Paradyne BSX8000-5 user manual

User manual for the device Paradyne BSX8000-5

Device: Paradyne BSX8000-5
Category: Network Hardware
Manufacturer: Paradyne
Size: 0.24 MB
Added : 10/28/2014
Number of pages: 16
Print the manual

Download

How to use this site?

Our goal is to provide you with a quick access to the content of the user manual for Paradyne BSX8000-5. Using the online preview, you can quickly view the contents and go to the page where you will find the solution to your problem with Paradyne BSX8000-5.

For your convenience

If looking through the Paradyne BSX8000-5 user manual directly on this website is not convenient for you, there are two possible solutions:

  • Full Screen Viewing - to easily view the user manual (without downloading it to your computer), you can use full-screen viewing mode. To start viewing the user manual Paradyne BSX8000-5 on full screen, use the button Fullscreen.
  • Downloading to your computer - You can also download the user manual Paradyne BSX8000-5 to your computer and keep it in your files. However, if you do not want to take up too much of your disk space, you can always download it in the future from ManualsBase.
Paradyne BSX8000-5 User manual - Online PDF
Advertisement
« Page 1 of 16 »
Advertisement
Print version

Many people prefer to read the documents not on the screen, but in the printed version. The option to print the manual has also been provided, and you can use it by clicking the link above - Print the manual. You do not have to print the entire manual Paradyne BSX8000-5 but the selected pages only. paper.

Summaries

Below you will find previews of the content of the user manuals presented on the following pages to Paradyne BSX8000-5. If you want to quickly view the content of pages found on the following pages of the manual, you can use them.

Abstracts of contents
Summary of the content on the page No. 1

BSX8000-5 Broadband Services Switch
Installation Instructions
Document Number BSX8-A2-GZ40-10
March 2005
Contents
Software and Firmware License Agreement ...................................................... 1
Product Documentation Online .......................................................................... 3
Release Notes ................................................................................................... 3
BSX8000-5 Overview ...............................................

Summary of the content on the page No. 2

Software, including any copy of either. If you have executed a separate written agreement covering the Software supplied to you under this purchase, such separate written agreement shall govern. Paradyne Corporation (“Paradyne”) grants to you, and you (“Licensee”) agree to accept a personal, non-transferable, non-exclusive, right (without the right to sublicense) to use the Software, solely as it is intended and solely as incorporated in the Product purchased from Paradyne or its authorized

Summary of the content on the page No. 3

BSX8000-5 Overview The BSX8000-5 Broadband Services Switch provides multi-gigabit Ethernet uplink support capability, full-nonblocking switching throughput, and enhanced management functionality for the 4000E and 12000E Broadband Loop Carriers (BLCs). The BSX8000-5 supports four fixed 10/100/1000 RJ45 Ethernet interfaces and one MIM (Micro Interface Module) slot. Multiple MIM varieties are supported. The BSX8000-5 delivers a full 1 Gbps full duplex backplane connection to each access module

Summary of the content on the page No. 4

Unpacking and Inspecting the Equipment HANDLING PRECAUTIONS FOR ! STATIC-SENSITIVE DEVICES This product is designed to protect sensitive components from damage due to electrostatic discharge (ESD) during normal operation. When performing installation procedures, however, take proper static control precautions to prevent damage to equipment. If you are not sure of the proper static control precautions, contact your nearest sales or service representative. If there is any visible damage, do

Summary of the content on the page No. 5

Installing the BSX8000-5 in a BLC The 12000E is a 14-slot Broadband Loop Carrier (BLC). Slots 1–12 are reserved for access modules (such as the AIM24000-48) and slots U1 and U2 are reserved for uplink modules. Although not required for operational purposes, if redundancy is desired, two BSX8000-5 modules may be installed in the 12000E, in slots U1 and U2. (Note: For redundancy, the two uplink modules in the chassis must be identical models.) The 4000E is a five-slot BLC. Slots 1–4 are rese

Summary of the content on the page No. 6

MIM-4000F The MIM-4000F is a four-port fiber gigabit Ethernet interface connecting directly to the gigabit Ethernet switch in the BSX8000-5 uplink module. MIM-2E1 Plug your E1 cable into one of the RJ45 E1 ports on the MIM-2E1 faceplate. The MIM-2E1 connects to an E1 network extender provider unit (ENE2000-P or, for loop bonding, ENE2020-P) via a standard E1 line. Verify the connection: the Lnk (link) LED on the MIM-2E1 faceplate flashes green to indicate a network connection has been establ

Summary of the content on the page No. 7

Configuring Your Windows PC to Communicate with NMS To communicate with NMS, your PC’s Ethernet interface must be on the same subnet as the BSX8000-5. For example, to configure the IP address under Windows XP: Procedure 1. In the Windows task bar, click on the Start button, and then click on Control Panel. 2. Double-click on the Network Connections icon. 3. In the LAN or High-Speed Internet window, right-click on the icon corresponding to your network interface card (NIC) and select Proper

Summary of the content on the page No. 8

The NMS home page appears. 8 March 2005 BSX8-A2-GZ40-10

Summary of the content on the page No. 9

NMS Management Configuration Use the Management Configuration screen to set the unit’s IP address and other management parameters. Procedure To configure management parameters: 1. From the home screen, click on the Management Config button. The Management Configuration screen appears. 2. Select or enter the following parameters: Parameter Description IP Address Specify the management IP address for the DSLAM. Subnet Mask Specify the subnet mask for the IP address. Gateway Specify the first

Summary of the content on the page No. 10

Parameter Description Flood Configuration Flood refers to the method in which interface modules handle unknown unicasts, unknown broadcasts, and unknown multicasts for each port. Uplink – Any traffic with VLAN IDs that match a VLAN ID that has been configured to Uplink flood (default) will be allowed to flow from DSL ports to uplinks only (not DSL port to DSL port). VLAN – Any traffic with VLAN IDs that match a VLAN ID that has been configured to VLAN flood will be allowed to flow from

Summary of the content on the page No. 11

Connecting a PC Directly To connect a PC directly to the DSLAM to use the CLI: Procedure 1. Plug a DB9 to RJ45 adapter into the RS232 serial port on your PC. See DB9 to RJ45 Adapter Pinouts on page 14. 2. Connect one end of a straight-through RJ45 to RJ45 Ethernet cable into the adapter plugged into your PC, and the other end of the cable into the COM port on the face of the BSX8000-5. Launching the Terminal Emulation Program Launch the terminal emulation program on your PC and configure the

Summary of the content on the page No. 12

Table 1. CLI Commands (2 of 2) Command Description CLEAR_NVRAM If no interface modules are present in the chassis, clears Non-Volatile Random Access Memory, restoring the DSLAM to factory defaults. DISABLE_TELNET Disables access to the DSLAM using Telnet. DISABLE_TFTP Disables access to the DSLAM using Trivial File Transfer Protocol. DISABLE_WEB_SERVER] Disables access to the DSLAM using the web server. ENABLE_TELNET Enables access to the DSLAM using Telnet. ENABLE_TFTP Enables access to the

Summary of the content on the page No. 13

LED Indicators Table 2. LED States and Meanings LED State Indication Additional Information PWR (Power) Solid green BSX8000-5 uplink module is Both BLC power terminals are connected. receiving power Solid amber BSX8000-5 uplink module is Only one of the BLC power terminals is receiving power connected. No illumination No power The BSX8000-5 uplink module is not receiving power (the BLC may or may not be receiving power). OK Pulsing green* BSX8000-5 uplink module is operational Fan Solid gree

Summary of the content on the page No. 14

10/100/1000BaseT Connectors The uplink ports are 8-pin unkeyed modular jacks for a 10/100/1000BaseT interface. The MGMT port is an 8-pin modular jack supporting 10/100BaseT. Table 3. 10/100/1000 Pinouts Signal Pin Pin 1 Pin 8 Transmitted Data + 1 97-15449 Transmitted Data – 2 Received Data + 3 Unused 4 Unused 5 Received Data – 6 Unused 7 Unused 8 DB9 to RJ45 Adapter Pinouts To connect the COM port to the DB9 serial port of a PC, use an adapter wired as shown: Table 4. DB9 to RJ45 Ada

Summary of the content on the page No. 15

Regulatory Compliance for Class A Equipment The following regulatory compliance information applies to a BSX8000-5 as installed in a Paradyne BLC. US Federal Communications Commission (FCC) NOTE: This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment. This equipment ge

Summary of the content on the page No. 16

*BSX8-A2-GZ40-10* *BSX8-A2-GZ40-10* 16 March 2005 BSX8-A2-GZ40-10


Alternative user manuals
# User manual Category Download
1 Paradyne 8620 User manual Network Hardware 0
2 Paradyne 8777 User manual Network Hardware 0
3 Paradyne Broadband Services Switch User manual Network Hardware 0
4 Paradyne Hotwire 8620 GranDSLAM Installation Guide User manual Network Hardware 0
5 Paradyne 8747 User manual Network Hardware 0
6 Paradyne 8779 User manual Network Hardware 1
7 Paradyne Hotwire M/SDSL and HDSL2 Termination Units User manual Network Hardware 1
8 Paradyne FrameSaver User manual Network Hardware 0
9 Paradyne SLV 9128 User manual Network Hardware 1
10 Sony DDU1681S User manual Network Hardware 0
11 Sony VGP-MR200U/E User manual Network Hardware 1
12 Sony DDU1681S-0B User manual Network Hardware 1
13 Sony NAC-SV10I User manual Network Hardware 9
14 Sony NAC-SV10i User manual Network Hardware 0
15 Agilent Technologies 85107B User manual Network Hardware 2