Summary of the content on the page No. 1
Corporate Headquarters
GarrettCom, Inc.
47823 Westinghouse Dr.
Fremont, CA 94539-7437
Phone (510) 438-9071
Fax (510) 438-9072
Magnum 6K32F, 6K32FR, 6K32FC &
Website: http://www.GarrettCom.com
6K32FRC
email support@garrettcom.com
Industrial Managed Switch
Installation and User Guide
Hardware User Manual
www .. GarrettCom com www .. GarrettCom com
Summary of the content on the page No. 2
Magnum 6K32F/FR/FC/FRC Managed Switch Installation and User Guide (05/08) Magnum ™ 6K32F, 6K32FR, 6K32FC & 6K32FRC Managed Switch Hardware Installation and User Guide Part #: 84-00103Z (Rev. A) Trademarks Ethernet is a trademark of Xerox Corporation NEBS is a trademark of Telcordia Technologies UL is a registered trademark of Underwriters Laboratories GarrettCom, Magnum, Personal Switch, S-Ring, Link-Loss-Learn, Converter Switch and Convenient Switch are trademarks and Personal Hub
Summary of the content on the page No. 3
Magnum 6K32F/FR/FC/FRC Managed Switch Installation and User Guide (05/08) Contacting GarrettCom, Inc Please use the mailing address, phone and fax numbers and email address listed below: GarrettCom, Inc. 47823Westinghouse Dr. Fremont, CA 94539-7437 Phone (510) 438-9071 Fax (510) 438-9072 Website: http://www.GarrettCom.com email support@garrettcom.com Federal Communications Commission Radio Frequency Interference Statement This equipment generates, uses and can radiate freque
Summary of the content on the page No. 4
Magnum 6K32F/FR/FC/FRC Managed Switch Installation and User Guide (05/08) TABLE OF CONTENTS.......................................................................... Page 1.0 SPECIFICATIONS................................................................................1 1.1 Technical Specifications.......................................................................1 1.2 Ordering Information ...........................................................................4 2.0 INTRO
Summary of the content on the page No. 5
Magnum 6K32F/FR/FC/FRC Managed Switch Installation and User Guide (05/08) 4.4 Flow-control, IEEE 802.3x standard..................................................46 5.0 6K32F SERIES MANAGED SWITCH PORT MODULES.............47 5.1 Inspecting the Package and Product...................................................47 5.2 6KPM Module Description ................................................................47 5.2.1 6KP6-RJMST multi-mode FX-ST “twist lock” Module ............48 5.2.1a 6KP6
Summary of the content on the page No. 6
Magnum 6K32F/FR/FC/FRC Managed Switch Installation and User Guide (05/08) The Magnum Line INDUSTRIAL NETWORKING PRODUCTS "DESIGNED AND MANUFACTURED IN THE USA" OVERVIEW GarrettCom, Inc. offers the premium-quality Magnum ™ line of INDUSTRIAL connectivity products with industry-standard functionality and built-in fiber configurability. Magnum products are designed for use in demanding Industrial Grade, Carrier Class, POWER UTILITY and OEM applications where reliability is a primary consid
Summary of the content on the page No. 7
Magnum 6K32F/FR/FC/FRC Managed Switch Installation and User Guide (05/08) 1.0 SPECIFICATIONS 1.1 Technical Specifications Performance Filtering / Forwarding Rate: Ethernet:14,880 pps Fast Ethernet: 148,800 pps Gigabit Ethernet: 1,488,000 pps Switching Processing Type: Store and Forward with IEEE 802.3x full- duplex flow -control, non-blocking Data Rate: 10Mbps,100Mbps and 1000Mbps Address Table Capacity: 4K node, self-learning with
Summary of the content on the page No. 8
Magnum 6K32F/FR/FC/FRC Managed Switch Installation and User Guide (05/08) Maximum Standard Gigabit Ethernet Segment Lengths: 1000BASE-T (CAT5E or higher is recommended) - 100 m 1000BASE-SX, full-duplex, multi-mode(62.5 μm cable) - 220m 1000BASE-SX, full-duplex, multi-mode(50 μm cable) - 550m 1000BASE-LX, full-duplex, single-mode(9 μm cable) -5Km Fiber connector types supported: ST-type (twist-lock) SC-type (snap-in) MTRJ-type Small Form Factor (SFF) LC-type S
Summary of the content on the page No. 9
Magnum 6K32F/FR/FC/FRC Managed Switch Installation and User Guide (05/08) Fuse Required – 3 Amps 125VDC and 100VDC Input Voltage : 88 to 300VDC Fuse Required – 1 Amp Std. Terminal Block : “ -, GND, + ” Power Consumption: same as for AC models, see above Warning- All the fuse replacement must be replaced with same value. For (Optional) DC internal power supplies at –48VDC, 24VDC and 125VDC, including Dual Source options (for continuity of operation when either of the DC input sources a
Summary of the content on the page No. 10
Magnum 6K32F/FR/FC/FRC Managed Switch Installation and User Guide (05/08) 1.2 Ordering Information Magnum Managed Switch MODEL DESCRIPTION Magnum 6K32F or 6K32FR (Reverse model) 32-10/100 RJ-45 ports or 8 Gigabit ports managed switch with four modular slots which may be configured with a selection of 10/100/1000Mb fiber and copper connector types, max. 32 ports 10/100 or 8 ports Gigabit max., or combination. Magnum 6K32F-48VDC:Same as 6K32F except power input is –48VDC Magnum 6K32F-
Summary of the content on the page No. 11
Magnum 6K32F/FR/FC/FRC Managed Switch Installation and User Guide (05/08) 6KP8-MTRJ SFF Fiber module, w/eight 100Mb mm FX MT-RJ connectors 6KP8-MLC SFF Fiber module, w/eight 100Mbps mm FX LC connectors 6KP8-SLC SFF Fiber module, w/eight 100Mbps sgl-m FX LC connectors 6KP8-45MT “4+4” module, w/four RJ-45 ports and four 2km mm FX MT-RJ’s 6KP8-45MLC “4+4” module, w/four RJ-45 ports and four 2km mm LC connectors 6KP8-45SLC “4+4” module, w/four RJ-45 ports and four 15km Sm LC connectors 6KP6-M
Summary of the content on the page No. 12
Magnum 6K32F/FR/FC/FRC Managed Switch Installation and User Guide (05/08) GBIC-TP GBIC transceiver module for use in GBPM-xOTX. One 802.3ab 1000BASE-T port with RJ-45 connector Modules with Gb, not using GBICs (all modules include front panel) 6KP5-1CU4RJ “G+4” module, with one GBIC copper (Auto-negotiating) transceiver and four 10/100 RJ-45 connectors 6KP5-1CU4MT “G+4” module, with one GBIC copper (Auto-negotiating) transceiver and four 100Mb MTRJ Fx-Multi-mode connectors 6KP3-1CU2FXT
Summary of the content on the page No. 13
Magnum 6K32F/FR/FC/FRC Managed Switch Installation and User Guide (05/08) 6K32F Series PoE Modules with 48VDC Pass-Through Configuration options: All module slots of 6K32F Series switch with 48VDC power input may be configured with a PoE Module (typical configuration has slot A loaded first with PoE module) P6KP8-RJ45 8 port PoE module for 6Ks with 48vdc PS, w/eight PoE power source 10/100 auto-negotiating auto cross RJ-45 ports. P6KP8-45RJ “4+4” port PoE module for 6Ks with 48vdc PS,
Summary of the content on the page No. 14
Magnum 6K32F/FR/FC/FRC Managed Switch Installation and User Guide (05/08) 6K32F Series PoE Modules with 48VDC Power Inside NOTE: For configuring in 6K Switches having AC /125VDC power input Configuration options: only one A, B, C or D (left to right) module slot of 6K32F Series switch with 48VDC power input may be configured with a PoE Module (typical configuration has slot A loaded with PoE module) 6KAC-PoE-PS Power supply for PoE to 4 ports, 60 watts, mounts inside of a full-width ra
Summary of the content on the page No. 15
Magnum 6K32F/FR/FC/FRC Managed Switch Installation and User Guide (05/08) 2.0 Introduction 2.1 Inspecting the Package and Product Examine the shipping container for obvious damage prior to installing this product; notify the carrier of any damage that you believe occurred during shipment or delivery. Inspect the contents of this package for any signs of damage and ensure that the items listed below are included. This package should contain: 1 Magnum 6K32F, 6K32FR, 6K32FC or 6K32FRC M
Summary of the content on the page No. 16
Magnum 6K32F/FR/FC/FRC Managed Switch Installation and User Guide (05/08) 2.2 Product Description – Magnum 6K32FC / FRC (Convection cooled - No-fans) Managed Switch All of the Magnum 6K32F Series of Ethernet Switches comply with IEC61850 and IEEE1613 Utility Automation and other industry standards. The Magnum 6K32FC/FRC Managed Switches are specially designed with convection cooling thermal design techniques to minimize heat build up providing an efficient, economical, highly reliab
Summary of the content on the page No. 17
Magnum 6K32F/FR/FC/FRC Managed Switch Installation and User Guide (05/08) switching services for both “smooth” streaming and “bursty” data traffic. For redundant LANs it offers S-ring, RS-Ring, Link-Loss-Learn, STP and RSTP. Optional Security features include SNMPv3, SSL/SSH, 802.1X, TACACS+, Port Security, and Tagged VLANs as well as a secure, user friendly web based option. IGMP Snooping and IGMP-L2 features provide most IGMP Layer 3 functions for multicast traffic with Magnum 6K-Switc
Summary of the content on the page No. 18
Magnum 6K32F/FR/FC/FRC Managed Switch Installation and User Guide (05/08) AC, and –48VDC power input options are designed for Telco environments, while the 24VDC is designed for Industrial/Control Room applications. The 125 & 250VDC versions are for power sub stations applications. Designed primarily for use in harsh, un-controlled temperature industrial applications, the Magnum 6K32FC / FRC provides secure, high performance plug-and- play hardware operation, 802.1p packet prioritization in
Summary of the content on the page No. 19
Magnum 6K32F/FR/FC/FRC Managed Switch Installation and User Guide (05/08) designed to meet the future demand of Ethernet requirements with cost-effective secure solutions. The Magnum 6K32F is also available in a Reverse model option, where the LEDs are on the front and the available ports along with the power supply area found on the rear side. This configuration is mostly used for the carrier-class market. The modules which may be configured and used in the modular slots of the Magnum 6K
Summary of the content on the page No. 20
Magnum 6K32F/FR/FC/FRC Managed Switch Installation and User Guide (05/08) when ON (half-duplex when OFF), and the blinking ACT LED indicates receiving Activity on the port. A fiber cable must be connected into a SFF port and the Link (LK) indicator for that port must be ON (indicating there is a powered-up device at the other end of the cable) in order for a LK LED to provide valid indications of operating conditions on that port. 2.2.3 Eight-Port Copper Module, 6KP8-RJ45 (MDIX)