Summary of the content on the page No. 1
WebShare RB300
Wireless N Broadband Router
A02-RB-W300N
USER GUIDE
A02-RB-W300N _ME01
Where solutions begin
ISO 9001:2000 Company certified
Summary of the content on the page No. 2
WebShare RB300 INDEX CHAPTER 1: INTRODUCTION 1 1.1 An Overview of the WebShare RB300 1 1.2 Package Contents 1 1.3 Technical Features 2 1.4 System Requirements 2 1.5 Setup 2 CHAPTER 2: USING WIRELESS BROADBAND ROUTER 3 2.1 Cautions for using the Wireless Broadband Router 3 2.2 The Front LEDs 4 2.3 The Rear Ports 5 2.4 Cabling 5 CHAPTER 3: CONFIGURATION 7 3.1 Before Configuration 7 3.1.1 Windows 95/98/ME 8 3.1.2 W
Summary of the content on the page No. 3
WebShare RB300 3.7.1 Filter 43 3.7.2 Virtual Server 48 3.7.3 Special AP 51 3.7.4 DMZ 53 3.7.5 Firewall Settings 54 3.8 System 55 3.8.1 Password 55 3.8.2 Time 56 3.8.3 Device Information 57 3.8.4 Log 59 3.8.5 Log Settings 60 3.8.6 Statistics 62 3.8.7 Restart 62 3.8.8 Firmware 63 3.8.9 Configuration 64 3.8.10 UPnP 65 3.8.11 Ping Test 66 3.8.12 Remote Management 67 APPENDIX A: TROUBLESHOOTING 68 A.1 LEDs 68 A.1.1 L
Summary of the content on the page No. 4
WebShare RB300 Copyright Statement No part of this publication may be reproduced, stored in a retrieval system, or transmitted in any form or by any means, whether electronic, mechanical, photocopying, recording or otherwise without the prior writing of the publisher. Windows™ 98SE/2000/ME/XP are trademarks of Microsoft® Corp. Pentium is trademark of Intel. All copyright reserved. The Atlantis Land logo is a registered trademar
Summary of the content on the page No. 5
WebShare RB300 CE Mark Warning This is a Class B product. In a domestic environment, this product may cause radio interference, in which case the user may be required to take adequate measures. CE in which Countries where the product may be used freely: Germany, UK, Italy, Spain, Belgium, Netherlands, Portugal, Greece, Ireland, Denmark, Luxembourg, Austria, Finland, Sweden, Norway and Iceland. France: except the channel 10 thr
Summary of the content on the page No. 6
WebShare RB300 CHAPTER 1: Introduction Congratulations on your purchase of Atlantis Land Wireless Broadband Router. This integrated access device combines Internet gateway functions with wireless LAN and Fast Ethernet switch. It provides a complete solution for Internet surfing and office resources sharing, and it is easy to configure and operate for every users. This manual discusses how to install the Webshare RB300. 1.1 An
Summary of the content on the page No. 7
WebShare RB300 1.3 Technical Features WebShare RB300 provides the following features: Compliant with 802.11n (draft), IEEE 802.11g and 802.11b Devices Built-in 4 x 10/100Mbps Auto-MDIX LAN Ports Built-in 1 x 10/100Mbps Auto-MDIX WAN Port (Internet) Supports Cable/DSL Modems with Dynamic IP, Static IP, PPPoE, L2TP, PPTP or BigPond Connection Types DHCP Server Feature Allocates up to 253 Client IP Addresses Sup
Summary of the content on the page No. 8
WebShare RB300 Make sure that there is proper heat dissipation from and adequate ventilation around the Broadband Router. Do not place heavy objects on the Broadband Router. Fix the direction of the antennas. Try to place the Wireless Router in a position that can best cover your wireless network. Normally, the higher you place the antenna, the better the performance will be. The antenna’s position enhances the receivingsens
Summary of the content on the page No. 9
WebShare RB300 2.2 The Front LEDs LED MEANING This indicator lights green when the hub is receives power, POWER otherwise it is off. This indicator blinks green means the Internet Broadband Router is working successful. Otherwise, this indicator always STATUS on or off means the function of the Internet Broadband Router is fail. The indicators light green when the WAN port was connected to an xDSL/Cable modem success
Summary of the content on the page No. 10
WebShare RB300 2.3 The Rear Ports PORT USAGE POWER JACK Plug the power adapter to this power jack In the four port broadband router, there is an RJ-45 WAN 10/100Mbps Auto-MDIX port for the WAN that will fit the xDSL/Cable modem’s specification need. Four RJ-45 10/100Mbps Auto-MDIX ports for LAN connecting to either 10Mbps or 100Mbps Ethernet connections. There are one 2 dBi Gain Antenna in the rear panel for REVERS
Summary of the content on the page No. 11
WebShare RB300 Plug in the other end of the network cable to the Ethernet port of the xDSL or Cable modem (E.G A02-RA141 or A02-RA111). Use another network cable to connect to the Ethernet card on the computer system; the other end of the cable connects to the LAN port of the Internet Broadband Router. Since the Wireless Broadband Router has four ports, you can connect up to four computers directly to the unit. There you do not
Summary of the content on the page No. 12
WebShare RB300 CHAPTER 3: Configuration The Wireless Broadband Router has a Web GUI interface for the configuration. The device can be configured through the Web Browser. A network manager can manage, control and monitor the Router from the local LAN. This section indicates how to configure the AP to enable its functions. 3.1 Before Configuration This section describes the configuration required by LAN-attached PCs that commun
Summary of the content on the page No. 13
WebShare RB300 3.1.1 Windows 95/98/ME 1. Go to Start / Settings / Control Panel. In the Control Panel, double-click on Network and choose the Configuration tab. 2. Select TCP / IP -> NE2000 Compatible, or the name of any Network Interface Card (NIC) in your PC. 3. Click Properties. 4. Select the IP Address tab. In this page, click the Obtain an IP address automatically radio button.
Summary of the content on the page No. 14
WebShare RB300 3.1.2 Windows NT4.0 1. Go to Start / Settings / Control Panel. In the Control Panel, double- click on Network and choose the Protocols tab. 2. Select TCP/IP Protocol and click Properties. 3. Select the Obtain an IP address from a DHCP server radio button and click OK. Pag. 9
Summary of the content on the page No. 15
WebShare RB300 3.1.3 Windows 2000 1. Go to Start / Settings / Control Panel. In the Control Panel, double-click on Network and Dial-up Connections. 2. Double-click LAN Area Connection. 3. In the LAN Area Connection Status window, click Properties. 4. Select the Obtain an IP address automatically and the Obtain DNS server address automatically radio buttons.). 5. Click OK to finish the configuration.
Summary of the content on the page No. 16
WebShare RB300 3.1.4 Windows XP 1. Go to Start / Control Panel (in Classic View). In the Control Panel, double- click on Network Connections. 2. Double-click Local Area Connection 3. In the LAN Area Connection Status window, click Properties. 4. Select Internet Protocol (TCP/IP) and click Properties. 5. Select the Obtain an IP address automatically and the Obtain DNS server address automatically radio buttons 6.
Summary of the content on the page No. 17
WebShare RB300 3.2 Factory Default Settings Before configuring the Wireless Broadband Router through WLAN, make sure that the SSID, Channel and the WEP was set properly. The default setting of the Wireless Broadband Router that you will use: User: admin Password: admin IP Address: 192.168.1.1 Subnet Mask: 255.255.255.0 DHCP Server: enable (192.168.1.100-192.168.1.199) Wep Encryption: disable SSSID: N Rout
Summary of the content on the page No. 18
WebShare RB300 3.3 Accessing the Wireless Broadband Router Web Configurator Before you configure this device, note that when the Wireless Broadband Router is configured through an Ethernet connection, make sure the manager PC must be set on same the IP network. Open Internet Explorer 5.0 or above Web browser. Enter IP address http://192.168.1.1 (the factory-default IP address setting) to the address location. When the
Summary of the content on the page No. 19
WebShare RB300 3.3.1 Setup Wizard Setup wizard is provided as the part of the web configuration utility. User can simply follow the step-by-step process to get the wireless router configuration ready to run in 6 easy steps by clicking on the “Wizard” button on the function menu. The following screen will appear. Please click Next to continue. Pag. 14
Summary of the content on the page No. 20
WebShare RB300 Step 1: Setup New Password User can change the password and then click Next to continue. Please click Next to continue. Pag. 15