Harman Stove Company SF160 user manual

User manual for the device Harman Stove Company SF160

Device: Harman Stove Company SF160
Category: Boiler
Manufacturer: Harman Stove Company
Size: 2.18 MB
Added : 8/23/2014
Number of pages: 14
Print the manual

Download

How to use this site?

Our goal is to provide you with a quick access to the content of the user manual for Harman Stove Company SF160. Using the online preview, you can quickly view the contents and go to the page where you will find the solution to your problem with Harman Stove Company SF160.

For your convenience

If looking through the Harman Stove Company SF160 user manual directly on this website is not convenient for you, there are two possible solutions:

  • Full Screen Viewing - to easily view the user manual (without downloading it to your computer), you can use full-screen viewing mode. To start viewing the user manual Harman Stove Company SF160 on full screen, use the button Fullscreen.
  • Downloading to your computer - You can also download the user manual Harman Stove Company SF160 to your computer and keep it in your files. However, if you do not want to take up too much of your disk space, you can always download it in the future from ManualsBase.
Harman Stove Company SF160 User manual - Online PDF
Advertisement
« Page 1 of 14 »
Advertisement
Print version

Many people prefer to read the documents not on the screen, but in the printed version. The option to print the manual has also been provided, and you can use it by clicking the link above - Print the manual. You do not have to print the entire manual Harman Stove Company SF160 but the selected pages only. paper.

Summaries

Below you will find previews of the content of the user manuals presented on the following pages to Harman Stove Company SF160. If you want to quickly view the content of pages found on the following pages of the manual, you can use them.

Abstracts of contents
Summary of the content on the page No. 1

Installation & Operating Manual
Trident Boilers: SF160, SF260, SF360
R3
SAFETY NOTICE
PLEASE READ THIS ENTIRE MANUAL BEFORE YOU INSTALL AND/OR USE YOUR NEW BOIL-
ER. FAILURE TO FOLLOW INSTRUCTIONS MAY RESULT IN PROPERTY DAMAGE, BODILY
INJURY, OR EVEN DEATH.
IF THIS HARMAN BOILER IS NOT PROPERLY INSTALLED, A HOUSE FIRE MAY RESULT. FOR
YOUR SAFETY, FOLLOW INSTALLATION DIRECTIONS.
CONTACT LOCAL BUILDING OR FIRE OFFICIALS ABOUT RESTRICTIONS AND INSTALLATION
INSPECTION REQUIREMENTS IN YOUR AREA

Summary of the content on the page No. 2



Summary of the content on the page No. 3

Congratulations, Y ou have just purchased the finest wood / coal boiler available. Harman T rident boilers are constructed of high quality materials and are manufactured by a highly skilled team of assemblymen. Each boiler is inspected and pressure tested for quality assurance. This manual is designed to provide all of the basic information needed for a safe and proper installation. However , there are many skills needed that can not be learned by reading this manual. Harman Stove Comp

Summary of the content on the page No. 4

Packing List The Following items are supplied with your Harman T rident Boiler: Please notify your Harman Dealer if you are missing any items. -- Shaker Handle --Johnson Controls Aquastat - (3) pieces; A350 Controller w/ Sensor wire S350 Stage Module Y350 Power Supply --Immersion W ell --Din Rail and (2) End Clamps --T erminal Box --T erminal Block and (2) #8-32 nuts --Pressure Relief Valve (30 psi.) --T emperature / Pressure Gauge --A

Summary of the content on the page No. 5

Installation Getting Started Pressure Relief Valve DomesticHot Water The sheet metal sides and top are easily Coil Option Temp/Pressure Gauge removed to reduce the chance of dents and/or scratches in the finish. Simply lift the top of f, and that will allow the sides to be pulled away and up, for removal. T o re-install, slide the channel, at the Immersion Well bottom of each side piece, over the lip at the bot- Johnson Controls OptionalElectric tom of the boiler , and hold do

Summary of the content on the page No. 6

Installation Bolt the Automatic Draft Control through Aquastat Installation the 1/2 in. hole in the center of the bottom door . (See optional items, page 7) Lay the din rail Be sure to hold the Draft Control straight while on a flat surface, with the flat side down. Secure tightening. Feed the two wires from the draft mo- one end clamp, on the left side. Slide the A350 tor through the flexible conduit and a 90˚ fitting. controller onto the rail from right to left until it is Secure

Summary of the content on the page No. 7

Installation Wiring and Electrical Optional Items There is a domestic hot water coil available Following the wiring diagram, run all wires for your Trident Boiler. The coil installs in the front to their designated connections. Save the main power for the last hook-up, and leave the breaker of the boiler , and allows your domestic water to be heated by the heating system water . Install the in the of f position. The sensor wires attach to the A350 Controller on the terminals marked “

Summary of the content on the page No. 8

Installation 3 feet (0.9m) above the point at which they exit plumbing from the roof, it must also extend 2 feet (0.6m) The Harman T rident Boiler can be used as above the highest point within a 10 ft. (3m) radius. a “Stand Alone” boiler or as an add-on to an exist- ing hot water heating system. DO NOT CONNECT THIS uNIT TO A CHImNEy The diagrams in this manual are meant to fLuE THAT IS SEr VING ANOTHEr AppLIANCE. show the necessary equipment and piping. Y our system may look very

Summary of the content on the page No. 9

Installation The circulator installed between the two boilers may be hooked up to run continuously during the heating season or , an additional S350 control (not supplied) could be installed to turn it on and of f automatically . This control must be used as a “close on rise of temperature” (jumper in cooling posi- tion). Harman Stove Company recommends that 1-1/4 in. pipe be used between the two boilers. Also recommended is that the first section of pipe of f of the top of the T riden

Summary of the content on the page No. 10

Operation Automatic Draft Control Starting a Wood fire The heat output is regulated by the auto- Make sure the boiler and all piping is full matic draft control on the bottom door . The electric of water and that all air has been purged from the system. motor (A) opens and closes the flapper door (B). Opening and closing the flapper door regulates Never start a fire without water in the the air flow into the firebox. system. An explosion will occur. The maximum air flow can

Summary of the content on the page No. 11

Operation Starting a Coal fire Loading Make sure the boiler and all piping is full Coal should never be added unless there of water and that all air has been purged from the is a reasonably hot fire. The coal bed should be system. bright and vigorous. If you have an active coal bed, full loads can be added at any time. If not, Never start a fire without water in the add new coal in layers, as described in starting a system. An explosion will occur. coal fire. T urn on electrical

Summary of the content on the page No. 12

Operation During the first few hours of burning, a blue Safety Tips When opening the firebox door , it should smoke may be observed rising from the boiler . This is the paint going through the curing process. be cracked, slightly open, for a few seconds to allow air in to burn any gases which may be It is advisable to increase the amount of fresh present. This will also allow smoke to be drawn air in the room during this break in period. This can be achieved by opening doors and w

Summary of the content on the page No. 13

Maintenance maintenance The spiral chamber is basically self-cleaning. However , if there is a draft problem and you have been burning wood for a long time with little demand, the spiral chamber will need to be cleaned. T o clean the spiral chamber , remove the stovepipe and scrape any creosote or debris from the top and front of the chamber . The rear of the chamber should not have much accumulation. If it does, clean it out. NOTE: 1/4” to 1/2” of creosote in the spiral chamber is norma

Summary of the content on the page No. 14

Warranty 1 year Limited Warranty (commercial) 5 year Limited Warranty (residential) W arranty is not transferable. Harman Stove Company warrants its products to be free from defects in material and workmanship, in normal use and service, for five (5) years from the date of purchase. If defective in material or workmanship, and if removed by the owner within 60 months of the date of installation, Harman Stove Company will, at its option, repair or replace the product as described below . T


Alternative user manuals
# User manual Category Download
1 Harman Stove Company PB 105 User manual Boiler 4
2 Harman Stove Company SF360 User manual Boiler 0
3 Harman Stove Company SF260 User manual Boiler 1
4 Sony HDV 1080I HVR-M15N/M15P User manual Boiler 67
5 Sony HDV 1080I HVR-M25N/M25P User manual Boiler 50
6 A.O. Smith 200 User manual Boiler 2
7 A.O. Smith 201 User manual Boiler 7
8 A.O. Smith 750 & 1000 User manual Boiler 6
9 A.O. Smith GB/GW-400 User manual Boiler 10
10 A.O. Smith DB/DW-720-1810 User manual Boiler 1
11 A.O. Smith DB-720 thru 1810 User manual Boiler 0
12 A.O. Smith GB/GW-650 User manual Boiler 3
13 A.O. Smith GB/GW-500 User manual Boiler 5
14 A.O. Smith GB/GW-200 User manual Boiler 2
15 A.O. Smith ACGSS02307 User manual Boiler 0