Agilent Technologies 8753ES user manual

User manual for the device Agilent Technologies 8753ES

Device: Agilent Technologies 8753ES
Category: Network Router
Manufacturer: Agilent Technologies
Size: 3.53 MB
Added : 4/30/2014
Number of pages: 28
Print the manual

Download

How to use this site?

Our goal is to provide you with a quick access to the content of the user manual for Agilent Technologies 8753ES. Using the online preview, you can quickly view the contents and go to the page where you will find the solution to your problem with Agilent Technologies 8753ES.

For your convenience

If looking through the Agilent Technologies 8753ES user manual directly on this website is not convenient for you, there are two possible solutions:

  • Full Screen Viewing - to easily view the user manual (without downloading it to your computer), you can use full-screen viewing mode. To start viewing the user manual Agilent Technologies 8753ES on full screen, use the button Fullscreen.
  • Downloading to your computer - You can also download the user manual Agilent Technologies 8753ES to your computer and keep it in your files. However, if you do not want to take up too much of your disk space, you can always download it in the future from ManualsBase.
Agilent Technologies 8753ES User manual - Online PDF
Advertisement
« Page 1 of 28 »
Advertisement
Print version

Many people prefer to read the documents not on the screen, but in the printed version. The option to print the manual has also been provided, and you can use it by clicking the link above - Print the manual. You do not have to print the entire manual Agilent Technologies 8753ES but the selected pages only. paper.

Summaries

Below you will find previews of the content of the user manuals presented on the following pages to Agilent Technologies 8753ES. If you want to quickly view the content of pages found on the following pages of the manual, you can use them.

Abstracts of contents
Summary of the content on the page No. 1

Agilent 8753ET/ES
8753ET and 8753ES Network
Analyzers, 30 kHz to 3 or 6 GHz
Data Sheet
For more information about these analyzers,
This document describes the performance
please see the following documents:
and features of the following products:
Pub. Number
• Agilent 8753ES S-parameter vector network
Agilent 8753ET and 8753ES 5968-5159E
analyzer
Network Analyzers
• Agilent 8753ES Option 011 vector network
Overview
analyzer without test set
• Agilent 8753ET Transmission/reflection vector
Agi

Summary of the content on the page No. 2

Table of Contents 3 Definitions and Test Conditions 4 System Performance Summaries 10 Specifications and Characteristics 21 Measurement Throughput Summary 21 Options 22 Test Set Specifications for Option 011 24 Accessories

Summary of the content on the page No. 3

Definitions and Test Conditions Specifications describe the instrument’s warranted Measurement Uncertainty performance after a half-hour warm-up and over Measurement uncertainty curves utilize a Root the temperature range of 25° ± 5° C, unless other- Sum Square (RSS) model for the contribution of wise stated. Specifications for frequencies above random errors such as noise, typical connector 3 GHz do not apply to instruments with Option 075 repeatabilities, and test set switching; this is (75-

Summary of the content on the page No. 4

System Performance Summaries Agilent 8753ES (50-ohm systems) Measurement Port Characteristics 7-mm test ports Frequency Range Corrected 30 kHz– 300 kHz– 1.3 GHz– 3 GHz– Configuration 2 300 kHz 1.3 GHz 3 GHz 6 GHz Network analyzer 8753ES Standard and Option 006 Directivity 55 dB 55 dB 51 dB 46 dB Calibration kit 85031B Source match 55 dB 51 dB 49 dB 43 dB Test-port cables 11857D Load match 55 dB 55 dB 51 dB 46 dB Reflection ±(0.001 dB ±(0.001 dB ±(0.005 dB ±(0.020 dB System dynamic range t

Summary of the content on the page No. 5

Agilent 8753ES (50-ohm systems) Measurement Port Characteristics Type-N test ports Frequency Range Configuration Corrected 30 kHz– 300 kHz– 1.3 GHz– 3 GHz– Network analyzer 8753ES 2 300 kHz 1.3 GHz 3 GHz 6 GHz Standard and Option 006 Directivity 50 dB 50 dB 47 dB 40 dB Calibration kit 85032B Test-port cables 11857D Source match 49 dB 42 dB 36 dB 31 dB System dynamic range Load match 50 dB 50 dB 47 dB 40 dB 1 30 kHz to 50 kHz 70 dB 1 Reflection ±(0.005 dB ±(0.009 dB ±(0.019 dB ±(0.070 dB 50

Summary of the content on the page No. 6

System Performance Summaries Agilent 8753ES (50-ohm systems) Measurement Port Characteristics 3.5-mm test ports Frequency Range Configuration Corrected 30 kHz– 300 kHz– 1.3 GHz– 3 GHz– Network analyzer 8753ES 2 300 kHz 1.3 GHz 3 GHz 6 GHz Standard and Option 006 Directivity 49 dB 46 dB 44 dB 38 dB Calibration kit 85033D Test-port cables 11857D Source match 49 dB 44 dB 41 dB 37 dB System dynamic range Load match 49 dB 46 dB 44 dB 38 dB 1 30 kHz to 50 kHz 70 dB 1 Reflection ±(0.010 dB ±(0.005

Summary of the content on the page No. 7

Agilent 8753ES (75-Ohm Systems) Measurement Port Characteristics Type-N test ports Frequency Range 2 Corrected 30 kHz–300 kHz 300 kHz–1.3 GHz 1.3 GHz–3 GHz Configuration Directivity 48 dB 48 dB 43 dB Network analyzer 8753ES Option 075 Calibration kit 85036B Source match 47 dB 41 dB 35 dB Test-port cables 11857B Load match 48 dB 48 dB 43 dB Reflection ±(0.004 dB ±(0.010 dB ±(0.019 dB System Dynamic Range tracking +0.02 dB/°C) +0.01 dB/°C) +0.02 dB/°C) 1 30 kHz to 50 kHz 68 dB Transmission ±(

Summary of the content on the page No. 8

System Performance Summaries Agilent 8753ES (75-ohm systems) Measurement Port Characteristics Type-F test ports Data is shown for a Type-F female reflection port and a Type-F male transmission port. Configuration Network analyzer 8753E Option 075 Frequency Range Calibration kit 85039B Test-port cables 11857B 2 Corrected 30 kHz–300 kHz 300 kHz–1.3 GHz 1.3 GHz–3 GHz System dynamic range Directivity 45 dB 45 dB 40 dB 1 30 kHz to 50 kHz 68 dB Source match 40 dB 40 dB 30 dB 1 50 kHz to 300 kHz 9

Summary of the content on the page No. 9

Measurement Port Characteristics (continued) Agilent 8753ET (50-ohm systems) Type-N test ports Corrected Reflection Configuration 1 measurements 300 kHz–1.3 GHz 1.3 GHz–3.0 GHz 3.0 GHz–6.0 GHz Network analyzer 8753ET Standard, Option 006, or Option 004 Directivity 50 dB 47 dB 40 dB Calibration kit 85032B Source match 42 dB 36 dB 31 dB Test port cable Part number 8120-4781 Load match System dynamic range One-port cal 24 dB 19 dB 16 dB Enhanced- 24 dB 19 dB 16 dB 300 kHz to 16 MHz 100 dB reflec

Summary of the content on the page No. 10

Agilent 8753ES Specifications 7 Test-Port Output Characteristics Test-Port Input Characteristics Frequency characteristics Frequency range 30 kHz to 3 GHz Range 30 kHz to 3 GHz Option 006 30 kHz to 6 GHz 2,8 Option 006 30 kHz to 6 GHz Average noise level Resolution 1 Hz <3 GHz <-82 dBm (3 kHz BW) 9 Stability ±7.5 ppm (0° to 55° C) <3 GHz <-102 dBm (10 Hz BW) ±3 ppm/year <3 GHz <-110 dBm (10 Hz BW) typical Option 1D5 ±0.05 ppm (0° to 55° C), 3 to 6 GHz <-77 dBm (3 kHz BW) ±0.5 ppm/year 3 to 6

Summary of the content on the page No. 11

1 External source mode (CW time sweep only) Reference level Frequency range 300 kHz to 6 GHz Range ±500 dB R-channel input requirements (typical) Resolution 0.001 dB 2 Power level 0 to -25 dBm Stability Spectral purity 30 kHz to 3 GHz 0.02 dB/° C Maximum <-30 dBc 3 GHz to 6 GHz 0.04 dB/° C spurious input Residual FM <20 kHz Phase Characteristics Typical settling time 500 ms (automatic) Dynamic accuracy (10 Hz IF BW) 50 ms (manual) Range ±180° Frequency readout accuracy 0.1% (automatic) 2

Summary of the content on the page No. 12

Agilent 8753ES Option 011 Specifications Test Port Output Characteristics Test Port Input Characteristics Option 011 Frequency characteristics Frequency range 300 kHz to 3 GHz Range 300 kHz to 3 GHz Option 006 30 kHz to 6 GHz 2 Option 006 30 kHz to 6 GHz Average noise level Resolution 1 Hz 50 kHz to 3 GHz <-90 dBm (3 kHz BW) Stability typically ±7.5 ppm 0° to 55° C 50 kHz to 3 GHz <-110 dBm (10 Hz BW) typically ±3 ppm/year 50 kHz to 3 GHz <-120 dBm (10 Hz BW) typical Option 1D5 typically ±0

Summary of the content on the page No. 13

3 Frequency offset mode Reference level Frequency range 300 kHz to 3 GHz Range ±500 dB Option 006 300 kHz to 6 GHz Resolution 0.001 dB 2 R-channel input requirements Stability Power level 30 kHz to 3 GHz 0.02 dB/° C 300 kHz to 3 GHz 0 to -35 dBm 3 GHz to 6 GHz 0.04 dB/° C 3 GHz to 6 GHz 0 to -30 dBm Range ±180° LO spectral purity Display resolution 0.01°/division 5 Maximum spurious input <-25 dBc Marker resolution 0.01° 2 Residual FM <20 kHz Trace noise LO frequency accuracy ±1 MHz at nom

Summary of the content on the page No. 14

Agilent 8753ET Specifications Test-Port Output Characteristics Test Port Input Characteristics Frequency characteristics Frequency range 300 kHz to 3 GHz Range 300 kHz to 3 GHz Option 006 300 kHz to 6 GHz Option 006 300 kHz to 6 GHz Average noise level Resolution 1 Hz 300 kHz to 3 GHz <-90 dBm (3 kHz BW) 4 Stability ±7.5 ppm (0° to 55° C) 300 kHz to 3 GHz <-110 dBm (10 Hz BW) ±3 ppm/year 300 kHz to 3 GHz <-120 dBm (10 Hz BW) Option 1D5 ±0.05 ppm (0° to 55° C) typical ±0.5 ppm/year 3 GHz to

Summary of the content on the page No. 15

1 External source mode (CW time sweep only) Reference level Frequency range 300 kHz to 6 GHz Range ±500 dB 2 R-channel input requirements Resolution 0.001 dB Power level 0 to -25 dBm Spectral purity Maximum spurious input <-30 dBc Residual FM <20 kHz Typical settling time 500 ms (automatic) 50 ms (manual) 2 Frequency readout accuracy 0.1% (automatic) 2 Input frequency accuracy requirement Manual -0.5 to 5 MHz Accuracy (See magnitude and phase characteristics) Magnitude characteristics

Summary of the content on the page No. 16

Agilent 8753ET/ES Supplemental Characteristics Accuracy Measurement The following graph shows group-delay accuracy Number of display channels at 1.3 GHz with type-N full two-port calibration Four display channels available. and 10-Hz IF bandwidth. Insertion loss is assumed to be <2 dB and electrical length to be ten meters. Number of measurement channels Two primary and two auxiliary measurement channels available. Measurement parameters 8753ET: Reflection, transmission, A, B, R, A/R, B/R, A/

Summary of the content on the page No. 17

Especially suitable for calibrating non- Sweep trigger coaxial environments, such as in test fixtures. Set to either continuous, single, group sweep, or TRL*/LRM* is a special implementation of external trigger. Set external trigger to take a com- TRL/LRM calibration, modified for the three- plete sweep or to measure individual points in a sampler receiver in the 8753ES. Available frequency, power or list sweep. on Agilent 8753ES analyzers. Power Interpolated error correction Set source power

Summary of the content on the page No. 18

Agilent 8753ET/ES Supplemental Characteristics (continued) Disk drive Trace Functions Data, instrument states, user graphics, data plots Display data and test sequences can be stored on internal floppy Display current measurement data, memory data, disk in MS-DOS® or Agilent’s standard LIF formats. or current measurement with measurement and memory data simultaneously. Data Hardcopy Data plotting Trace math Hardcopy plots are automatically produced with Vector division or subtraction of curre

Summary of the content on the page No. 19

Frequency offset on/off • Bandpass impulse Sets the RF source to be swept at a fixed offset The bandpass impulse stimulates a pulsed RF frequency above the receiver as required in a swept signal (with an impulse envelope) and is used RF/IF, fixed LO, mixer test. to measure the time-domain response of band- limited devices. Service menu Select the desired service test, service diagnostic, Windows service or verification mode. The windowing function can be used to modify (filter) the frequency

Summary of the content on the page No. 20

General Characteristics Test sequence output (TEST SEQ) Front Panel Connectors By default, this connector outputs a TTL end-of- 8753ES test ports (without Option 011) sweep signal. It can also be programmed by the Connector type 7 mm, precision user in a test sequence to output a user-defined Impedance 50 ohms (nominal) TTL signal. BNC (f) connector. 8753ES Option 011 test ports Limit test output (LIMIT TEST) Connector type Type-N female This connector outputs a TTL signal of the limit Impe


Alternative user manuals
# User manual Category Download
1 Agilent Technologies Agilent E1345A User manual Network Router 2
2 Agilent Technologies 22ES User manual Network Router 0
3 Agilent Technologies 42030A User manual Network Router 2
4 Agilent Technologies 8753C1 User manual Network Router 0
5 Agilent Technologies 8753ET User manual Network Router 10
6 Agilent Technologies 20ET User manual Network Router 0
7 Agilent Technologies 8714 User manual Network Router 1
8 Agilent Technologies 35670A User manual Network Router 7
9 Agilent Technologies 90015 User manual Network Router 0
10 Agilent Technologies E4400-60230 User manual Network Router 3
11 Agilent Technologies E5805A User manual Network Router 0
12 Agilent Technologies LXI User manual Network Router 0
13 Agilent Technologies E6701A User manual Network Router 1
14 Agilent Technologies N9360A User manual Network Router 1
15 Agilent Technologies J3919A User manual Network Router 0
16 Sony BKS-R3202/R3210/R3220 User manual Network Router 77
17 Sony DVS-V3232B/V3232M User manual Network Router 3
18 Sony BVS-V3232 User manual Network Router 8
19 Sony DMX-WL1 User manual Network Router 6
20 Sony BVS-A3232 User manual Network Router 6