No. 7
2.4 Installation of Satellite I/O Box (1 unit) Environment Setup 1) Make sure that the POWER switch of the I/O Box is set to OFF. 2) Set the DIP switches provided on the rear panel to the following. Table 2.1 1 2 3 4 567 89 10 ON OFF OFF OFF ON OFF ON ON ON ON Note: The above settings assume that the communication speed is set to 115,200 bps. To set a different baud rate modify the SW6, SW7, and SW8 settings as follows: Table 2.2 Baud Rate SW6 SW7 SW8 9,600 bps OFF ON OFF 19,200 bps ON
Summary of the content on the page No. 8
2.5 Installation of Satellite I/O Box (multiple units) Note that the DIP switch settings should be made according to whether the I/O Box is connected directly to the PC or daisy-chained to other I/O Boxes. The following environment setup example assumes a baud rate of 115.2 Kbps has been set. Environment setup 1) Make sure that the POWER switch is set to OFF. 2) Set the DIP switches of the I/O Box to be connected with the PC as follows. Table 2.3 1 2 3 4 567 89 10 ON OFF OFF OFF OFF OFF ON O
Summary of the content on the page No. 9
3. File Transmission/Reception 3.1 File Upload Transfers the files on the H/PC to the PC side. 3.1.1 Specifying File from PC Side Setup at Host PC Initiate the Upload/Download Utility on the PC, then select "Command" from the "Execute" menu to invoke the Communication Command screen. Fig. 3.1 Communication Command Screen In the Communication Command screen set up the following communication options: Set the "Command" field to "Receive". In the "File" field enter the pathname of a fi
Summary of the content on the page No. 10
Setup at H/PC Execute "Run by specifying the file name" of the Start menu on the H/PC. Fig. 3.2 H/PC File Name Specification Screen Enter the following commands, according to the connection method used with the Host PC, and click on the [OK] button. If I/O Box is used : Windows flce.exe If RS-232C cable is used: Windows flce.exe /Y={com1, 115200, } (baud rate: 115.2 Kbps) Creation of the above described shortcut enables start-up from the shortcut. If the [OK] button is clicked on,
Summary of the content on the page No. 11
3.1.2 Specifying File from H/PC Side Setup at Host PC Server 11 Mode Screen Fig. 3.4 menu. LinkManager" from the "Execute" Initiate the Upload/Download Utility on the PC, then select "
Summary of the content on the page No. 12
Setup at H/PC Execute "Run by specifying the file name" from the Start menu on the H/PC. Fig. 3.5 H/PC File Name Specification Screen Enter the following commands, according to the connection method used with the host PC, and click on the [OK] button. The following example command assumes that the "a.dat" file on the H/PC is transmitted to the drive C: on the Host PC. If I/O Box is used : Windows flce.exe /s " a.dat" "C: " If RS-232C cable is used: Windows flce.exe /Y={com1,
Summary of the content on the page No. 13
For information about the File Transfer Utility refer to the C Library Manual. If connecting via the I/O Box, mount the PA-2400 on the I/O Box. If the setup has been completed, the PA-2400 restores the screen that was displayed before the utility was initiated. 3.2 File Download Transfers the files on the Host PC to the H/PC side. 3.2.1 Specifying File from PC Side Setup at Host PC Select "Command" from the "Execute" menu of the Upload/Download Utility to invoke the Communication Command scre
Summary of the content on the page No. 14
Setup at H/PC Execute "Run by specifying the file name" from the Start menu on the H/PC. Fig. 3.8 H/PC File Name Specification Screen Enter the following commands, according to the connection method used with the Host PC, and click on the [OK] button. If I/O Box is used : Windows flce.exe If RS-232C cable is used: Windows flce.exe /Y={com1, 115200, } Creation of the above described shortcut enables start-up from the shortcut. If the [OK] button is clicked on, the following
Summary of the content on the page No. 15
3.2.2 Specifying File from H/PC Side Setup at Host PC Server 15 Mode Screen Fig. 3.10 menu. LinkManager" from the "Execute" Initiate the Upload/Download Utility on the Host PC, then select " was initiated. If the setup has been completed, the PA-2400 restores the screen that was displayed before the utility If connecting via the I/O Box, mount the PA-2400 on the I/O Box. For information about the File Transfer Utility refer to the C Library Manual.
Summary of the content on the page No. 16
Setup at H/PC Execute "Run by specifying the file name" from the Start menu on the H/PC. Fig. 3.11 H/PC File Name Specification Screen Enter the following commands, according to the connection method used with the host PC, and click on the [OK] button. The following example command assumes that the "C: a.dat" file on the PC is received under the " " directory on the H/PC side. If I/O Box is used : Windows flce.exe /r "C: a.dat" " " If RS-232C cable is used: Windows flce.e
Summary of the content on the page No. 17
For information about the File Transfer Utility refer to the C Library Manual. If connecting via the I/O Box, mount the PA-2400 on the I/O Box. If the setup has been completed, the PA-2400 restores the screen that was displayed before the utility was booted up. 17