Lochinvar KNIGHT WH 55 - 399 user manual

User manual for the device Lochinvar KNIGHT WH 55 - 399

Device: Lochinvar KNIGHT WH 55 - 399
Category: Boiler
Manufacturer: Lochinvar
Size: 1.38 MB
Added : 9/26/2014
Number of pages: 16
Print the manual

Download

How to use this site?

Our goal is to provide you with a quick access to the content of the user manual for Lochinvar KNIGHT WH 55 - 399. Using the online preview, you can quickly view the contents and go to the page where you will find the solution to your problem with Lochinvar KNIGHT WH 55 - 399.

For your convenience

If looking through the Lochinvar KNIGHT WH 55 - 399 user manual directly on this website is not convenient for you, there are two possible solutions:

  • Full Screen Viewing - to easily view the user manual (without downloading it to your computer), you can use full-screen viewing mode. To start viewing the user manual Lochinvar KNIGHT WH 55 - 399 on full screen, use the button Fullscreen.
  • Downloading to your computer - You can also download the user manual Lochinvar KNIGHT WH 55 - 399 to your computer and keep it in your files. However, if you do not want to take up too much of your disk space, you can always download it in the future from ManualsBase.
Lochinvar KNIGHT WH 55 - 399 User manual - Online PDF
Advertisement
« Page 1 of 16 »
Advertisement
Print version

Many people prefer to read the documents not on the screen, but in the printed version. The option to print the manual has also been provided, and you can use it by clicking the link above - Print the manual. You do not have to print the entire manual Lochinvar KNIGHT WH 55 - 399 but the selected pages only. paper.

Summaries

Below you will find previews of the content of the user manuals presented on the following pages to Lochinvar KNIGHT WH 55 - 399. If you want to quickly view the content of pages found on the following pages of the manual, you can use them.

Abstracts of contents
Summary of the content on the page No. 1

WH-USER Rev B
User’s Information Manual
Models: WH 55 - 399
 WARNING
If the information in this manual is not followed exactly, a fire or
explosion may result causing property damage, personal injury or
loss of life.
This appliance MUST NOT be installed in any location where
gasoline or flammable vapors are likely to be present.
WHAT TO DO IF YOU SMELL GAS
� Do not try to light any appliance.
� Do not touch any electric switch; do not use any phone in your
building.
� Immediately call you

Summary of the content on the page No. 2

Contents HAZARD DEFINITIONS ..................................................... 2 3. OPERATING INSTRUCTIONS ..................................... 9 PLEASE READ BEFORE PROCEEDING ......................... 3 4. SMART SYSTEM CONTROL MODULE 1. PREVENT COMBUSTION AIR CONTAMINATION ..... 4 SMART SYSTEM Control Module ................................... 11 2. MAINTENANCE SCHEDULE ....................................... 5 Access Modes ..........................................................

Summary of the content on the page No. 3

User’s Information Manual Please read before proceeding The Knight Wall Mount Installation and Boiler service and maintenance – NOTICE Operation Manual along with the Knight � To avoid electric shock, disconnect electrical supply Wall Mount Service Manual are for use before performing maintenance. only by a qualified heating installer/service technician. Refer only to this User’s � To avoid severe burns, allow boiler to cool before Information Manual for your reference.

Summary of the content on the page No. 4

User’s Information Manual 1 Prevent combustion air contamination If the boiler combustion air inlet is located  WARNING Table 1A Corrosive Contaminants and Sources in any area likely to cause contamination, or if products which would contaminate Products to avoid: the air cannot be removed, you must have the combustion air and vent Spray cans containing chloro/fluorocarbons re-piped and terminated to another Permanent wave solutions location. Contaminated combustion air w

Summary of the content on the page No. 5

User’s Information Manual 2 Maintenance schedule Service technician Owner maintenance (see the Knight Wall Mount Service Manual) (see pages 6 - 8 for detailed instructions) General: • Reported problems • Check boiler area • Inspect interior; clean and vacuum if Daily • Check pressure/temperature necessary gauge • Clean condensate trap and fill with fresh water • Check for leaks (water, gas, flue, condensate) • Check vent piping • Verify flue and air lines

Summary of the content on the page No. 6

User’s Information Manual 2 Maintenance schedule Read the list of potential materials listed in Table 1A on Maintenance procedures page 4 of this manual. If any of these products are in the room from which the boiler takes its combustion air, they Boiler must be serviced and maintained must be removed immediately or the boiler combustion air (and vent termination) must be relocated to another The boiler must be inspected and started  WARNING area. annually at the begi

Summary of the content on the page No. 7

User’s Information Manual 2 Maintenance schedule (continued) The condensate trap (FIG. 2-1) must have Use materials approved by the authority NOTICE  WARNING the float ball in place during all times of having jurisdiction. In the absence of boiler operation to avoid flue gas emission other authority, PVC and CPVC pipe from the condensate drain line. Failure to must comply with ASTM D1785 or D2845. ensure the float ball is in place could result in Cement and primer m

Summary of the content on the page No. 8

User’s Information Manual 2 Maintenance schedule Test low water cutoff (if installed) 1. If the system is equipped with a low water cutoff, 2. Read the boiler pressure/temperature gauge to make test the low water cutoff periodically during the heating sure the system is pressurized. Lift the relief valve season, following the low water cutoff manufacturer’s top lever slightly, allowing water to relieve through instructions. the valve and discharge piping. 3. If wa

Summary of the content on the page No. 9

User’s Information Manual 3 Operating instructions Figure 3-1 Operating Instructions - Models 55 - 285 o 9

Summary of the content on the page No. 10

User’s Information Manual 3 Operating instructions Figure 3-2 Operating Instructions - Model 399 10

Summary of the content on the page No. 11

User’s Information Manual 4 SMART SYSTEM control module Knight wall mount control module Use the control panel (FIG. 4-1) to set temperatures, operating conditions, and monitor boiler operation. Figure 4-1 Control Panel NAVIGATION DIAL The information on the bottom of the display shows the functions of the two SELECT keys (on either corner), and the NAVIGATION dial (in the center): MENU = Left SELECT Key SETPOINTS = NAVIGATION Dial - Pressing Down SHDN = Right SELEC

Summary of the content on the page No. 12

User’s Information Manual 4 SMART SYSTEM control module Night Setback Override Space heating (SH1, SH2, SH3) and tank set points Any Night Setback On trigger currently active or scheduled Mixing valves are required for the CAUTION within the next seven (7) days can be skipped. To skip a trigger, protection of any low temperature loops. press the MENU key for 5 seconds. Once password “0000” appears, press the SAVE key. Rotate the NAVIGATION dial to NSB OVERRIDE, and press

Summary of the content on the page No. 13

User’s Information Manual 4 SMART SYSTEM control module (continued) Figure 4-2 Status Display Screen B A (CALL FOR (BOILER HEAT) STATUS) C (OPERATIONAL INFORMATION) F D (RIGHT SELECT KEY) (LEFT SELECT KEY) E (NAVIGATION DIAL) Status Display Screens Section Display Description The unit has not received a call for heat from a remote thermostat nor STANDBY has it received a call for heat from a DHW thermostat. START The unit has begun a burn cycle and is checking all safety circui

Summary of the content on the page No. 14

User’s Information Manual 4 SMART SYSTEM control module Status Display Screens (cont’d) Section Display Description SYSTEM: The temperature read by the system supply sensor (if connected). TANK: The temperature read by the tank sensor (if connected). OUTDOOR: The temperature read by the outdoor sensor (if connected). INLET TEMP: The temperature read at the inlet to the heat exchanger. OUTLET TEMP: The temperature read at the outlet of the heat exchanger. The temperature differen

Summary of the content on the page No. 15

User’s Information Manual 4 SMART SYSTEM control module (continued) Status Display Screens (cont’d) Section Display Description Turning the NAVIGATION dial will select the next or previous Status Screen. Pressing the NAVIGATION dial will show the next fault, NSB (Night Setback) trigger, or ramp delay setting. Pressing the NAVIGATION dial will select the setting indicated by E the cursor. (NAVIGATION Pressing the NAVIGATION dial will display the Set Points Screen. Dial Functio

Summary of the content on the page No. 16

Revision Notes: Revision A (ECO C06854) initial release. Revision B (ECO C07072) reflects the update of the User information in the SMART SYSTEM control module “Access modes” section on page 11 and user information in the “Night Setback Override” section on page 12. WH-USER Rev B 01/11


Alternative user manuals
# User manual Category Download
1 Lochinvar 000 - 260 User manual Boiler 4
2 Lochinvar 051-211 User manual Boiler 0
3 Lochinvar 1 User manual Boiler 0
4 Lochinvar 000 through 2 User manual Boiler 2
5 Lochinvar 000 BTU/HR User manual Boiler 5
6 Lochinvar 1.3 User manual Boiler 0
7 Lochinvar 0402-0752 User manual Boiler 1
8 Lochinvar 1.5 User manual Boiler 0
9 Lochinvar 2001 User manual Boiler 0
10 Lochinvar 2 User manual Boiler 0
11 Lochinvar 151 User manual Boiler 0
12 Lochinvar 1701 User manual Boiler 0
13 Lochinvar 151-286 User manual Boiler 0