Omron E7 user manual

User manual for the device Omron E7

Device: Omron E7
Category: Network Card
Manufacturer: Omron
Size: 1.65 MB
Added : 12/15/2013
Number of pages: 12
Print the manual

Download

How to use this site?

Our goal is to provide you with a quick access to the content of the user manual for Omron E7. Using the online preview, you can quickly view the contents and go to the page where you will find the solution to your problem with Omron E7.

For your convenience

If looking through the Omron E7 user manual directly on this website is not convenient for you, there are two possible solutions:

  • Full Screen Viewing - to easily view the user manual (without downloading it to your computer), you can use full-screen viewing mode. To start viewing the user manual Omron E7 on full screen, use the button Fullscreen.
  • Downloading to your computer - You can also download the user manual Omron E7 to your computer and keep it in your files. However, if you do not want to take up too much of your disk space, you can always download it in the future from ManualsBase.
Omron E7 User manual - Online PDF
Advertisement
« Page 1 of 12 »
Advertisement
Print version

Many people prefer to read the documents not on the screen, but in the printed version. The option to print the manual has also been provided, and you can use it by clicking the link above - Print the manual. You do not have to print the entire manual Omron E7 but the selected pages only. paper.

Summaries

Below you will find previews of the content of the user manuals presented on the following pages to Omron E7. If you want to quickly view the content of pages found on the following pages of the manual, you can use them.

Abstracts of contents
Summary of the content on the page No. 1

Y203-EN2-02-Katalog.book Seite 365 Mittwoch, 24. Mai 2006 2:22 14
3G3RV-P10ST@-E
G7/F7/L7/E7 inverter PLC
The OMRON PLC technology embedded in
the OMRON Yaskawa inverter family
� OMRON PLC programmability in the
OMRON Yaskawa inverters.
� Flexibility and intelligence in the OMRON Yaskawa
inverter family.
� Wireless installation and seamless access to the
inverter parameters and analogue/digital inputs and
outputs.
� OMRON Compobus/S fieldbus inside. Thus, able to
control up to 256I

Summary of the content on the page No. 2

Y203-EN2-02-Katalog.book Seite 366 Mittwoch, 24. Mai 2006 2:22 14 Type designation PLC inverter 3G3RV-P10ST8-DRT-E DeviceNet slave Inverter series Number of I/O's -No Options DRT Yes Output RTC RS422 Remarks - NPN NO NO 1NPN NO YES 2 NPN YES NO 3 NPN YES YES 5 PNP NO NO 6 PNP NO YES 7PNP YES NO 8 PNP YES YES Standard Specifications Specifications by product Item 3G3RV-P10ST8-E 3G3RV-P10ST8-DRT-E PLC core CPM2C-S CPM2C-S Inputs 6 24 VDC inputs 6 24 VDC inputs Outputs 4 sourcing/PNP transistor

Summary of the content on the page No. 3

Y203-EN2-02-Katalog.book Seite 367 Mittwoch, 24. Mai 2006 2:22 14 Item Specifications 3G3RV-P10ST8-E 3G3RV-P10ST8-DRT-E Link bits (LR area) 256 bits: LR 0000 to LR 1515 (words LR 00 to LR 15) Timers/counters 256 timers/counters (TIM/CNT 000 to TIM/CNT) 1-ms timers: TMHH(--) 10-ms timers: TIMH(15) 100-ms timers: TIM 1-s/10-s timers: TIML(--) Decrementing counters: CNT Reversible counters: CNTR(12) CompoBus/S master functions Remote I/O devices can be allocated up to 256 I/O points (128 inputs

Summary of the content on the page No. 4

Y203-EN2-02-Katalog.book Seite 368 Mittwoch, 24. Mai 2006 2:22 14 Item Specifications 3G3RV-P10ST8-E 3G3RV-P10ST8-DRT-E Power-interruption hold function Holds the contents of HR, AR, CNT, and DM areas. Memory backup (see notes 1 and 2.) Flash memory: Program, read-only DM area, and PC setup Memory backup: The read/write DM area, HR area, AR area, and counter values are backed up. (The battery has a 5-year lifetime at 25 °C and it is replaceable.) Self-diagnostic function CPU errors, memory e

Summary of the content on the page No. 5

Y203-EN2-02-Katalog.book Seite 369 Mittwoch, 24. Mai 2006 2:22 14 The minimum pulse widths for inputs IN00000 (A-phase input) and IN00001 (B-phase input) are as follows: Pulse plus direction input mode, Differential phase mode up/down inputmode, Increment mode 100 µs min. 50 µs min. ON 90% Phase A 50% ON 90% OFF 10% 50% OFF 10% ON 90% Phase B 50% 12.5 µs 12.5 µs OFF 10% min. min. T T T T 1 2 3 4 T T T T : 12.5 µs min. 1 2 3 4 The minimum pulse width for input IN00002 (Z-phase input)

Summary of the content on the page No. 6

Y203-EN2-02-Katalog.book Seite 370 Mittwoch, 24. Mai 2006 2:22 14 Operation CPU unit component descriptions 15. Low battery detection switch 14. Battery 17. DeviceNet indicators 18. CompoBus/S indicators 1. DIP switch 5. PLC status indicators 4. High-speed counter indicators 3. Output indicators 2. Input indicators 16. DeviceNet node address 8. DeviceNet port 12. Digital I/O and 13. FE connection 6. Communications port encoder interface 9. RS-422/485 port 11. CompoBus/S port 10. Terminating r

Summary of the content on the page No. 7

Y203-EN2-02-Katalog.book Seite 371 Mittwoch, 24. Mai 2006 2:22 14 6. Communications port 11. CompoBus/S port Connects the PLC to a programming device (including programming Terminal arrangement consoles), host computer, or standard external device. Use a proper connecting cable (CPM2C-CN111, CS1W-CN114, CS1W-CN118, or BDH 4 2 CS1W-CN226). Note: 1. A CQM1H-PRO01-E programming console can be connect- BDL 3 1 ed directly to the PLC. 2. A C200H-PRO27-E programming console can be connected Use s

Summary of the content on the page No. 8

Y203-EN2-02-Katalog.book Seite 372 Mittwoch, 24. Mai 2006 2:22 14 Dimensions Application examples G7 + PLC Varispeed G7 is the OMRON Yaskawa solution using 3 level PWM control technology that provides lower surge voltage, low leakage current, low bearing current, low acoustic noise and better EMC. By combining with PLC option board, it is the ideal solution for winding/unwiding applications, handling / transfer / palletizer point-to-point positioning applications, press control applicatio

Summary of the content on the page No. 9

Y203-EN2-02-Katalog.book Seite 373 Mittwoch, 24. Mai 2006 2:22 14 F7 + PLC The F7 drive is a flux vector control inverter. It is intended to handle every conventional drive application found in a typical industrial manufacturing plant from simple variable torque pumping to sophisticated networked material handling. By combining with PLC option board, is ideal solution winding/unwiding applications, handling/ transfer/ palletizer point-to-point positioning applications, food processing, pac

Summary of the content on the page No. 10

Y203-EN2-02-Katalog.book Seite 374 Mittwoch, 24. Mai 2006 2:22 14 L7 + PLC The L7 is the ultimate drive for lift applications up to 3m/s. High starting torque, silent operation, lift-specific operator interface and operation with both AC and PM motors are standard features of the L7 inverter. By combining with PLC option board, it is the ideal solution for controlling distributed I/O’s, lift cabin HMI, GSM modem to send alarms for example.. L7 + PLC in lift application example L7 + PLC Co

Summary of the content on the page No. 11

Y203-EN2-02-Katalog.book Seite 375 Mittwoch, 24. Mai 2006 2:22 14 Ordering information 3G3IV-PCN329-E 3G3IV-PCN126/326 CX-One Inverter to PC cable Digital operator extension cable C C C Varispeed CompoBus/S slaves SRT2-ID SRT2-OD SRT2-ROC SRT2-ROF SRT2-ID_CL SRT2-OD_CL SRT2-AD G7/F7/L7/E7 SRT2-DA A B Inverter PLC G7/F7/L7/E7 inverter PLC Specifications Model Inputs Ouptuts RTC Compobus/S master RS422 port DeviceNet slave 6 4 Yes Yes Yes No 3G3RV-P10ST8-E 6 4 Yes Yes NO Yes 3G3RV-P10ST8

Summary of the content on the page No. 12

Y203-EN2-02-Katalog.book Seite 376 Mittwoch, 24. Mai 2006 2:22 14 C Compobus/S slaves Product Appearance Specifications Model Digital I/O terminals 4 NPN inputs (+ common) SRT2-ID04 4 PNP inputs (– common) SRT2-ID04-1 4 NPN outputs (– common) SRT2-OD04 4 PNP outputs (+ common) SRT2-OD04-1 8 NPN inputs (+ common) SRT2-ID08 8 PNP inputs (– common) SRT2-ID08-1 8 NPN outputs (– common) SRT2-OD08 8 PNP outputs (+ common) SRT2-OD08-1 16 NPN inputs (+ common) SRT2-ID16 16 PNP inputs (– common) SRT2-


Alternative user manuals
# User manual Category Download
1 Omron C200HW-CLK21 User manual Network Card 21
2 Omron CJ1W-CLK21-V1 User manual Network Card 41
3 Omron CJ1W-ETN11 User manual Network Card 20
4 Omron CPU Unit CJ2 User manual Network Card 11
5 Omron CQM1H-CLK21 User manual Network Card 44
6 Omron CS1W-ETN11 User manual Network Card 29
7 Omron CS CJ1W-ETN21 User manual Network Card 44
8 Omron CS1W-ETN01 User manual Network Card 8
9 Omron E5ZN-DRT User manual Network Card 18
10 Omron CS1W-CLK21-V1 User manual Network Card 16
11 Omron CS/CJ Series User manual Network Card 0
12 Omron CS1W-ETN21 User manual Network Card 39
13 Omron CS1W-RPT01 User manual Network Card 8
14 Omron CVM1-CLK21 User manual Network Card 3
15 Omron G7, F7, L7, E7 User manual Network Card 25
16 Sony BTA-NW1A User manual Network Card 2
17 Sony BKMW-E3000 User manual Network Card 2
18 Sony AC-SQ950D User manual Network Card 0
19 Sony BBV RX100 User manual Network Card 3
20 Sony CLIE A-AVZ-100-11 User manual Network Card 1