RuggedMAX WiN7000 RuggedMAX WiN7000 : Installation Guide Copyright © 2010 RuggedCom Inc. All Rights Reserved Dissemination or reproduction of this document, or evaluation and communication of its contents, is not authorized except where expressly permitted. Violations are liable for damages. All rights are reserved, particularly for the purposes of patent application or trademark registration. This document contains proprietary information, which is protected by copyright. All rights are reserve
Summary of the content on the page No. 3
RuggedMAX WiN7000 Table of Contents FCC Statement And Cautions ................................................................................................... 6 1. Introduction ............................................................................................................................ 7 1.1. About this Guide ......................................................................................................... 7 1.2. Capabilities and Features ...............................
Summary of the content on the page No. 4
RuggedMAX WiN7000 List of Figures 1.1. Typical Centralized DC Power System, Plant and Distribution Source-Grounded DC Power System .......................................................................................................................... 10 1.2. Typical Centralized DC Power System, Plant and Distribution DC Power System Grounded at Equipment Location ............................................................................................ 10 1.3. Win7000 Dimensions ...........
Summary of the content on the page No. 5
RuggedMAX WiN7000 List of Tables 3.1. WiN7000 Pole Mount Parts List ....................................................................................... 18 3.2. WiN7000 Wall Mount Parts List ........................................................................................ 19 3.3. WiN7000 Connectors and Cables .................................................................................... 21 3.4. +48 VDC Power System .................................................................
Summary of the content on the page No. 6
FCC Statement And Cautions FCC Statement And Cautions Federal Communications Commission Radio Frequency Interference Statement This equipment has been tested and found to comply with the limits for a Class A digital device pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment. This equipment generates, uses and can radiate radio frequency energy and, if not installed
Summary of the content on the page No. 7
1. Introduction 1. Introduction The WiN7000 is a member of the RuggedMAX™ family, a line of mobile WiMAX broadband wireless access systems based on the 802.16e mobile WiMAX standard. RuggedMAX systems are designed for robustness and simplicity, offering feature-rich services with low deployment and operation costs. The WiN7000 base station is a cost-effective solution for wireless access services, designed for point-to-multipoint broadband wireless access applications in varying conditions and l
Summary of the content on the page No. 8
1. Introduction 1.2. Capabilities and Features The WiN7000 provides the full base station functionality necessary for serving a single sector: • All-outdoor, single-box installation • IEEE802.16e Wave2 Standard Compliance • Backbone Ethernet connectivity via a 10/100 Base-T network interface • Fixed and mobile CPE support • 3.5 MHz, 5MHz, 7MHz and 10MHz channel bandwidth support • MIMO (2×2) support • Various Radio Frequency (RF) options, including 1.x, 2.x and 3.x GHz band support • Traffic cla
Summary of the content on the page No. 9
1. Introduction 1.3. Safety Information 1.3.1. General • Read this user manual and follow all operating and safety instructions. • The base station and antenna must be installed by a professional installer. • Do not exceed the described limits. 1.3.2. Power Supply Requirements • The power supply unit should be a Class 2 power supply, safety-certified according to national codes. • Maximum output current should not exceed 5A. • Maximum output voltage of the power supply should not exceed 60VDC. •
Summary of the content on the page No. 10
1. Introduction Figure 1.1. Typical Centralized DC Power System, Plant and Distribution Source-Grounded DC Power System Figure 1.2. Typical Centralized DC Power System, Plant and Distribution DC Power System Grounded at Equipment Location RuggedCom® RuggedMAX WiN7000 10 Installation Guide Rev1
Summary of the content on the page No. 11
1. Introduction 1.3.3. Equipment Installation Install the equipment in accordance with the electrical code relevant to the country of installation, such as the National Electrical Code (NEC), ANSI/NFPA 70; the Canadian Electrical Code (CEC), Part 1, CSA C22.1; and when applicable, the National Electrical Safety Code IEEE C2. Unless marked or otherwise identified, the Standard for the Protection of Electronic Computer/Data Processing Equipment, ANSI/NFPA 75, also applies. 1.3.4. Radio Frequency (
Summary of the content on the page No. 12
1. Introduction 1.3.8. Antenna Grounding Requirements The antenna installation must be as per Article 810 of the NEC. Of particular note is the requirement that the grounding conductor not be less than 10 AWG (Cu). The scheme should be either in accordance with UL 96 and 96A Lightning Protection Components and Installation Requirements for Lightning Protection Systems, or tested in accordance with UL 50 and UL 497. 1.3.9. Outdoor Grounding System Verify that the base station is grounded. The sys
Summary of the content on the page No. 13
1. Introduction 1.4. WiN7000 Physical Specifications The WiN7000 outdoor base station is packed in a waterproof metal housing. A mounting bracket and mounting kit allows for pole or wall installation. The assembled unit weighs approximately 15kg. For information on the WiN7000 wiring connections, see Section 3.4.5, “Cable Connections”. Figure 1.3. Win7000 Dimensions RuggedCom® RuggedMAX WiN7000 13 Installation Guide Rev1
Summary of the content on the page No. 14
2. Site and Installation Requirements 2. Site and Installation Requirements 2.1. Mounting Considerations When choosing a mounting location, consider the available mounting structures and antenna clearance. To provide better weather protection, the WiN7000 should be mounted with the connection panel facing downwards. The base station is equipped with a mounting kit, which allows several mounting options: • Poles: Attach the WiN7000 to any pipe or pole with diameter 1.75" to 10". • Towers and Wall
Summary of the content on the page No. 15
3. Installation Procedures 3. Installation Procedures 3.1. Pre-Installation Safety Instructions Installing the WiN7000 can pose a serious hazard. Be sure to take precautions to avoid the following: • Exposure to high voltage lines during installation • Falling when working at heights or with ladders • Injuries from dropping tools • Contact with AC wiring (power system connection) 3.2. Package Components and Unpacking Check that the package contains: • WiN7000 WiMax Base Station. • GPS antenna •
Summary of the content on the page No. 16
3. Installation Procedures 3.4. Installing the WiN7000 The equipment should be installed in compliance with the National Electrical Code (NEC), ANSI/NFPA 70, the Canadian Electrical Code (CEC), Part 1, CSA C22.1; and when applicable, the National Electrical Safety Code IEEE C2. Unless marked or otherwise identified, the Standard for the Protection of Electronic Computer/Data Processing Equipment, ANSI/NFPA 75. The following components are required for the installation: • Mounting bracket • WiN70
Summary of the content on the page No. 17
3. Installation Procedures 3.4.1. WiN7000 Mounting Bracket The mounting bracket is used for both pole- and wall-mount installations. Figure 3.1. Mounting Bracket RuggedCom® RuggedMAX WiN7000 17 Installation Guide Rev1
Summary of the content on the page No. 18
3. Installation Procedures 3.4.2. Pole Mounting Figure 3.2. WiN7000 Pole Mounting Diagram Item Quantity Description 1 1 Mounting brackets 2 1 WiN7000 Base Station 3 2 Fastening brackets 4 4 Screw 5/16" hex cap × 6" 5 8 Nut NF 16 hex 6 10 Washer flat 5/16" 7 10 Washer spring 5/16" 8 4 Screw NC 1/4" × 1/2" hex 9 4 Washer flat NC 1/4" 10 4 Washer spring NC 1/4" 11 1 Pole 12 2 Bolt NC 1/4" 13 2 Screw NC 5/16" × 1/2" 14 1 Mounting Upper Bracket Table 3.1. WiN7000 Pole Mount Parts List Procedure 3.1.
Summary of the content on the page No. 19
3. Installation Procedures 3. Lift the base station by the eye bolts and secure it to the mounting bracket. At the top of the unit and mounting bracket, use NC 1/4" × 1/2" hex screws (Item 8) and NC 1/4" flat washers (Item 9). At the bottom of the unit and mounting bracket, use 5/16" flat washers (Item 6), 5/16" spring washers (Item 7), and NC 5/16" × 1/2" screws (Item 13). 4. Complete the wiring connections. Seal all connectors with self-fusing electrical tape or insulating putty suitable for u
Summary of the content on the page No. 20
3. Installation Procedures Procedure 3.2. Installing the WiN7000 on a Wall 1. Select a mounting location. 2. Place the mounting bracket on the wall and mark the location of the four mounting holes, two at the top and two at the bottom. 3. With a 5/16" drill bit suitable for the wall material, drill holes at the marked locations. 4. Insert the 5/16" dowels (Item 10) into the holes. 5. Assemble four 5/16" flat washers (Item 8), four 5/16" spring washers (Item 9), and four 5/16" × 2" hex cap screws