Summary of the content on the page No. 1
CT-100C SERIES
SIX-SLOT VXIBUS CHASSIS
USER’S
MANUAL
P/N: 82-0102-000
Released November 16, 2007
VXI Technology, Inc.
2031 Main Street
Irvine, CA 92614-6509
(949) 955-1894
bus
Summary of the content on the page No. 2
VXI Technology, Inc. 2
Summary of the content on the page No. 3
www.vxitech.com TABLE OF CONTENTS INTRODUCTION Table of Contents......................................................................................................................................................3 Certification .........................................................................................................................................................4 Warranty .....................................................................................................
Summary of the content on the page No. 4
VXI Technology, Inc. CERTIFICATION VXI Technology, Inc. (VTI) certifies that this product met its published specifications at the time of shipment from the factory. VTI further certifies that its calibration measurements are traceable to the United States National Institute of Standards and Technology (formerly National Bureau of Standards), to the extent allowed by that organization’s calibration facility, and to the calibration facilities of other International Standards Organization mem
Summary of the content on the page No. 5
www.vxitech.com DECLARATION OF CONFORMITY Declaration of Conformity According to ISO/IEC Guide 22 and EN 45014 MANUFACTURER’S NAME VXI Technology, Inc. MANUFACTURER’S ADDRESS 2031 Main Street Irvine, California 92614-6509 PRODUCT NAME Six-Slot VXIbus Chassis MODEL NUMBER(S) CT-100C PRODUCT OPTIONS All PRODUCT CONFIGURATIONS All VXI Technology, Inc. declares that the aforementioned product conforms to the requirements of the Low Voltage Directive 73/23/EEC and the EMC
Summary of the content on the page No. 6
VXI Technology, Inc. GENERAL SAFETY INSTRUCTIONS Review the following safety precautions to avoid bodily injury and/or damage to the product. These precautions must be observed during all phases of operation or service of this product. Failure to comply with these precautions, or with specific warnings elsewhere in this manual, violates safety standards of design, manufacture, and intended use of the product. Service should only be performed by qualified personnel. TERMS AND SYMBOLS
Summary of the content on the page No. 7
www.vxitech.com WARNINGS (CONT.) To avoid electric shock or fire hazard, do not operate this product Avoid Electric Shock with the covers removed. Do not connect or disconnect any cable, probes, test leads, etc. while they are connected to a voltage source. Remove all power and unplug unit before performing any service. Service should only be performed by qualified personnel. This product is grounded through the grounding conductor of the Ground the Product power cord. To avoid
Summary of the content on the page No. 8
VXI Technology, Inc. SUPPORT RESOURCES Support resources for this product are available on the Internet and at VXI Technology customer support centers. VXI Technology World Headquarters VXI Technology, Inc. 2031 Main Street Irvine, CA 92614-6509 Phone: (949) 955-1894 Fax: (949) 955-3041 VXI Technology Cleveland Instrument Division VXI Technology, Inc. 7525 Granger Road, Unit 7 Valley View, OH 44125 Phone: (216) 447-8950 Fax: (216) 447-8951 VXI Technology Lake S
Summary of the content on the page No. 9
www.vxitech.com CT-100C Preface 9
Summary of the content on the page No. 10
Summary of the content on the page No. 11
www.vxitech.com SECTION 1 INTRODUCTION INTRODUCTION The CT-100C portable C-size VXIbus mainframe provides cost-effective test situations in a small footprint. When using VMIP ™ instruments such as DMMs, waveform generators, digitizers, etc., complete test scenarios can easily be configured. FIGURE 1-1: CT-100C SIX SLOT CHASSIS CT-100C Introduction 11
Summary of the content on the page No. 12
VXI Technology, Inc. GENERAL DESCRIPTION The CT-100C chassis is a portable, C-size, six-slot, VXIbus compatible chassis that conforms fully to VXIbus Specification Revision 2.0. The chassis employs a multi-layer backplane to ensure premium VXIbus and VMEbus performance and provides all power supplies required by the VXIbus specification. The CT-100C supports conventional existing rack designs through an optional rackmounting kit (see Section 1). The six-slot design minimizes the use of
Summary of the content on the page No. 13
www.vxitech.com FLEXIBILITY The CT-100C is designed to provide flexibility of use in bench-top and rackmount applications, as well as in portable environments. The outside cover is removable for easy access to the VXIbus modules during bench-top development, troubleshooting, or calibration. For rackmount applications, a rackmount kit allows the CT-100C to mount flush or be recessed four inches. A latched door is provided with the rackmount kit, which can be user-modified to accept connecto
Summary of the content on the page No. 14
VXI Technology, Inc. CT-100C MAINFRAME FEATURES FRONT PANEL FEATURES POWER SWITCH Feature 1 When elevated, the mainframe is in standby mode, where power is supplied to the mainframe, but not to the VXI modules. When depressed, power is supplied to both mainframe and VXI modules VOLTAGE INDICATORS Indicates whether specific backplane voltages are within specifications. See Figure 1-4 Feature 2 for details. FAN INDICATOR Feature 3 Indicates whether the fan voltages are within specifi
Summary of the content on the page No. 15
www.vxitech.com VOLTAGE MONITOR LEDS The power supply lines are monitored and displayed on the front panel, providing information pertaining to the chassis operational status. Power Voltage Monitors +5V +12V +24V +5V Stby -5.2V -12V -24V -2V FAN Voltage Monitor LEDs Green : Within Voltage Specifications Not Lit : Under Voltage Specifications Red : Over Voltage Specifications FAN LEDs Green : Within Voltage Specifications Not Lit : Under Voltage Specifications Red : Over Voltage Specific
Summary of the content on the page No. 16
VXI Technology, Inc. TABLE 1-1: J201 CONNECTOR PIN ASSIGNMENTS Pin Number Description † 1 +5 V Monitor † 2 -12 V Monitor † 3 -24 V Monitor † 4 -2 V Monitor 5 Remote Power Switch ‡ 6 +5 V Output ‡ 7 +12 V Output 8 +5 V Standby Input 9 Ground 10 Backplane Reset I/O 11 N/C 12 N/C 13 Fan OK Output † 14 +12 V Monitor † 15 +24 V Monitor † 16 -5.2 V Monitor 17 Ground 18 Remote Power Switch Return 19 Ground 20 Ground 21 +5 V Standby 22 Ground 23 AC Fail I/O 24 Ground 25 N/C
Summary of the content on the page No. 17
www.vxitech.com CT-100C SPECIFICATIONS GENERAL SPECIFICATIONS SIZE 6.96" (176.78 mm) W x 15.00" (381.00 mm) H x 21.3" D (541.02 mm) Six C-size VXIbus card slots (see Figure 1-6 for details) WEIGHT 22 lb / 10 kg VXIBUS VERSION 2.0 MTBF 100,000 hr MTTR 5 min ENVIRONMENTAL SPECIFICATIONS OPERATING LOCATION This chassis should be operated indoors in a controlled environment, protected from exposure to the elements (i.e. direct sunlight, precipitation, wind, etc.).
Summary of the content on the page No. 18
VXI Technology, Inc. POWER SPECIFICATIONS USEABLE POWER 500 W to 50 °C, derated by 2.5%/ °C above 50 °C DC SUPPLY VOLTAGE Peak Dynamic Induced Current Current Ripple/Noise Ripple Voltage (I ) (I ) Allowed Variation DC Load Noise MP MD +5 V 40 A 5 A +0.25 V / -0.125 V 50 mV 50 mV -5.2 V 10 A 5 A -0.26 V / +0.125 V 50 mV 50 mV -2 V 8 A 2 A -0.10 V / +0.72 V 50 mV 50 mV +12 V 8 A 2 A +0.60 V / -0.36 V 50 mV 50 mV -12 V 4 A 2 A -0.60 V / +0.36 V 50 mV 50 mV +24 V 4 A 2 A +1.
Summary of the content on the page No. 19
Fan at High Speed at Lo Fan w Speed www.vxitech.com 3.0 2.5 2.0 1.5 1.0 0.5 0.0 0 2.0 4.0 6.0 8.0 10.0 Airflow - liters/s * Covers all slots, unrestricted FIGURE 1-6: COOLING CAPACITY FOR CT-100C CT-100C Introduction 19 Pressure Drop - mm H O 2
Summary of the content on the page No. 20
VXI Technology, Inc. 21.000 (533.40) 8.100 (205.74) Power Voltage Monitors +5V +12V +24V +5V Stby -5.2V -12V -24V -2V FAN 16.425 (417.20) 14.979 (380.47) 0 1 2 3 4 5 CT-100C VXI Mainframe Note: Dimensions in parentheses are in millimeters. 0.343 (8.71) VXI Technology WARNING - TO PREVENT POSSIBLE ELECTRIC SHOCK HAZARD, DISCONNECT POWER ! CORD BEFORE R EMOVING THE POWER SUPPLY MODULE FROM THE MAINFRAME. ATTENTION - POUR EMP Ê CHER LE RISQUE POSSIBLE DE D É CHARGE É LECT RIQUE, DE