Lochinvar SYNC 1.0 user manual

User manual for the device Lochinvar SYNC 1.0

Device: Lochinvar SYNC 1.0
Category: Boiler
Manufacturer: Lochinvar
Size: 1.64 MB
Added : 9/18/2013
Number of pages: 16
Print the manual

Download

How to use this site?

Our goal is to provide you with a quick access to the content of the user manual for Lochinvar SYNC 1.0. Using the online preview, you can quickly view the contents and go to the page where you will find the solution to your problem with Lochinvar SYNC 1.0.

For your convenience

If looking through the Lochinvar SYNC 1.0 user manual directly on this website is not convenient for you, there are two possible solutions:

  • Full Screen Viewing - to easily view the user manual (without downloading it to your computer), you can use full-screen viewing mode. To start viewing the user manual Lochinvar SYNC 1.0 on full screen, use the button Fullscreen.
  • Downloading to your computer - You can also download the user manual Lochinvar SYNC 1.0 to your computer and keep it in your files. However, if you do not want to take up too much of your disk space, you can always download it in the future from ManualsBase.
Lochinvar SYNC 1.0 User manual - Online PDF
Advertisement
« Page 1 of 16 »
Advertisement
Print version

Many people prefer to read the documents not on the screen, but in the printed version. The option to print the manual has also been provided, and you can use it by clicking the link above - Print the manual. You do not have to print the entire manual Lochinvar SYNC 1.0 but the selected pages only. paper.

Summaries

Below you will find previews of the content of the user manuals presented on the following pages to Lochinvar SYNC 1.0. If you want to quickly view the content of pages found on the following pages of the manual, you can use them.

Abstracts of contents
Summary of the content on the page No. 1

User’s Information Manual
Models: 1.0 - 1.3 - 1.5
WARNING: If the information in these instructions is not
followed exactly, a fire or explosion may result causing property
damage, personal injury or death.
-- Do not store or use gasoline or other flammable vapors and
liquids in the vicinity of this or any other appliance.
-- WHAT TO DO IF YOU SMELL GAS
� Do not try to light any appliance.
� Do not touch any electrical switch; do not use any phone in your
building.
� Immediately call your gas

Summary of the content on the page No. 2

Contents HAZARD DEFINITIONS . . . . . . . . . . . . . . . . . . . . . . . . . . 2 3. OPERATING INSTRUCTIONS . . . . . . . . . . . . . . . . . . . 9 PLEASE READ BEFORE PROCEEDING . . . . . . . . . . . . 3 4. SMART TOUCH CONTROL MODULE 1. PREVENT COMBUSTION AIR CONTAMINATION . . . 4 SYNC Control Module . . . . . . . . . . . . . . . . . . . . . . . . 10 2. MAINTENANCE SCHEDULE . . . . . . . . . . . . . . . . . . . . 5 Status Screen . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1

Summary of the content on the page No. 3

User’s Information Manual Please read before proceeding The SYNC Installation and Operation Boiler service and maintenance – NOTICE Manual along with the SYNC Service � To avoid electric shock, disconnect electrical supply Manual are for use only by a qualified before performing maintenance. heating installer/service technician. Refer only to this User’s Information � To avoid severe burns, allow boiler to cool before Manual for your reference. Improper performing maintenance. installation,

Summary of the content on the page No. 4

User’s Information Manual 1 Prevent combustion air contamination If the boiler combustion air inlet is located  WARNING Table 1A Corrosive Contaminants and Sources in any area likely to cause contamination, or if products which would contaminate Products to avoid: the air cannot be removed, you must have the combustion air and vent re-piped and Spray cans containing chloro/fluorocarbons terminated to another location. Permanent wave solutions Contaminated combustion air will damage the boiler,

Summary of the content on the page No. 5

User’s Information Manual 2 Maintenance schedule Service technician Owner maintenance (see the SYNC Service Manual) (see pages 6 - 8 for detailed instructions) General: • Address reported problems, if any • Check boiler area • Inspect interior; clean and vacuum if necessary; Daily • Check pressure/temperature • Clean condensate trap and fill with fresh gauge water •Check for leaks (water, gas, flue, condensate) • Verify flue and air lines in good condition and sealed tight • Check vent pi

Summary of the content on the page No. 6

User’s Information Manual 2 Maintenance schedule Read the list of potential materials listed in Table 1A on Maintenance procedures page 4 of this manual. If any of these products are in the room from which the boiler takes its combustion air, they Boiler must be serviced and maintained must be removed immediately or the boiler combustion air (and vent termination) must be relocated to another The boiler must be inspected and started  WARNING area. annually at the beginning of the heating

Summary of the content on the page No. 7

User’s Information Manual 2 Maintenance schedule (continued) 3. Fill with fresh water until the water begins to pour out Use materials approved by the authority NOTICE of the drain. having jurisdiction. In the absence of other authority, PVC and CPVC pipe must 4. Replace the cap. Press the cap onto the trap until the comply with ASTM D1785 or D2845. cap makes contact with the drain. Cement and primer must comply with 5. Replace the retaining screw. ASME D2564 or F493. For Canada use CSA or

Summary of the content on the page No. 8

User’s Information Manual 2 Maintenance schedule Check automatic air vents Have leaks fixed at once by a qualified  WARNING service technician. Failure to comply could 1. Reference FIG. 2-3 below. result in severe personal injury, death, or substantial property damage. 2. Remove the caps (FIG. 2-3 – “A”) from the automatic air 3. Replace the front access door. vents in the system and check operation by slightly depressing valve “B” (FIG. 2-3) with the tip of a Operate relief valve screwdri

Summary of the content on the page No. 9

User’s Information Manual 3 Operating instructions FOR YOUR SAFETY READ BEFORE OPERATING WARNING: If you do not follow these instructions exactly, a fire or explosion may result causing property damage, personal injury, or loss of life. A. This appliance does not have a pilot. It is • Immediately call your gas supplier from a equipped with an ignition device which neighbor’s phone. Follow the gas supplier’s automatically lights the burner. Do not try instructions. to light the burne

Summary of the content on the page No. 10

User’s Information Manual 4 SMART TOUCH control module SYNC control module The Status Screen displays boiler status, Cascade addresses, outlet water temperature, inlet water temperature, system temperature, and tank temperature. The boiler can be changed by pressing the ON/OFF button. The Details Screen and Main Menu Screen can be accessed by pressing the appropriate button. Figure 4-1 Status Screen When the ON/OFF switch is turned to the ON position, the � SH BMS - The boiler has received a c

Summary of the content on the page No. 11

User’s Information Manual 4 SMART TOUCH control module (continued) Hot Water Tank Temperature - This is the temperature as Boiler Configuration - This line shows the current measured by the tank sensor in the hot water storage tank. configuration of the two control modules inside the unit. Time - The time is displayed in the upper right-hand corner of Outlet Water Temperature - This is a calculated temperature the display. It is displayed in 24 hour format. Reference the based on the readings

Summary of the content on the page No. 12

User’s Information Manual 4 SMART TOUCH control module Figure 4-2 Details Screen � Alarm - Is ON when a fault has been detected and the The Details Screen is accessed by pressing the DETAIL button alarm contacts are closed. Is OFF when the alarm on the Status Screen. This screen shows the status of the contacts are open. various safeties, inputs and outputs to each control module. � Louver Proving Switch - Is ON when a remote proving Selection of the control module to be viewed is accompli

Summary of the content on the page No. 13

User’s Information Manual 4 SMART TOUCH control module (continued) A blank message box is located on the Details Screen. This Time - The time is displayed in the upper right-hand corner of box will display various messages detailing the status of the the display. It is displayed in 24 hour format. Reference the control module. If a message is present in this box, the night setback parameters in the SYNC Service Manual for DETAILS button on the Status Screen will contain a yellow information

Summary of the content on the page No. 14

User’s Information Manual 4 SMART TOUCH control module Use the Main Menu Screen (FIG. 4-3) to access the screens necessary to set temperatures, operating conditions, and monitor boiler operation. The SYNC is equipped with a SMART TOUCH control system. All menu options are accessed by touching the screen with your finger or a stylus from a PDA. Figure 4-3 Main Menu Screen The Main Screen allows navigation to eight (8) additional Navigation to the Main Screen can be accomplished by pressing scre

Summary of the content on the page No. 15

Notes 15

Summary of the content on the page No. 16

Revision Notes: Revision A (ECO #C02428) initial release. SYNC-USER Rev A 10/08


Alternative user manuals
# User manual Category Download
1 Lochinvar 000 - 260 User manual Boiler 4
2 Lochinvar 051-211 User manual Boiler 0
3 Lochinvar 1 User manual Boiler 0
4 Lochinvar 000 through 2 User manual Boiler 2
5 Lochinvar 000 BTU/HR User manual Boiler 5
6 Lochinvar 1.3 User manual Boiler 0
7 Lochinvar 0402-0752 User manual Boiler 1
8 Lochinvar 1.5 User manual Boiler 0
9 Lochinvar 2001 User manual Boiler 0
10 Lochinvar 2 User manual Boiler 0
11 Lochinvar 151 User manual Boiler 0
12 Lochinvar 1701 User manual Boiler 0
13 Lochinvar 151-286 User manual Boiler 0
14 Lochinvar 2.5 User manual Boiler 0
15 Lochinvar 45 User manual Boiler 0
16 Sony HDV 1080I HVR-M15N/M15P User manual Boiler 67
17 Sony HDV 1080I HVR-M25N/M25P User manual Boiler 50
18 A.O. Smith 200 User manual Boiler 2
19 A.O. Smith 201 User manual Boiler 7
20 A.O. Smith 750 & 1000 User manual Boiler 6