Summary of the content on the page No. 1
M Mo od de ell:: E ES S1 1A AE E
Mini Ethernet to
Mini Ethernet to
R RS S--2 23 32 2 C Co on nv ve er rt te er r
Manual Documentation Number: ES1AE-2907m pn7041-rev002
B&B Electronics Mfg Co Inc – 707 Dayton Rd - PO Box 1040 - Ottawa IL 61350 - Ph 815-433-5100 - Fax 815-433-5104 – www.bb-elec.com
B&B Electronics Ltd – Westlink Commercial Park – Oranmore, Galway, Ireland – Ph +353 91-792444 – Fax +353 91-792445 – www.bb-europe.com
Summary of the content on the page No. 2
Manual Documentation Number: ES1AE-2907m pn7041-rev002 B&B Electronics Mfg Co Inc – 707 Dayton Rd - PO Box 1040 - Ottawa IL 61350 - Ph 815-433-5100 - Fax 815-433-5104 – www.bb-elec.com B&B Electronics Ltd – Westlink Commercial Park – Oranmore, Galway, Ireland – Ph +353 91-792444 – Fax +353 91-792445 – www.bb-europe.com
Summary of the content on the page No. 3
International Headquarters B&B Electronics Mfg. Co. Inc. 707 Dayton Road Ottawa, IL 61350 USA Phone (815) 433-5100 -- General Fax (815) 433-5105 Website: www.bb-elec.com Sales e-mail: orders@bb-elec.com -- Fax (815) 433-5109 Technical Support e-mail: support@bb.elec.com -- Fax (815) 433-5104 European Headquarters B&B Electronics Ltd. Westlink Commercial Park Oranmore, Co. Galway, Ireland Phone +353 91-792444 -- Fax +353 91-792445 Website: www.bb-europe.com
Summary of the content on the page No. 4
Summary of the content on the page No. 5
© 2005 B&B Electronics. No part of this publication may be reproduced or transmitted in any form or by any means, electronic or mechanical, including photography, recording, or any information storage and retrieval system without written consent. Information in this manual is subject to change without notice, and does not represent a commitment on the part of B&B Electronics. B&B Electronics shall not be liable for incidental or consequential damages
Summary of the content on the page No. 6
Summary of the content on the page No. 7
Table of Contents Table of Contents CHAPTER 1: INTRODUCTION..............................................................................1 FEATURES...................................................................................................................1 COMMUNICATION MODES ..........................................................................................2 Direct IP .......................................................................................................
Summary of the content on the page No. 8
LOGGING IN..............................................................................................................13 LOGGING OUT ..........................................................................................................13 USING TUTORIAL AND HELP.....................................................................................14 CONFIGURING NETWORK SETTINGS .........................................................................14 IP Settings.......................
Summary of the content on the page No. 9
Adding a Virtual COM Port using RealPort....................................................... 34 Removing a Virtual COM Port using RealPort .................................................. 34 Updating RealPort.............................................................................................. 35 APPENDIX A: DEFAULT CONFIGURATION SETTINGS ...............................37 APPENDIX B: PRODUCT SPECIFICATIONS ...................................................39 APPENDIX C: D
Summary of the content on the page No. 10
Manual Documentation Number: ES1AE-2907m pn7041-rev002 B&B Electronics Mfg Co Inc – 707 Dayton Rd - PO Box 1040 - Ottawa IL 61350 - Ph 815-433-5100 - Fax 815-433-5104 – www.bb-elec.com B&B Electronics Ltd – Westlink Commercial Park – Oranmore, Galway, Ireland – Ph +353 91-792444 – Fax +353 91-792445 – www.bb-europe.com
Summary of the content on the page No. 11
Introduction Chapter 1: Introduction Chapter 1: Introduction ES1A Mini Ethernet to RS-232 Converters provide simple and cost- effective solutions for connecting RS-232 devices to Ethernet networks. ES1A converters make it easy to connect serial printers, copiers, building automation, retail, point-of-sale, warehousing and banking equipment directly into Ethernet networks. ES1A converters support virtual COM port, console management, TCP and UDP socket, serial bridge, modem emulation
Summary of the content on the page No. 12
Introduction Communication Modes ES1A Ethernet to RS-232 converters allow you to connect serial devices over a LAN or WAN. Serial devices no longer are limited to a physical connection to the PC COM port. They can be installed anywhere on the LAN using TCP/IP or UDP/IP communications. This allows traditional Windows PC software access to serial devices anywhere on the LAN/WAN network. Direct IP Direct IP Mode allows applications using TCP/IP or UDP/IP socket programs to communicate wit
Summary of the content on the page No. 13
Introduction Other Communications Modes ES1A Converters also feature the following communications profiles: Modem Emulation Mode allows you to configure the serial port to operate as if it is a modem. For legacy applications where a serial device is set up to communicate through a modem, the serial device can now be connected to the ES1A and communication occurs over the network. The ES1A emulates modem responses to and from the serial device. In Console Management Mode the ES1A can be
Summary of the content on the page No. 14
Introduction 4 Manual Documentation Number: ES1A -2907m pn7041-rev002 B&B Electronics Mfg Co Inc – 707 Dayton Rd - PO Box 1040 - Ottawa IL 61350 - Ph 815-433-5100 - Fax 815-433-5104 – www.bb-elec.com B&B Electronics Ltd – Westlink Commercial Park – Oranmore, Galway, Ireland – Ph +353 91-792444 – Fax +353 91-792445 – www.bb-europe.com
Summary of the content on the page No. 15
Hardware Overview Chapter 2: Hardware Overview Chapter 2: Hardware Overview Package Checklist ES1A Ethernet to RS-232 Converters are shipped with the following items included: The ES1A module A printed version of this user manual A printed version of the ES1A Quick Start Guide CD-ROM disc with o B&B discovery software o RealPort drivers for Windows 98/ME/2001/XP/NT 4.0/Vista o this user manual in PDF format o a Quick Start guide in PDF format Figure 2. Top View of the ES
Summary of the content on the page No. 16
Hardware Overview Indicators, Switches and Connectors Link Integrity LED (Yellow) When the yellow LED located on the Ethernet jack is illuminated it indicates that a connection (link integrity) has been established between the converter and a node on the network. Network Activity LED When the green LED located on the Ethernet jack is flashing it indicates that data is being sent across the network. Figure 3. LED Indicators on the ES1A Reset Switch The Reset switch is a recessed sw
Summary of the content on the page No. 17
Hardware Overview Serial Port Connector The Serial Port Connector is a DB-9 male connector (configured as a DTE) supporting RS-232 serial communications including TD, RD, TRS, CTS, DTR, DCD, DSR and GND signal lines. Use a standard serial cable if connecting to a DCE; use a null modem (crossover) cable if connecting to a DTE. Refer to Appendices D, and E for connection pin-outs. Power Connector Power is supplied to the ES1A by a 5VDC 1200ma power supply. The power connector is a 5.
Summary of the content on the page No. 18
Hardware Overview 8 Manual Documentation Number: ES1A -2907m pn7041-rev002 B&B Electronics Mfg Co Inc – 707 Dayton Rd - PO Box 1040 - Ottawa IL 61350 - Ph 815-433-5100 - Fax 815-433-5104 – www.bb-elec.com B&B Electronics Ltd – Westlink Commercial Park – Oranmore, Galway, Ireland – Ph +353 91-792444 – Fax +353 91-792445 – www.bb-europe.com
Summary of the content on the page No. 19
Getting Started Chapter 3: Getting Started Chapter 3: Getting Started 1. Check the contents of your ES1A package. It should contain… The ES1A module A printed version of this user manual A printed version of the ES1A Quick Start Guide CD-ROM disc with discovery software, RealPort software, this manual, Quick Start guide 2. Set up the Hardware Connect your PC to the network Connect the ES1A serial port to your serial device (Use a serial cable if it is DCE, null modem cable
Summary of the content on the page No. 20
Getting Started 6. Configure the ES1A In the Configuration, Serial Ports page select the Port Profile you require for use with your application (E.g. RealPort for virtual COM port, TCP Server, UDP server, Serial Bridge, etc) Configure the serial port settings for the selected Port Profile (E.g. In TCP Sockets select client or server, TCP port numbers, etc.) Also configure baud rate, data bits, etc in Basic Serial Settings. Configure any required alarms and notification If RealPort p