Black Box ME805-C user manual

User manual for the device Black Box ME805-C

Device: Black Box ME805-C
Category: Network Hardware
Manufacturer: Black Box
Size: 0.1 MB
Added : 1/27/2014
Number of pages: 27
Print the manual

Download

How to use this site?

Our goal is to provide you with a quick access to the content of the user manual for Black Box ME805-C. Using the online preview, you can quickly view the contents and go to the page where you will find the solution to your problem with Black Box ME805-C.

For your convenience

If looking through the Black Box ME805-C user manual directly on this website is not convenient for you, there are two possible solutions:

  • Full Screen Viewing - to easily view the user manual (without downloading it to your computer), you can use full-screen viewing mode. To start viewing the user manual Black Box ME805-C on full screen, use the button Fullscreen.
  • Downloading to your computer - You can also download the user manual Black Box ME805-C to your computer and keep it in your files. However, if you do not want to take up too much of your disk space, you can always download it in the future from ManualsBase.
Black Box ME805-C User manual - Online PDF
Advertisement
« Page 1 of 27 »
Advertisement
Print version

Many people prefer to read the documents not on the screen, but in the printed version. The option to print the manual has also been provided, and you can use it by clicking the link above - Print the manual. You do not have to print the entire manual Black Box ME805-C but the selected pages only. paper.

Summaries

Below you will find previews of the content of the user manuals presented on the following pages to Black Box ME805-C. If you want to quickly view the content of pages found on the following pages of the manual, you can use them.

Abstracts of contents
Summary of the content on the page No. 1

AUGUST 2000
ME800A
ME800A-R2
ME805-C
ME805-C-R2
ME810
Short-Haul Modem B
(SHM-B Async)
CUSTOMER SUPPORT INFORMATION
Order toll-free in the U.S.: Call 877-877-BBOX (outside U.S. call 724-746-5500)
FREE technical support 24 hours a day, 7 days a week: Call 724-746-5500 or fax 724-746-0746
Mailing address: Black Box Corporation, 1000 Park Drive, Lawrence, PA 15055-1018
Web site: www.blackbox.com • E-mail: info@blackbox.com
NORMAL
TD RD
LOOPBACK
ASYNC SHORT HAUL MODEM

Summary of the content on the page No. 2

SHM-B ASYNC FEDERAL COMMUNICATIONS COMMISSION AND INDUSTRY CANADA RADIO FREQUENCY INTERFERENCE STATEMENTS This equipment generates, uses, and can radiate radio frequency energy and if not installed and used properly, that is, in strict accordance with the manufacturer’s instructions, may cause interference to radio communication. It has been tested and found to comply with the limits for a Class A computing device in accordance with the specifications in Subpart J of Part 15 of FCC rules, which

Summary of the content on the page No. 3

SHM-B ASYNC NORMAS OFICIALES MEXICANAS (NOM) ELECTRICAL SAFETY STATEMENT INSTRUCCIONES DE SEGURIDAD 1. Todas las instrucciones de seguridad y operación deberán ser leídas antes de que el aparato eléctrico sea operado. 2. Las instrucciones de seguridad y operación deberán ser guardadas para referencia futura. 3. Todas las advertencias en el aparato eléctrico y en sus instrucciones de operación deben ser respetadas. 4. Todas las instrucciones de operación y uso deben ser seguidas. 5. El aparato el

Summary of the content on the page No. 4

SHM-B ASYNC 10. El equipo eléctrico deber ser situado fuera del alcance de fuentes de calor como radiadores, registros de calor, estufas u otros aparatos (incluyendo amplificadores) que producen calor. 11. El aparato eléctrico deberá ser connectado a una fuente de poder sólo del tipo descrito en el instructivo de operación, o como se indique en el aparato. 12. Precaución debe ser tomada de tal manera que la tierra fisica y la polarización del equipo no sea eliminada. 13. Los cables de la fuente

Summary of the content on the page No. 5

SHM-B ASYNC TRADEMARKS USED IN THIS MANUAL Any trademarks mentioned in this manual are acknowledged to be the property of the trademark owners. 4

Summary of the content on the page No. 6

SHM-B ASYNC 1. Specifications Transmission — Data Rate (bps) Distance (miles/km) 19,200 1/1.6 9600 2/3.2 4800 3/4.8 2400 4/6.4 NOTE:The above specifications are valid for 24- or 26-AWG unshielded twisted-pair telephone cable insulated by polyethylene with a mutual capacitance of 0.083 µf/mile. Shielded twisted-pair cable will reduce the distance to one-third of the table value, due to the additional capacitance contributed by the cable’s shielding. Actual distances may vary depending on your sp

Summary of the content on the page No. 7

SHM-B ASYNC end of the loop. Interface is switch-selectable for DTE/DCE configuration (pins 2 and 3 are reversed) Connectors — (1) DB25 female, (1) 5-screw terminal block Diagnostics — Loopbacks provided by a front-panel switch: Analog loopback on a 4-wire loop and digital loopback on equipment interface (EIA-232) Status Indication — Two bi-color LEDs indicate the status of the transmitter and receiver. A green light indicates a “low” logic level (-3 to -25V) on the EIA-232 interface; a red ligh

Summary of the content on the page No. 8

SHM-B ASYNC Primary: 115 VAC ±10%, 60 Hz, 5 watts (12 watts max.); Primary: 230 VAC ±10%, 50/60 Hz; Secondary: 17 VAC, 700 mA Size — Standalone: 1.4"H x 4.25"W x 4.5"D (3.8 x 10.9 x 11.7 cm); Rackmount: 5.25"H x 17"W x 9"D (13 x 43 x 23 cm) Weight — Standalone: 1.3 lb. (0.6 kg), including transformer; Rackmount: 3.7 lb. (1.7 kg), including transformer 7

Summary of the content on the page No. 9

SHM-B ASYNC 2. Introduction The Short-Haul Modem Model B Async (SHM-B Async) is an asynchronous full-duplex 4-wire line driver/receiver which allows two EIA-232 devices to communicate at distances of up to 4 miles and at data speeds of up to 19,200 bps. In addition to the transmitter and receiver circuits, the SHM-B Async includes EIA-232 control line interfaces, status monitor LEDs, and a loopback switch. The SHM-B is available in both a standalone version (ME800A) and a rackmount version (ME80

Summary of the content on the page No. 10

SHM-B ASYNC 3. Installation Installation involves three basic steps: four-wire connections; EIA-232 connection; switch settings. 3.1 Four-Wire Connections Figure 1 shows the location of the terminal block on the circuit board. Refer to Figure 2 to make the proper connections between two SHM-B units. NOTE: Transmit + (TX+) on one modem is wired to Receive + (RX+) on the other modem; Transmit - (TX-) is wired to Receive - (RX-). A ground connection is optional. 1. If the unit is assembled, separat

Summary of the content on the page No. 11

RX+ RX- TX+ TX- GROUND SHM-B ASYNC 5. Insert the wires into the terminal strip; tighten the screw terminals. 6. After you have made all four connections, wrap the nylon cable tie (packaged with the SHM-B) around the wires. Pull the tie tight around the wires to secure them to the printed circuit board. Trim the excess nylon tie with wire cutters or scissors. J1 RS-232 CONNECTOR EN JUMPER DIS RTS/DTR DCE CONTROL DTE/DCE DTE S2 (LOOPBACK) Figure 1. SHM-B board; 5-screw terminal block. 10

Summary of the content on the page No. 12

SHM-B ASYNC TX+ RX+ TX- RX- RX+ TX+ RX- TX- SHM #1 SHM #2 Figure 2. Wiring diagram for two SHM-B units. 3.2 EIA-232 Connection Connect the SHM-B to your computer or terminal with a standard EIA-232 cable and DB25 connectors. Refer to your equipment’s installation manual if you need information on the exact EIA-232 signals required for your equipment. Often, it is best to use only the Transmit Data (TD), Receive Data (RD), and ground lines if your equipment does not require the use of the control

Summary of the content on the page No. 13

SHM-B ASYNC Table 1. EIA-232 Pin Connections on SHM-B Pin Number Signal Name 1 Protective Ground 2 Transmit Data/Receive Data (TD/RD)* 3 Receive Data/Transmit Data (RD/TD)* 4 Request to Send (RTS) 5 Clear to Send (CTS) 6 Data Set Ready (DSR) 7 Signal Ground 8 Carrier Detect (CD) 20 Data Terminal Ready (DTR) *TD and RD can be reversed using the DTE/DCE switch, S1 on the circuit board. See Section 3.3 for details. 3.3 Switch Settings Refer to Figure 1 in this chapter. Switch S1 is used to reverse

Summary of the content on the page No. 14

SHM-B ASYNC information concerning its DTE/DCE setting. Table 2 gives the EIA-232 pinning of the SHM-B with the DTE/DCE switch in the DCE position. Table 2. Pinning with DTE/DCE switch in the DCE position. PIN NUMBER SIGNAL NAME DIRECTION 1 Protective Ground ————— 2 Transmitted Data TD* To DCE 3 Received Data RD* From DCE 4 Request to Send (RTS) To DCE 5 Clear to Send (CTS) From DCE 6 Data Set Ready (DSR) From DCE 7 Signal Ground ————— 8 Received Line Signal Detector From DCE 20 Data Terminal Re

Summary of the content on the page No. 15

SHM-B ASYNC 3.4 Flow Control The SHM-B uses a clever, yet simple way to allow this unit to work with a broad line of equipment. STANDARD EIA-232C HANDSHAKING (RTS/DTR CONTROL JUMPER IN EN POSITION) The individual SHM-B modems force their own DTR, RTS, CTS, and DSR control lines HIGH (>+3V) when: • The twisted-pair wires are installed correctly. • Power is applied to both modems. • No computer devices are attached to the modems. This forces DCD HIGH on the remote modem; thus, the remote modem kno

Summary of the content on the page No. 16

SHM-B ASYNC Because DTR, DSR, RTS, and CTS are tied together internally, dropping any one of these four signals to a negative state will also drop DCD on the remote side to a negative state. DCD will also go LOW if the remote SHM-B is powered down, or if the twisted-pair wire is broken. X-ON/X-OFF MODE (RTS/DTR CONTROL JUMPER IN DIS POSITION) If X-ON/X-OFF characters are used for handshaking control, rather than hardware logic levels, move the RTS/DTR control jumper to the DIS position. Typicall

Summary of the content on the page No. 17

SHM-B ASYNC 4. Operation After completing the wiring and configuration procedure, slide the printed circuit card back into the case while pulling the data and power cables through the holes in the back panel. The front panel will snap into the front of the case when the printed circuit board has been completely pushed to the back of the case. Connect the SHM-B to your equipment, then plug the wall transformer into its power source. Check the SHM- B operation at both ends of the loop by pressing

Summary of the content on the page No. 18

SHM-B ASYNC When in loopback mode, the switch button indicator will appear to the sender. If a CRT terminal is connected to the SHM-B, typing characters on the keyboard should result in the same characters appearing on the CRT screen. If no characters appear, check your EIA-232 connections and the setting of S1. See Figure 3 for an illustration of the loopback mode. The TD and RD LEDs on the front panel of your SHM-B indicate the status of the SHM-B transmitter and receiver, respectively. Green

Summary of the content on the page No. 19

SHM-B ASYNC 5. Rackmount Installation The SHM-B Async Card is a rack mount unit (ME805-C) that installs in a standard 19-inch panel rack. (You can use the SHM-B Rack [ME810], which can hold up to 16 cards.) The SHM-B Async Card will occupy 5.25 inches of vertical rack space, and is 9 inches deep. To install the SHM-B Rack, first remove the acrylic front panel by pulling out the six plunger latches on the front of the panel, then pulling on opposite-side plungers to loosen and remove the panel. L

Summary of the content on the page No. 20

SHM-B ASYNC easiest access to the terminals, switches, etc. After a SHM-B Card is wired, it can then be inserted into an open slot in the SHM-B rack. Be certain that the circuit board has mated with the power pins on the SHM-B rack before applying force to fully seat the board; otherwise you may damage the board and power pins. When all boards have been wired and plugged into the rack, plug the wall transformer into its power source. You should be able to communicate as described in Chapter 4. W


Alternative user manuals
# User manual Category Download
1 Black Box 8-/16-/24-Port 10/100 PoE PSE Web Smart Switch User manual Network Hardware 0
2 Black Box 10Base-T Transceiver Stand-Alone model User manual Network Hardware 2
3 Black Box AC1132A User manual Network Hardware 1
4 Black Box 24+4-PORT GIGABIT SWITCH MANAGED W/4 SFP + 10G User manual Network Hardware 0
5 Black Box 10/100BASE-T Ethernet Extender over VDSL2 User manual Network Hardware 2
6 Black Box 2-Port and 4-Port Audio/Video Splitters User manual Network Hardware 0
7 Black Box 8x8 DVI-D Matrix Switches User manual Network Hardware 0
8 Black Box AC150A-4 User manual Network Hardware 0
9 Black Box 4-Port RJ-45 Modem Splitter (RS-232 on RJ-45) User manual Network Hardware 3
10 Black Box AC151AE-REM User manual Network Hardware 0
11 Black Box AC650A-2 User manual Network Hardware 1
12 Black Box AC650A-4 User manual Network Hardware 0
13 Black Box ACR1000A-CTL User manual Network Hardware 0
14 Black Box AC151A-REM User manual Network Hardware 0
15 Black Box AC650A-2-UK User manual Network Hardware 0
16 Sony DDU1681S User manual Network Hardware 0
17 Sony VGP-MR200U/E User manual Network Hardware 1
18 Sony DDU1681S-0B User manual Network Hardware 1
19 Sony NAC-SV10I User manual Network Hardware 9
20 Sony NAC-SV10i User manual Network Hardware 0