Summary of the content on the page No. 1
AdderView CATxIP 000
User Guide
LOC REM VNC 100 LNK PWR
www.adder.com
Summary of the content on the page No. 2
Contents Introduction Configuration AdderView CATxIP 1000 features - front and rear ....................5 Overall initial configuration ....................................................19 What’s in the box.........................................................................6 Initial configuration ..................................................................20 What you may additionally need ...............................................6 Main menu ...................................
Summary of the content on the page No. 3
HT Operation Further information The front panel indicators ........................................................33 Getting assistance ......................................................................50 Accessing the AdderView CATxIP 1000 ....................................33 Troubleshooting ........................................................................50 Local user access ........................................................................34 Appendix 1 – Local setup menus
Summary of the content on the page No. 4
HT Appendix 3 - VNC viewer connection options .........................72 Appendix 7 – Cable and connector specifications ...................83 Colour/Encoding ...................................................................72 AdderView CATxIP 1000 to power switch cable ................83 Inputs .....................................................................................73 Power switch to power switch daisy chain cable ................83 Misc ........................................
Summary of the content on the page No. 5
Introduction Thank.you.for.choosing.the.AdderView.CATxIP.1000. The.AdderView.CATxIP.1000.is.available.in.two.sizes,. In.addition.to.the.local.user.console,.the.AdderView. from.Adder.Technology..This.compact.unit.has.been. supporting.eight.or.sixteen.computers.respectively.. CATxIP.1000.units.provide.true.global.control.for.the. created.to.allow.a.single.operator.to.take.full.control.of. These.numbers.can.be.increased.at.any.time.thanks.to. multiple.host.systems..Up.to.four.global.users.can.share
Summary of the content on the page No. 6
AdderView CATxIP 1000 features - front and rear The.AdderView.CATxIP.1000.units.pack.a.great.deal.of.functionality.into.a.compact. space..Both.models.occupy.half.of.a.single.1U.rack.space.and.provide.most.of.their. connectors.at.the.rear.face..The.smart.front.face.features.the.remote.user.link.port. and.the.operation.indicators. LOC REM VNC 100 LNK PWR IP network port The.port.by.which.global.users.are.linked.to.the. AdderView.CATxIP.1000.unit..This.intelligent. www.adder.com Ethernet.port.can.a
Summary of the content on the page No. 7
LOC REM VNC 100 LNK PWR www.adder.com What’s in the box AdderView CATxIP 000 AVX1008IP.–.8.computer.connections,.1.local.console.connection,.1.global.user.(network).connection AVX1016IP.–.16.computer.connections,.1.local.console.connection,.1.global.user.(network).connection Power adapter and country- specific power lead Four self-adhesive CD-ROM rubber feet What you may additionally need Computer Access Modules One.required.per.connected.computer..There.are.five. different.formats,.depend
Summary of the content on the page No. 8
16 15 14 13 8 7 6 5 OPTIONS 5V 2.0A 1 2 1 1 1 0 9 4 3 2 1 COMPUTER CONNECTIONS COMPUTER CONNECTION S 16 15 14 13 8 7 6 5 16 15 14 13 8 7 6 5 OPTIONS OPTIONS 5 V 2 .0 A 1 2 1 1 1 0 9 4 3 2 1 5V 2.0A 1 2 1 1 1 0 9 4 3 2 1 COMPUTER CONNECTIONS COMPUTER CONNECTIONS COMPUTER CONNECTIONS COMPUTER CONNECTION S 6 5 16 15 14 13 OPTIONS 5 V 2 1 2.0A ECTIONS HT Installation Mounting The.AdderView.CATxIP.1000.units.offer.three.main.mounting.methods: •. Supplied.four.self-adhesive.rubber.feet Single unit rac
Summary of the content on the page No. 9
Connections The.AdderView.CATxIP.1000.provides.a.great.deal.of.flexibility.in.its.configurations..This.chapter. details.the.various.connections.that.can.be.made.to.achieve.the.required.installation. Local Global LOCAL LOCAL user user USER USER page 9 page 10 LOCAL GLOBAL USER USER IP CAM CAM Power Multiple video POWER HOST in head connections COMPUTER IN page 12 page 17 CAM Cascading COMPUTER POWER multiple units SYSTEM SWITCH X200 page 14 Computer system Computer power (via CAM) control s
Summary of the content on the page No. 10
1 6 1 O P T IO N S 5 V 2 . 0 A 1 2 1 C O M P U T Local user LOCAL GLOBAL A.locally.connected.video.monitor,.keyboard. To connect the local user port USER USER (and.mouse).are.required.during.the.initial. 1. Position.a.suitable.video.monitor,.keyboard.and.mouse.in.the.vicinity.of.the. IP configuration..These.are.also.useful.during. AdderView.CATxIP.1000.unit.such.that.their.cables.will.easily.reach. POWER normal.use.to.allow.quick.local.control.of.any. 2. Attach.the.video.monitor,.keyboard.and.mo
Summary of the content on the page No. 11
Global user (IP network port) The.AdderView.CATxIP.1000.models.provide. To connect the Global user (IP network) port LOCAL GLOBAL an.autosensing.Ethernet.IP.port.that.can. USER USER 1. Depending.upon.where.in.the.network.the.AdderView.CATxIP.1000.is.being. operate.at.10.or.100Mbps,.according.to.the. connected,.run.a.category.5,.5e.or.6.link.cable.from.the.appropriate.hub.or. IP network.speed..The.AdderView.CATxIP.1000. router.to.the.AdderView.CATxIP.1000.unit. POWER models.are.designed.to.reside
Summary of the content on the page No. 12
Computer system (via CAM) LOCAL GLOBAL Each.computer.system.is.connected.to.the. 4. Attach.the.connector.of.the.cable. USER USER AdderView.CATxIP.1000.unit.via.a.Computer. run.to.the.socket.of.the.CAM. IP Access.Module.(CAM).and.standard.category.5,. POWER 5e.or.6.cabling..CAMs.are.available.in.various. Green indicator - power present IN formats.to.suit.differing.computer.system.types. Yellow indicator - signal activity CAM and.their.particular.connector.styles. Each.CAM.uses.Adder.Keep.Alive.t
Summary of the content on the page No. 13
16 1 OPTION S 5 V 2 .0 A 1 2 1 COMPUT Power in connection LOCAL GLOBAL The.AdderView.CATxIP.1000.unit.is.supplied. 2. Connect.the.IEC.connector.of.the.supplied.country-specific.power.lead.to. USER USER with.a.standard.5V.power.adapter..There.is.no. the.socket.of.the.power.adapter. IP on/off.switch.on.the.unit,.so.operation.begins. POWER as.soon.as.a.power.adapter.is.connected. IN CAM COMPUTER POWER SYSTEM SWITCH To connect the power supply 1. Attach.the.output.lead.from.the.power.adapter.to.the
Summary of the content on the page No. 14
16 1 OPTIONS 5V 1 2 1 2 .0 A COMPU T To connect and address the switch boxes Power control port LOCAL GLOBAL Note: The AdderView CATxIP 1000 unit can be powered on during this The.options.port.of.the.AdderView.CATxIP. USER USER procedure, however, the switch boxes should be switched off. The configuration 1000.can.be.used.to.connect.to.one.or.more. IP steps below are for the Adder EPS-M8 and EPS-S8 power switches. Other power optional.power.control.units..This.allows.you.to. switches may requ
Summary of the content on the page No. 15
Cascading multiple units X200 The.AdderView.CATxIP.1000.units. The cascade tree support.up.to.eight.or.sixteen. The.diagram.shows.how.an.AdderView.CATxIP.1000.unit.and. directly.connected.computer. multiple.AdderView.CATx.1000.units.can.be.cascaded.to.two.levels.. Computer.systems.can.be.connected.at.any.level..The.local.or.global. systems,.however,.this.is.by. users.can.access.computer.systems.situated.anywhere.within.the. no.means.the.limit..Instead.of. cascade.tree... connecting.computers.to.
Summary of the content on the page No. 16
KVM only 7 6 5 3 2 1 COMPUTER CONNECTIONS Connecting units in cascade The.method.for.cascading.AdderView.CATxIP.1000.and.AdderView.CATx. To connect units in cascade 1000.units.is.straightforward.and.requires.no.hardware.settings.or.lengthy. 1. Ensure.that.power.is.disconnected.from.the. configuration.process.. AdderView.CATxIP.1000.and.all.other.units. to.be.connected.... The.method.of.linking.units.is.the.same.regardless.of.the.cascade.level,.or. number.of.devices.attached..Put.simply:. 2. Conn
Summary of the content on the page No. 17
1203 Addressing computers in a cascade Computer.systems.connected.within.a.cascade.arrangement.are.addressed. using.up.to.four.digits,.two.for.each.cascade.level..The.pairs.of.digits.specify. which.of.the.COMPUTER CONNECTIONS.ports.on.each.of.the.AdderView.CATx. 1000.units.must.be.enabled.to.reach.a.specific.computer..In.the.diagram.given. here,.a.portion.of.the.previous.cascade.diagram.indicates.how.the.routes.to.two. particular.computers.are.formed.and.addressed.... AdderView CATxIP 1000 Port
Summary of the content on the page No. 18
Multiple video head connections LOCAL LOCAL Two.or.more.AdderView.CATxIP.1000.units.can.be.connected. USER USER together.so.that.they.operate.in.a.synchronised.manner.. Synchronised.operation.is.useful.for.applications.that.require. multiple.video.signals.to.be.switched.together..This.type.of. operation.is.usually.required.where.each.computer.is.fitted.with. multiple.video.cards.or.video.cards.with.multiple.video.heads.. Whenever.an.AdderView.CATxIP.1000.channel.is.switched,.it.sends. Slave Adde
Summary of the content on the page No. 19
16 1 OPTIONS 5V 2 .0 A 1 2 1 COMPU T Remote switching control The.port.switching.functions.of.the.AdderView.CATxIP. REMOTE CONTROL 1000.units.can.be.remotely.controlled.by.an.RS232.link.to. the.OPTIONS.port.on.the.rear.panel. The.sending.device.must.use.the.following.RS232. communication.settings:. AdderView CATxIP 000 Baud.rate:.. 19200.bps. rear panel Data.bits:. 8. Parity:. None. Cable from serial Stop.bits:. 1 control device No.handshaking.is.implemented,.however,.valid.command.character
Summary of the content on the page No. 20
HT Configuration Almost.all.configuration.and.operational.aspects.of.the.AdderView.CATxIP.1000. units.are.controlled.via.on-screen menu.displays.. Overall initial configuration When.setting.up.a.new.installation,.the.following.stages.are.recommended: 1. Enable the general ‘Security’ option. With security disabled (default setting), a local or remote user attached to the AdderView CATxIP 1000 will have full and unrestricted access to all computers and all AdderView CATxIP 1000 settings. In lar