Summary of the content on the page No. 1
Models 2603, 2621, and 2635
OnSite Series High Speed Routers
User Manual
Important
This is a Class A device and is intended for use in a light industrial environment. It is not intended nor approved for use in an industrial
or residential environment.
Sales Office: +1 (301) 975-1000
Technical Support: +1 (301) 975-1007
E-mail: support@patton.com
WWW: www.patton.com
Document Number: 03328U1-001 Rev. C
Part Number: 07M2600Ser-GS
Summary of the content on the page No. 2
Patton Electronics Company, Inc. 7622 Rickenbacker Drive Gaithersburg, MD 20879 USA Tel: +1 (301) 975-1000 Fax: +1 (301) 869-9293 Support: +1 (301) 975-1007 Web: www.patton.com E-mail: support@patton.com Copyright © 2012, Patton Electronics Company. All rights reserved. The information in this document is subject to change without notice. Patton Elec- tronics assumes no liability for errors that may appear in this document. Warranty Information The software described in this document is furnishe
Summary of the content on the page No. 3
Summary Table of Contents 1 General Information...................................................................................................................................... 17 2 Product Overview.......................................................................................................................................... 24 3 Initial Configuration ..................................................................................................................................
Summary of the content on the page No. 4
Contents Summary Table of Contents ......................................................................................................................... 3 Contents ......................................................................................................................................................... 4 List of Figures ............................................................................................................................................... 10 List of Tabl
Summary of the content on the page No. 5
Contents Models 2603, 2621, and 2635 User Manual Installing an interface cable on the OnSite 2635’s V.35 interface port .......................................................33 Installing the AC power cord ..........................................................................................................................34 Installing the Ethernet cable ............................................................................................................................36 IP address
Summary of the content on the page No. 6
Models 2603, 2621, and 2635 User Manual Contents Remote Site Configuration .................................................................................................................63 Central site configuration ...................................................................................................................66 7 Security ........................................................................................................................................................
Summary of the content on the page No. 7
Contents Models 2603, 2621, and 2635 User Manual Website Settings ..................................................................................................................................................101 Error Log.............................................................................................................................................................102 SNMP Daemon ......................................................................................................
Summary of the content on the page No. 8
Models 2603, 2621, and 2635 User Manual Contents T1/E1 Interface ...................................................................................................................................................119 Protocol Support .................................................................................................................................................120 PPP Support..........................................................................................................
Summary of the content on the page No. 9
Contents Models 2603, 2621, and 2635 User Manual 9
Summary of the content on the page No. 10
List of Figures 1 OnSite Series Router (Model 2635 shown) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 20 2 Sync Serial Application . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 26 3 T1/E1 Application . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 26 4 Rear V
Summary of the content on the page No. 11
Models 2603, 2621, and 2635 User Manual 48 New Policy link to configuration webpage . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 73 49 Deleting a Security Policy . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 74 50 Defining ICMP port filter for ping . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Summary of the content on the page No. 12
List of Tables 1 General conventions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 16 2 Status LED descriptions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 20 3 LMI Implementation on the OnSite . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 58 4 Featur
Summary of the content on the page No. 13
About this guide This guide describes installing and configuring Patton Electronics OnSite Series High Speed Routers. The instructions in this guide are based on the following assumptions: • The router may connect to a serial DTE device or T1/E1 line • There is a LAN connected to the Ethernet port of the router Audience This guide is intended for the following users: • Operators • Installers • Maintenance technicians Structure This guide contains the following chapters and appendices: • Chapter
Summary of the content on the page No. 14
Models 2603, 2621, and 2635 User Manual About this guide Precautions Notes, cautions, and warnings, which have the following meanings, are used throughout this guide to help you become aware of potential problems. Warnings are intended to prevent safety hazards that could result in per- sonal injury. Cautions are intended to prevent situations that could result in property damage or impaired functioning. Note A note presents additional information or interesting sidelights. The alert symbol an
Summary of the content on the page No. 15
Models 2603, 2621, and 2635 User Manual About this guide Safety when working with electricity • This device contains no user serviceable parts. The equipment shall be returned to Patton Electronics for repairs, or repaired by qualified service personnel. • Mains Voltage: Do not open the case the when the power cord is attached. WARNING Line voltages are present within the power supply when the power cords are connected. The mains outlet that is utilized to power the devise shall be within 1
Summary of the content on the page No. 16
Models 2603, 2621, and 2635 User Manual About this guide Factory default parameters OnSite Series High Speed Routers have the following factory default parameters. • Ethernet IP address: 192.168.200.10/24 • WAN Connection: PPP Bridged • Ethernet and serial connections • MDI (LAN connector) • Model 2621 (X.21)—DB-15 port (DTE) • Model 2635 (V.35)—DB-25 port (DCE, DTE when using special V.35 cable) • Model 2603/T—T1 configuration. RJ-48C (100-ohm) interface • Model 2603/K—E1 configuration. RJ-48C
Summary of the content on the page No. 17
Chapter 1 General Information Chapter contents IPLink Series High Speed Routers overview ..........................................................................................................18 General attributes ............................................................................................................................................18 Ethernet ...................................................................................................................................
Summary of the content on the page No. 18
Models 2603, 2621, and 2635 User Manual 1 • General Information OnSite Series High Speed Routers overview The OnSite Series of gateway routers/bridges combine full set of high-speed IP routing features and WAN access via PPP/IP/FR protocols. All OnSite routers come with an auto-sensing full-duplex 10/100Base-T Ethernet port, MDI-X cross-over switch, console port, and internal or external power supply. There are three versions in the OnSite series corresponding to a choice of WAN interface: •
Summary of the content on the page No. 19
Models 2603, 2621, and 2635 User Manual 1 • General Information Ethernet • Auto-sensing full-duplex 10Base-T/100Base-TX Ethernet. • Standard RJ-45 connector • Built-in MDI-X cross-over switch. • IEEE 802.1d transparent learning bridge • 2 IP address/subnets on Ethernet interface. Protocol support • Complete internetworking with IP (RFC 741), TCP (RFC 793), UDP (RFC 768), ICMP (RFC 950), ARP (RFC 826). • IP router with RIP (RFC 1058), RIPv2 (RFC 2453) • Up to 64 static routes. • Built-in ping
Summary of the content on the page No. 20
Models 2603, 2621, and 2635 User Manual 1 • General Information • Logging via SYSLOG, and VT-100 console. Console port set at 9600 bps 8/N/1 settings no flow control. Security • Packet filtering firewall for controlled access to and from LAN/WAN. Support for 255 rules in 32 filter sets. 16 individual connection profiles. • DoS Detection/protection. Intrusion detection, Logging of session, blocking and intrusion events and Real- Time alerts. Logging or SMTP on event. • Password protected system