Paradyne ACCULINK 3165 DSU/CSU user manual

User manual for the device Paradyne ACCULINK 3165 DSU/CSU

Device: Paradyne ACCULINK 3165 DSU/CSU
Category: Network Card
Manufacturer: Paradyne
Size: 0.2 MB
Added : 12/15/2013
Number of pages: 18
Print the manual

Download

How to use this site?

Our goal is to provide you with a quick access to the content of the user manual for Paradyne ACCULINK 3165 DSU/CSU. Using the online preview, you can quickly view the contents and go to the page where you will find the solution to your problem with Paradyne ACCULINK 3165 DSU/CSU.

For your convenience

If looking through the Paradyne ACCULINK 3165 DSU/CSU user manual directly on this website is not convenient for you, there are two possible solutions:

  • Full Screen Viewing - to easily view the user manual (without downloading it to your computer), you can use full-screen viewing mode. To start viewing the user manual Paradyne ACCULINK 3165 DSU/CSU on full screen, use the button Fullscreen.
  • Downloading to your computer - You can also download the user manual Paradyne ACCULINK 3165 DSU/CSU to your computer and keep it in your files. However, if you do not want to take up too much of your disk space, you can always download it in the future from ManualsBase.
Paradyne ACCULINK 3165 DSU/CSU User manual - Online PDF
Advertisement
« Page 1 of 18 »
Advertisement
Print version

Many people prefer to read the documents not on the screen, but in the printed version. The option to print the manual has also been provided, and you can use it by clicking the link above - Print the manual. You do not have to print the entire manual Paradyne ACCULINK 3165 DSU/CSU but the selected pages only. paper.

Summaries

Below you will find previews of the content of the user manuals presented on the following pages to Paradyne ACCULINK 3165 DSU/CSU. If you want to quickly view the content of pages found on the following pages of the manual, you can use them.

Abstracts of contents
Summary of the content on the page No. 1

ACCULINK 3165 DSU/CSU
QUICK REFERENCE
Document No. 3165-A2-GL11-30

Summary of the content on the page No. 2

Copyright  1998 Paradyne Corporation. All rights reserved. Printed in U.S.A. Notice This publication is protected by federal copyright law. No part of this publication may be copied or distributed, transmitted, transcribed, stored in a retrieval system, or translated into any human or computer language in any form or by any means, electronic, mechanical, magnetic, manual or otherwise, or disclosed to third parties without the express written permission of Paradyne Corporation, 8545 126th Avenue

Summary of the content on the page No. 3

TM ACCULINK 3165 DSU/CSU Quick Reference Document Number 3165-A2-GL11-30 January 1998 Quick Start Procedure The following procedure is for experienced DSU/CSU users who are familiar with the 3165 DSU/CSU installation process and have no special requirements for their application. See the ACCULINK 316x Data Service Unit/Channel Service Unit Operator’s Guide (Document No. 3160-A2-GB21) for more information. 1. Attach the power cord to the rear of the DSU/CSU and the other end to a grounded 115 Vac

Summary of the content on the page No. 4

Modem PSTN Modem or or PC Terminal SNMP Manager Workstation Front Modem Modem Panel 3165 DSU/CSU COM Network Port Port Port Port 3165 COM PORT MODEM NETWORK POWER AUX PORT DTE DSU/CSU NEC CLASS 2 CAUTION: AUX PORT OR COM PORT MUST NOT BE CONNECTED TO PSTN OR T1 NETWORK Network INPUT Port T1 Network COM Port Power Serial COM PORT MODEM NETWORK POWER AUX PORT DTE 3165 Port NEC DSU/CSU CLASS 2 CAUTION: AUX PORT OR COM PORT MUST NOT BE CONNECTED TO PSTN OR T1 NETWORK INPUT Power Network or Port

Summary of the content on the page No. 5

Configuration Options Configuration options are accessed from the Configuration branch of the front panel menu. DSU ESF Stat Test Cnfig Ctrl Rel DevHS STest Perf TStat LED ID Reset Passwd Call ClrReg CID DL Telco User Prtn T1 Prtn Near Far Dial Disc ChDir Rlpbk Lpbk Ptrns Lamp Cur Intvl User Prt1 24Tot Cur Intvl 1 . . 5,A 1 . . 5,A Near Far 8Tot Abort Send Mon (Directory) (Directory) QRSS 511 LLBUP 54UP FT1UP LLBDN 54DN FT1DN QRSS 1in8 511 Abort LLB PLB DLB RLB DCLB DTLB Load Edit Area From: Act

Summary of the content on the page No. 6

Table 1. Port Configuration Options (1 of 2) Option Factory 1 Factory 2 Comments/Description E530 E530 V.35 V.35 Selects the Selects the por port t t type: ype: EIA-530A, EIA-530A, Port T Port Type: ype: V.35, RS449, or X.21. RS449 RS449 X.21 X.21 Nx64 Nx64 E Enables the nables the por port to either Nx56 or t to either Nx56 or Base Base Rate: Rate: Nx64 rates. Nx56 Nx56 Disab Disab V.54 V.54 Network-initiated DCLB, allows , Net Net DCLB: DCLB: DCLB DCLB to be controlled by inband to be contro

Summary of the content on the page No. 7

Table 1. Port Configuration Options (2 of 2) Option Factory 1 Factory 2 Comments/Description 10E–4 10E–4 10E–5 10E–5 Err Rate: 10E–6 10E–6 Selects the error rate threshold for (Excessive (Excessive Error Error Excessive Excessive Error Rate Alarm. Error Rate Alarm 10E–7 10E–7 Rate) ae) 10E–8 10E–8 10E–9 10E–9 Table 2. Network Interface Configuration Options Option Factory 1 Factory 2 Comments/Description D4 D4 NET Framing: Selects D4 or ESF framing format NET Framing: Selects D4 or ESF frami

Summary of the content on the page No. 8

Table 3. Channel Configuration Options (1 of 2) Option Factory 1 Factory 2 Comments/Description Block Block Determines how channels are Determines how channels are ACAMI ACAMI Assign By: Assign By: assigned: contiguous blocks, assigned: contiguous blocks, ACAMI ACAMI or individual channels. i di id l h l Chan Chan Option Factory 1 Factory 2 Comments/Description 64 (56) 64 (56) 128 (112) 128 (112) 192 (168) 192 (168) 256 (224) 256 (224) 320 (280) 320 (280) 384 (336) 384 (336) 448 (392) 448 (392

Summary of the content on the page No. 9

Table 3. Channel Configuration Options (2 of 2) Clears (unassigns) channels for Clear Clear this port. N1 (D1) N1 (D1) N2 (D2) N2 (D2) N3 (D3) N3 (D3) N4 (D4) N4 (D4) N5 (D5) N5 (D5) N6 (D6) N6 (D6) N7 (D7) N7 (D7) N8 (D8) N8 (D8) N9 (D9) N9 (D9) N10 (D10) N10 (D10) N11 (D11) N11 (D11) Start At: This configuration option appears if N12 (D12) N12 (D12) the “Assigned By” configuration N13 (D13) N13 (D13) option is Block or ACAMI. N14 (D14) N14 (D14) N15 (D15) N15 (D15) N16 (D16) N16 (D16) N17 (D

Summary of the content on the page No. 10

Table 4. General Configuration Options Option Factory 1 Factory 2 Comments/Description Enab Enab Gen Y Gen Yellow: ellow: Y Yellow alarm is ellow alarm is genera generated b ted by y the the (Generate Yellow) DSU/CSU on LOS, LOF, or AIS. Disab Disab NET NET DTE DTE Selects Selects the clock source to be the clock source to be Prt1 Prt1 Clock Src: Clock Src: used as the master clock for the used as the master clock for the DSU/CSU. DSU/CSU Int Int Ext Ext 2048 2048 Selects the clock rate of the

Summary of the content on the page No. 11

Table 5. User Configuration Options (1 of 3) Option Factory 1 Factory 2 Comments/Description Enab Enab Allows bypass of self-test on Allows bypass of self-test on Self-T Self-Test: est: initialization. Disab Disab Enab Enab Controls Controls whether front panel whether front panel FP Access: FP Access: access or display is allowed. Disab Disab Enab Enab Controls whether front panel Controls whether front panel FP Pass: FP Pass: pass-through is allowed. Disab Disab Enab Enab Controls Controls w

Summary of the content on the page No. 12

Table 5. User Configuration Options (2 of 3) Option Factory 1 Factory 2 Comments/Description 1 1 CStop CStop Bits: Bits: Selects the number of stop bits for 1.5 1.5 (Communication Port (Communication Port the COM the COM por port. t. Stop Bits) St Bit ) 2 2 Yes Yes S Spec pecifies whether the COM ifies whether the COM por port t Ignore DTR: Ignore DTR: ignores DTR. No No Enab Enab CmInActTm: Specifies whether the p (COM (COM Port Inactivity Port Inactivity communication communication port disc

Summary of the content on the page No. 13

Table 5. User Configuration Options (3 of 3) Option Factory 1 Factory 2 Comments/Description 5 5 MoDiscTm: Up Up Specifies the period of inactivity Specifies the period of inactivity (M (Modem Port odem Port (1 (1 to 60 minutes) that causes a t 60 i t ) th t Disconnect Time) Down Down d disconnect if MInActTm is enabled. sco ec c s e ab ed Save Save Enab Enab Specifies whether the DSU/CSU p TnSession: TnSession: responds responds to T to Telnet elnet session session (Telnet Session) Disab D

Summary of the content on the page No. 14

Table 6. Alarm Configuration Options Option Factory 1 Factory 2 Comments/Description Disab Disab Does not display alarm messages. Sends alarm messages to Modem Modem Modem port. Al Alrm Msg: M Sends alarm messages to COM Com Com port. Sends alarm messages to both Both Both ports. Enab Enab SNMP SNMP T Trap: rap: Sends Sends SNMP traps. SNMP traps Disab Disab Enab Enab Specifies whether the modem p T TrapDisc: rapDisc: connection will disconnect after a connection will disconnect after a Disab

Summary of the content on the page No. 15

Table 7. Management – General Configuration Options (1 of 2) Option Factory 1 Factory 2 Comments/Description Disab Disab Specifies whether the DSU/CSU p SNMP SNMP Mgt: Mgt: responds to SNMP session responds to SNMP session Enab Enab requests. Specifies whether the DSU/CSU Disab Disab validates validates the IP address of an the IP address of an NMS V NMS Valid: alid: SNMP manager attempting Enab Enab access. The number of management 1 1 Num Sec Mgrs: systems authorized to send SNMP 2–10 2–10 m

Summary of the content on the page No. 16

Table 7. Management – General Configuration Options (2 of 2) Option Factory 1 Factory 2 Comments/Description Edit Edit The Subnet Mask needed to Com NetMask: Com NetMask: access access the device when the COM the device when the COM Clear Clear port is configured for SNMP. PPP PPP The link layer protocol for the COM The link layer protocol for the COM Com Link: Com Link: port when configured for SNMP. SLIP SLIP Edit Edit Specifies the IP address for the p Modem Modem IP Adr: IP Adr: MODEM MODE

Summary of the content on the page No. 17

Table 8. Management – Trap Configuration Options Option Factory 1 Factory 2 Comments/Description 1 1 The number of trap managers Num Trap Mgrs: 2–6 2–6 supported by the device. Specifies the IP address for each Edit Edit trap trap manager manager. This configuration . This configuration T Trap rapn n IP Adr: IP Adr: option is repeated for all n Clear Clear managers. None None Def Def Trapn Dst: Specifies the network destination Com Com f for T or Trap rap Mana Manager ger n n. . Modem Modem F

Summary of the content on the page No. 18

Notes 16


Alternative user manuals
# User manual Category Download
1 Paradyne 12-Port T1 Access Multiplexer TAM1500-12 User manual Network Card 0
2 Paradyne 12-Port VoSHDSL Access Multiplexer SAM2000GV-12 User manual Network Card 0
3 Paradyne 12-Port SHDSL Access Multiplexer SAM2000G-12 User manual Network Card 0
4 Paradyne 1810 User manual Network Card 0
5 Paradyne 24-Port SHDSL Mini DSLAM SMD2000-24T User manual Network Card 0
6 Paradyne 3160 User manual Network Card 1
7 Paradyne 12-Port VoSHDSL Access Multiplexer SAM2000V-12 User manual Network Card 0
8 Paradyne 3160-A3 User manual Network Card 0
9 Paradyne 3162 User manual Network Card 0
10 Paradyne 3160-A4 User manual Network Card 0
11 Paradyne 12-Port VoSHDSL Access Multiplexer SAM2000QV-12 User manual Network Card 0
12 Paradyne 3161 User manual Network Card 0
13 Paradyne 3161-B3 User manual Network Card 0
14 Paradyne 3162 DSU/CSU User manual Network Card 0
15 Paradyne 3164 User manual Network Card 0
16 Sony BTA-NW1A User manual Network Card 2
17 Sony BKMW-E3000 User manual Network Card 2
18 Sony AC-SQ950D User manual Network Card 0
19 Sony BBV RX100 User manual Network Card 3
20 Sony CLIE A-AVZ-100-11 User manual Network Card 1