Honeywell L91B user manual

User manual for the device Honeywell L91B

Device: Honeywell L91B
Category: Boiler
Manufacturer: Honeywell
Size: 0.77 MB
Added : 8/23/2014
Number of pages: 12
Print the manual

Download

How to use this site?

Our goal is to provide you with a quick access to the content of the user manual for Honeywell L91B. Using the online preview, you can quickly view the contents and go to the page where you will find the solution to your problem with Honeywell L91B.

For your convenience

If looking through the Honeywell L91B user manual directly on this website is not convenient for you, there are two possible solutions:

  • Full Screen Viewing - to easily view the user manual (without downloading it to your computer), you can use full-screen viewing mode. To start viewing the user manual Honeywell L91B on full screen, use the button Fullscreen.
  • Downloading to your computer - You can also download the user manual Honeywell L91B to your computer and keep it in your files. However, if you do not want to take up too much of your disk space, you can always download it in the future from ManualsBase.
Honeywell L91B User manual - Online PDF
Advertisement
« Page 1 of 12 »
Advertisement
Print version

Many people prefer to read the documents not on the screen, but in the printed version. The option to print the manual has also been provided, and you can use it by clicking the link above - Print the manual. You do not have to print the entire manual Honeywell L91B but the selected pages only. paper.

Summaries

Below you will find previews of the content of the user manuals presented on the following pages to Honeywell L91B. If you want to quickly view the content of pages found on the following pages of the manual, you can use them.

Abstracts of contents
Summary of the content on the page No. 1

L91A,B,D Proportioning
®
Pressuretrol Controllers
PRODUCT DATA
FEATURES
• Models available for pressure systems up to 300 psi
(2068 kPa).
• May be used with steam, air, noncombustible gases, or
other fluids noncorrosive to brass or phos-bronze (300
psi model) bellows.
• When used with steam boilers, a steam trap (siphon
loop) is recommended.
• Wiper on controller potentiometer moves in response
to pressure changes.
• L91D has two potentiometers for unison control of two
motors.
• L91B,D mo

Summary of the content on the page No. 2

® L91A,B,D PROPORTIONING PRESSURETROL CONTROLLERS SPECIFICATIONS Table 1. Models available. Maximum Surge a Operating Ranges Proportioning (Throttling) Range at Midscale Pressure U. S. U. S. Potentiometer Customary Customary b Model Units Metric Units Part No. Adjustable Units Metric Units psi kPa L91A 0 to 15 psi 0 to 103 kPa 23176CB No 0.5 psi 3.4 kPa 25 172 5 to 150 psi 0.03 to 1.03 MPa 23176CB No 5 psi 0.03 MPa 225 1551 b 0.07 to 2.07 MPa 23176CB No 12 psi 0.08 MPa 350 2413 10 to 300 psi

Summary of the content on the page No. 3

® L91A,B,D PROPORTIONING PRESSURETROL CONTROLLERS Electrical Connections: Internal screw terminals. Hole inside 23176CF Potentiometer: For all L91D models and most L91B of case for 1/2 in. conduit. models (see Table 1); 140 ohms (nominal); length of active winding is 1/4 in. (6.4 mm). Dimensions: See Fig. 1; see Fig. 2 for mounting steam trap (siphon loop). Accessories: 50024585-001 Steam Trap (siphon loop): 1/4 in. brass pipe Weight: 1 lb, 15 oz (0.88 kg). with 1/4 -18 NPT external threads

Summary of the content on the page No. 4

® L91A,B,D PROPORTIONING PRESSURETROL CONTROLLERS 4-1/2 (114.3) (COVER) L91A,B,D (110.3) (CASE) 4-11/32 2-3/4 (69.9) (98.8) 3-57/64 3-13/32 (86.5) 1-3/16 (30.2) 1-5/32 (29.4) 3 4 1-1/16 (27.0) 2 2 3-23/32 1-3/32 (27.8) (94.5) 3-7/8 2-5/64 (98.4) (52.8) ALL OTHER DIM C (SEE MODELS 7/8 1-13/16 TABULATION (22.2) (2) (46.0) TABLE) 13/16 10 TO 300 PSI (20.1) 0 TO 15 PSI 2 0 TO 16 OZ/IN 1/4-18 NPT 1 1-1/16 2-1/8 (53.5) (27.0) DIM A (SEE TABULATION TABLE)

Summary of the content on the page No. 5

® L91A,B,D PROPORTIONING PRESSURETROL CONTROLLERS INSTALLATION When Installing This Product... L91 1. Read these instructions carefully. Failure to follow them PRESSURETROL could damage the product or cause a hazardous CONTROLLER condition. 2. Check the ratings given in the instructions and on the product to make sure the product is suitable for your PRESSURE GAUGE application. 3. Installer must be a trained, experienced service PRESSURETOL technician. 4. After installation is complete, check

Summary of the content on the page No. 6

® L91A,B,D PROPORTIONING PRESSURETROL CONTROLLERS 6. Refer to Fig. 4 for typical hookup. W and B connections may be interchanged at the motor for reverse action ACTION ON (cooling). Follow the burner or boiler manufacturer’s PRESSURE FALL wiring diagram if provided. Also refer to the wiring WB diagrams in the motor instructions. 7. Replace the front cover when wiring is completed. R 1 W SERIES 90 L91 PROPORTIONING MODULATING MOTOR CONTROLLER B M9484 CLOSED R W1 M9494 (LOW FIRE) 1 W R1 OPEN

Summary of the content on the page No. 7

® L91A,B,D PROPORTIONING PRESSURETROL CONTROLLERS point). The L91B settings provide system modulation between 70 and 75 psi or between 75 and 80 psi, depending on the MAIN SCALE PROPORTIONING RANGE exact setting of the L91B main scale setpoint. ADJUSTING ADJUSTING SCREW (L91B,D ONLY) SCREW CONTROLLER Due to device tolerances, the scaleplate settings are POTENTIOMETER 1 approximate and, therefore, the settings should be fine-tuned with the system operating. WIPER ARM(S) Proportioning Range (

Summary of the content on the page No. 8

® L91A,B,D PROPORTIONING PRESSURETROL CONTROLLERS CHECKOUT MAIN SCALE PROPOTIONING ADJUSTING SCREW RANGE ADJUSTING After the controller is installed, wired, and set, it should be SCREW 1 tested with the system in operation. First, allow the system to (L91B,D ONLY) stabilize. Then, observe the operation of the controller while raising and lowering its setpoint. Pressure should increase when the setpoint is raised and decrease when the setpoint is lowered. Use accurate pressure testing equipm

Summary of the content on the page No. 9

® L91A,B,D PROPORTIONING PRESSURETROL CONTROLLERS Replacing the Controller SERVICE INFORMATION Potentiometer (Fig. 8–10) IMPORTANT: CAUTION 1. Replace the controller potentiometer only when nec- Electrical Shock Hazard essary to obtain proper operation. 1. Only qualified service technicians should attempt to 2. When replacing the potentiometer, be very careful not service or repair flame safeguard controls and to bend or damage the wiper arm, and not to change burner systems. the wiper tens

Summary of the content on the page No. 10

® L91A,B,D PROPORTIONING PRESSURETROL CONTROLLERS REMOVE BRACKET SCREW FROM TOP OF CASE TERMINAL MAIN DIFF. TERMINAL 16 7 BLOCK F 14 BLOCK 6 BRACKET E 12 5 BRACKET MAIN DIFF. 10 D 4 16 7 8 C 3 F 14 6 6 B 2 12 E 4 5 A 1 TERMINAL 10 D 2 4 MIN 8 0 0 R C BLOCK 3 6 kPa B OZS 2 DIFF. IS W 4 2 TERMINAL A IN ADDITIVE 2 1 MIN BLOCK B 0 0 kPa OZS DIFF. IS 2 IN ADDITIVE FIT HOLE IN BOTTOM OF BRACKET OVER SCREW PROTRUDING UPWARD M8521A FROM BOTTOM OF CASE M8548A Fig. 8. Removing terminal block bracket

Summary of the content on the page No. 11

® L91A,B,D PROPORTIONING PRESSURETROL CONTROLLERS 11 60-2152—08

Summary of the content on the page No. 12

® L91A,B,D PROPORTIONING PRESSURETROL CONTROLLERS Automation and Control Solutions Honeywell International Inc. 1985 Douglas Drive North Golden Valley, MN 55422 Honeywell Limited-Honeywell Limitée 35 Dynamic Drive ® U.S. Registered Trademark Toronto, Ontario M1V 4Z9 © 2009 Honeywell International Inc. 60-2152-—08 K.K. Rev. 12-09 customer.honeywell.com Printed in U.S.A.


Alternative user manuals
# User manual Category Download
1 Honeywell VR8204 User manual Boiler 20
2 Honeywell HZ432 User manual Boiler 28
3 Honeywell RESET CONTROLS AQ251 User manual Boiler 8
4 Honeywell L91D User manual Boiler 11
5 Honeywell Local Operator Interface S7999B User manual Boiler 4
6 Honeywell VR8304 User manual Boiler 31
7 Honeywell S9360A User manual Boiler 0
8 Honeywell RVGP User manual Boiler 0
9 Honeywell TRIPLEAQUASTAT L8151A User manual Boiler 7
10 Honeywell S9361A User manual Boiler 3
11 Honeywell S9370A User manual Boiler 0
12 Honeywell Series 4 User manual Boiler 0
13 Honeywell S9371A User manual Boiler 1
14 Honeywell AQUASTATIC L7224 User manual Boiler 0
15 Honeywell L91B User manual Thermostat 1
16 Sony HDV 1080I HVR-M15N/M15P User manual Boiler 67
17 Sony HDV 1080I HVR-M25N/M25P User manual Boiler 50
18 A.O. Smith 200 User manual Boiler 2
19 A.O. Smith 201 User manual Boiler 7
20 A.O. Smith 750 & 1000 User manual Boiler 6