Crown Boiler CWD220 user manual

User manual for the device Crown Boiler CWD220

Device: Crown Boiler CWD220
Category: Boiler
Manufacturer: Crown Boiler
Size: 2.27 MB
Added : 5/2/2014
Number of pages: 78
Print the manual

Download

How to use this site?

Our goal is to provide you with a quick access to the content of the user manual for Crown Boiler CWD220. Using the online preview, you can quickly view the contents and go to the page where you will find the solution to your problem with Crown Boiler CWD220.

For your convenience

If looking through the Crown Boiler CWD220 user manual directly on this website is not convenient for you, there are two possible solutions:

  • Full Screen Viewing - to easily view the user manual (without downloading it to your computer), you can use full-screen viewing mode. To start viewing the user manual Crown Boiler CWD220 on full screen, use the button Fullscreen.
  • Downloading to your computer - You can also download the user manual Crown Boiler CWD220 to your computer and keep it in your files. However, if you do not want to take up too much of your disk space, you can always download it in the future from ManualsBase.
Crown Boiler CWD220 User manual - Online PDF
Advertisement
« Page 1 of 78 »
Advertisement
Print version

Many people prefer to read the documents not on the screen, but in the printed version. The option to print the manual has also been provided, and you can use it by clicking the link above - Print the manual. You do not have to print the entire manual Crown Boiler CWD220 but the selected pages only. paper.

Summaries

Below you will find previews of the content of the user manuals presented on the following pages to Crown Boiler CWD220. If you want to quickly view the content of pages found on the following pages of the manual, you can use them.

Abstracts of contents
Summary of the content on the page No. 1

CWD Series
Gas-Fired Direct Vent Hot Water Boilers
INSTALLATION INSTRUCTIONS
These instructions must be affi xed on or adjacent to the boiler
Models:
• CWD060
WARNING: Improper installation,
adjustment, alteration, service or
• CWD083
maintenance can cause property
• CWD110
damage, injury, or loss of life. For
assistance or additional information,
• CWD138
consult a qualifi ed installer, service
• CWD165
agency or the gas supplier. Read
these instructions carefully before
• CWD193
i

Summary of the content on the page No. 2

TABLE OF CONTENTS I Product Description 1 II Specifi cations 1 III Before Installing 2 IV Locating the Boiler 2 V Air for Combustion and Ventilation 4 VI Venting 9 Vent System Design 9 Vent System Assembly 22 VII Gas Piping 32 VIII System Piping 33 IX Wiring 38 CB502 Control System 38 R8285 Control system 44 X Start-up and Checkout 48 XI Service and Maintenance 52 XIITroubleshooting 57 XIII Parts 65 Appendix A:Special Requirements for 74 Side-Wall Vented Appliances in the Commonwealth of Massach

Summary of the content on the page No. 3

I Product Description The CWD series boiler is a cast iron gas fi red boiler designed for use in forced hot water heating systems. It is is a low pressure boiler intended for use in closed heating systems with water temperatures under 240F. This boiler may be vented either vertically or horizontally with combustion air supplied from either outdoors or (under certain conditions) indoors. It is ideal for use in installations where a reliable source of clean indoor combustion air cannot be guara

Summary of the content on the page No. 4

III Before Installing 1) Safe, reliable operation of this boiler depends upon installation by a professional heating contractor in strict accordance with this manual and the authority having jurisdiction. • In the absence of an authority having jurisdiction, installation must be in accordance with this manual and the National Fuel Gas Code, ANSI Z223.1. • Where required by the authority having jurisdiction, this installation must conform to the Standard for Controls and Safety Dev

Summary of the content on the page No. 5

FIGURE 2a: CLEARANCES WHEN BOILER IS DIRECT VENTED (OUTDOOR COMBUSTION AIR IS USED) FIGURE 2b: CLEARANCES WHEN COMBUSTION AIR IS OBTAINED FROM BOILER ROOM 3 3

Summary of the content on the page No. 6

TABLE 2: CLEARANCES FROM VENT PIPING TO COMBUSTIBLE CONSTRUCTION MINIMUM CLEARANCE TO COMBUSTIBLE TYPE OF VENT PIPE PIPE DIRECTION ENCLOSURE MATERIAL HEAT FAB SAF-T VENT AT LEAST ONE SIDE OPEN, PROTECH FASNSEAL VERTICAL OR 1” COMBUSTIBLE MATERIAL ON A PROTECH FASNSEAL W2 HORIZONTAL MAXIMUM OF THREE SIDES METAL-FAB CORR/GUARD HEAT FAB SAF-T VENT PROTECH FASNSEAL HORIZONTAL OR VERTICAL 8” ENCLOSED ON ALL FOUR SIDES Z-FLEX Z-VENT III WITH OFFSETS METAL-FAB CORR/GUARD HEAT FAB SAF-T VENT PROTEC

Summary of the content on the page No. 7

Step 2: Determine whether the boiler is to be installed in a confi ned space A confi ned space is defi ned by the National Fuel Gas Code as having a volume less than 50 cubic feet per 1000 BTU/hr input of all appliances installed in that space. To determine whether the boiler room is a confi ned space: 1) Total the input of all appliances in the boiler room in thousands of BTU/hr. Round the result to the next highest 1000 BTU/ hr. 2) Find the volume of the room in cubic feet. The volume of the ro

Summary of the content on the page No. 8

Step 5: If Indoor Combustion Air is Used, Provide Air as Follows: 1) Buildings of other than unusually tight construction: Unconfi ned Space– Natural infi ltration into the boiler room will normally provide adequate air for combustion and ventilation without additional louvers or openings into boiler room. Confi ned Space – Provide two openings into the boiler room, one near the fl oor and one near the ceiling. The top edge of the upper opening must be within 12” of the ceiling and

Summary of the content on the page No. 9

FIGURE 4: ALL AIR FROM OUTSIDE USING VENTILATED CRAWL SPACE AND ATTIC FIGURE 5: ALL AIR FROM OUTSIDE USING VENTILATED ATTIC 7 7

Summary of the content on the page No. 10

FIGURE 6: ALL AIR FROM OUTSIDE USING OPENINGS INTO BOILER ROOM FIGURE 7: ALL AIR FROM OUTSIDE USING HORIZONTAL DUCTS INTO BOILER ROOM 8 8

Summary of the content on the page No. 11

VI Venting WARNING Failure to vent this boiler in accordance with these instructions could result in unreliable boiler operation, severe damage to the boiler or property, or unsafe operation: * Do not attampt to vent this boiler with galvanized, PVC, or any other vent system not listed in Table 4. * Do not attempt to mix components from different approved vent systems. * Do not install a barometric damper or drafthood on this boiler. * Do not attempt to use the vent system for this boiler wit

Summary of the content on the page No. 12

TABLE 3a: SUMMARY OF HORIZONTAL VENTING OPTIONS VENT OPTION # 12345 (RESERVED HORIZONTAL HORIZONTAL CLASSIFICATION USED IN THIS HORIZONTAL HORIZONTAL FOR FUTURE DIRECT DIRECT MANUAL DIRECT VENT DIRECT VENT USE) EXHAUST EXHAUST ILLUSTRATED IN FIGURE 8a OR 8b 8a OR 8b 9 9 VENT PIPE STRUCTURE WALL WALL WALL WALL PENETRATION AIR INTAKE PIPE STRUCTURE WALL WALL N.A. N.A. PENETRATION VENT PIPE SIZE 3” 4” 3” 4” AIR INTAKE PIPE SIZE 4” 4” N.A. N.A. CWD060 - CWD138 55 FT 55 FT 55 FT 55 FT CWD165 35 F

Summary of the content on the page No. 13

FIGURE 8a: HORIZONTAL DIRECT VENTING USING SEPARATE TERMINALS (VENT OPTIONS 1-2) FIGURE 8b: HORIZONTAL DIRECT VENTING USING COAXIAL TERMINAL (VENT OPTIONS 1-2) 11 11

Summary of the content on the page No. 14

FIGURE 9: HORIZONTAL DIRECT EXHAUST VENT SYSTEM (VENT OPTIONS 4,5) 2) Maximum Vent and Air Intake Lengths - The maximum length of the vent air intake piping depends upon the vent option selected, the vent pipe size, and the boiler size. See Table 3 for the maximum vent length. In addition to the maximum length of piping shown in Table 3, the following fi ttings may also be used: • Horizontal Vent Systems: One 90 deg. elbow • Vertical Vent Systems: Two 90 deg. elbows • Vertical Coaxial

Summary of the content on the page No. 15

3) Permitted Terminals for Horizontal Venting (Vent Options 1 - 5) - Table 3a shows permitted types of terminals for both the vent and air inlet systems. On horizontal direct vent systems using 4” air inlet pipe (Vent Options 1 and 2), the following Crown co-axial terminals may be used. These terminals have the advantage of requiring only one wall penetration. Part numbers for the Crown coaxial terminals are as follows: • 3” Vent - 50-003 • 4” Vent - 50-004 When separate ven

Summary of the content on the page No. 16

TABLE 3b: SUMMARY OF VERTICAL VENTING OPTIONS VENT OPTION # 6789 10 (RESERVED VERTICAL VERTICAL CLASSIFICATION USED IN THIS VERTICAL VERTICAL FOR FUTURE DIRECT DIRECT MANUAL DIRECT VENT DIRECT VENT USE) EXHAUST EXHAUST ILLUSTRATED IN FIGURE 10 10 11 11 VENT PIPE STRUCTURE ROOF ROOF ROOF ROOF PENETRATION AIR INTAKE PIPE STRUCTURE ROOF OR WALL ROOF OR WALL N.A. N.A. PENETRATION VENT PIPE SIZE 3” 4” 3” 4” AIR INTAKE PIPE SIZE 4” 4” N.A. N.A. CWD060 - CWD138 47 FT 47 FT 47 FT 47 FT CWD165 27 FT 4

Summary of the content on the page No. 17

FIGURE 10: VERTICAL NON-COAXIAL DIRECT VENT SYSTEM (VENT OPTIONS 6, 7) FIGURE 11: VERTICAL DIRECT EXHAUST SYSTEM (VENT OPTIONS 9, 10) 15 15

Summary of the content on the page No. 18

TABLE 3c : SUMMARY OF VERTICAL COAXIAL VENTING OPTIONS VENT OPTION # 11 12 13 VERTICAL VERTICAL VERTICAL CLASSIFICATION USED IN THIS COAXIAL COAXIAL COAXIAL MANUAL DIRECT VENT DIRECT VENT DIRECT VENT VENT PIPE STRUCTURE ROOF ROOF ROOF PENETRATION AIR INTAKE PIPE STRUCTURE ROOF ROOF ROOF PENETRATION VENT PIPE SIZE 3” 3” 4” AIR INTAKE PIPE SIZE 4” 4” 4” (NON-COAXIAL SECTION) AIR INTAKE PIPE SIZE 5” 5” 7” (COAXIAL SECTION) CWD060 - CWD138 47 FT 47 FT 47 FT CWD165 27 FT 27 FT CWD193 N.R. N.R

Summary of the content on the page No. 19

FIGURE 12: VERTICAL COAXIAL DIRECT VENT USING CROWN #500005 VENT KIT (VENT OPTION 11) FIGURE 13: VERTICAL COAXIAL DIRECT VENT USING HEAT FAB SAF-T VENT SC (VENT OPTIONS 12, 13) 17 17

Summary of the content on the page No. 20

TABLE 4: PERMISSIBLE VENT SYSTEMS AND PRINCIPLE VENT COMPONENTS CONDENSATE WALL HORIZONTAL VERTICAL MANUFACTURER VENT SYSTEM SIZE TRAP THIMBLES TERMINATION TERMINATION 7393GC ELBOW: 7314TERM 9321 3 7393GCS TEE: 7390TEE 5300CI (NOTE 3) SAF-T VENT 5391CI EZ SEAL 7493GC 9421 ELBOW: 7414TERM 4 7493GCS 5400CI (NOTE 3) TEE: 7490TEE 5491CI HEAT FAB ELBOW (NOTE 5): 5300CI + SC03VT SC03DRN SC03FS SC03HT + 7314TERM 3 (NOTE 6) (NOTE 3) SC03FSA TEE (NOTE 5): SC03HT + 7390TEE SAF-T VENT SC ELBOW (NOTE 5):


Alternative user manuals
# User manual Category Download
1 Crown Boiler 24-03 User manual Boiler 0
2 Crown Boiler 24-08 User manual Boiler 0
3 Crown Boiler 24-06 User manual Boiler 0
4 Crown Boiler 24-09 User manual Boiler 0
5 Crown Boiler 24-07 User manual Boiler 0
6 Crown Boiler 24-11 User manual Boiler 0
7 Crown Boiler 24-05 User manual Boiler 0
8 Crown Boiler 24-10 User manual Boiler 0
9 Crown Boiler 32 User manual Boiler 0
10 Crown Boiler 32-475ECS User manual Boiler 0
11 Crown Boiler 24-12 User manual Boiler 0
12 Crown Boiler 32-380ECS User manual Boiler 0
13 Crown Boiler 50-003 User manual Boiler 0
14 Crown Boiler 24-04 User manual Boiler 0
15 Crown Boiler ABF-EID User manual Boiler 0
16 Sony HDV 1080I HVR-M15N/M15P User manual Boiler 67
17 Sony HDV 1080I HVR-M25N/M25P User manual Boiler 50
18 A.O. Smith 200 User manual Boiler 2
19 A.O. Smith 201 User manual Boiler 7
20 A.O. Smith 750 & 1000 User manual Boiler 6