Fortinet FortiGate 5140-R user manual

User manual for the device Fortinet FortiGate 5140-R

Device: Fortinet FortiGate 5140-R
Category: Network Card
Manufacturer: Fortinet
Size: 7.35 MB
Added : 3/25/2014
Number of pages: 32
Print the manual

Download

How to use this site?

Our goal is to provide you with a quick access to the content of the user manual for Fortinet FortiGate 5140-R. Using the online preview, you can quickly view the contents and go to the page where you will find the solution to your problem with Fortinet FortiGate 5140-R.

For your convenience

If looking through the Fortinet FortiGate 5140-R user manual directly on this website is not convenient for you, there are two possible solutions:

  • Full Screen Viewing - to easily view the user manual (without downloading it to your computer), you can use full-screen viewing mode. To start viewing the user manual Fortinet FortiGate 5140-R on full screen, use the button Fullscreen.
  • Downloading to your computer - You can also download the user manual Fortinet FortiGate 5140-R to your computer and keep it in your files. However, if you do not want to take up too much of your disk space, you can always download it in the future from ManualsBase.
Fortinet FortiGate 5140-R User manual - Online PDF
Advertisement
« Page 1 of 32 »
Advertisement
Print version

Many people prefer to read the documents not on the screen, but in the printed version. The option to print the manual has also been provided, and you can use it by clicking the link above - Print the manual. You do not have to print the entire manual Fortinet FortiGate 5140-R but the selected pages only. paper.

Summaries

Below you will find previews of the content of the user manuals presented on the following pages to Fortinet FortiGate 5140-R. If you want to quickly view the content of pages found on the following pages of the manual, you can use them.

Abstracts of contents
Summary of the content on the page No. 1

5000SM 5000SM
10/100 10/100
link/Act link/Act
10/100 10/100
link/Act link/Act
FortiGate-5140-R
Chassis Guide
5140SAP SERIAL 1 SERIAL 2 ALARM
5140
13 11 975312468 10 12 14
ETH0 ETH1
ETH0
Service
RESET
STATUS
Hot Swap
12
ETH0 ETH1
ETH0
Service
RESET
STATUS
Hot Swap
FILTER
0 FAN TRAY 12 FAN TRAY FAN TRAY
A detailed guide to the FortiGate-5140 chassis. This FortiGate-5140-R Chassis Guide describes FortiGate-5140
hardware features, and how to install the FortiGate-5140 chassis.
The most recent versi

Summary of the content on the page No. 2

Warnings and cautions Warnings and cautions Only trained and qualified personnel should be allowed to install or maintain FortiGate-5000 series equipment. Read and comply with all warnings, cautions and notices in this document. CAUTION: Risk of Explosion if Battery is replaced by an Incorrect Type. Dispose of Used Batteries According to the Instructions. Caution: You should be aware of the following cautions and warnings before installing FortiGate-5000 series hardware • Turning off all pow

Summary of the content on the page No. 3

Contents Contents Warnings and cautions................................................................................................... 2 FortiGate-5140 chassis............................................................................ 5 FortiGate-5140 chassis front panel ............................................................................... 6 FortiGate-5140 chassis back panel ............................................................................... 7 Physical description of

Summary of the content on the page No. 4

Contents For more information............................................................................. 31 Fortinet documentation ................................................................................................ 31 Fortinet Tools and Documentation CD ..................................................................... 31 Fortinet Knowledge Center ...................................................................................... 31 Comments on Fortinet technical documentati

Summary of the content on the page No. 5

FortiGate-5140 chassis FortiGate-5140 chassis You can install up to 14 FortiGate-5000 series boards in the 14 front panel slots of the FortiGate-5140 ATCA chassis. The FortiGate-5140 is a 12U chassis that contains two redundant hot swappable DC power entry modules that connect to -48 VDC Data Center DC power. The FortiGate-5140 chassis also includes three hot swappable cooling fan trays and a front accessible air filter. If all 14 front panel slots contain FortiGate-5005A2, FortiGate-5001S

Summary of the content on the page No. 6

5000SM 5000SM 10/100 10/100 link/Act link/Act 10/100 10/100 link/Act link/Act FortiGate-5140 chassis front panel FortiGate-5140 chassis FortiGate-5140 chassis front panel Figure 1 shows the front panel of a FortiGate-5140 chassis. Two FortiSwitch-5003A boards are installed in slots 1 and 2. Twelve FortiGate-5001A-DW boards installed in slots 3 to 14. Figure 1: FortiGate-5140 chassis front panel with FortiGate-5001A-DW and FortiSwitch-5003A boards installed FortiGate-5001A-DW FortiGate-5001A-D

Summary of the content on the page No. 7

FortiGate-5140 chassis FortiGate-5140 chassis back panel Also visible on the front of the FortiGate-5140 chassis: • Electrostatic discharge (ESD) socket, used for connecting an ESD wrist or ankle band when working with the chassis. • Front cable tray, used for managing and securing ethernet and other cables. • Front accessible air filter. • Three hot swappable FortiGate-5140 cooling fan trays. FortiGate-5140 chassis back panel Figure 2 on page 7 shows the back panel of the FortiGate-5140 chassi

Summary of the content on the page No. 8

Physical description of the FortiGate-5140 chassis FortiGate-5140 chassis For detailed information about connecting power to the FortiGate-5140 chassis, see “Connecting a FortiGate-5140 chassis to data center DC power and data center ground” on page 17 or “Connecting the FortiGate-5140 chassis to AC power using the FortiGate-5053 power converter tray” on page 20. The power entry modules are hot swappable, which means you can remove and replace a defective PEM while the FortiGate-5140 is oper

Summary of the content on the page No. 9

FortiGate-5140 chassis FortiGate-5140 shelf managers The FortiGate-5140 shelf managers control chassis power up and power down, chassis power distribution, monitor chassis operating parameters, monitor and control chassis cooling, and can signal alarms if the chassis encounters problems. All FortiGate-5000 modules installed in the chassis communicate with the shelf managers. The FortiGate-5140 shelf managers are factory installed. In most cases users do not have to install or configure the s

Summary of the content on the page No. 10

FortiGate-5140 shelf alarm panel FortiGate-5140 chassis Shelf Manager fan and power control The FortiGate-5140 shelf managers monitor the internal temperature of the FortiGate-5140 chassis and adjust the operating speed of the FortiGate-5140 chassis cooling fans as required. When the chassis is first powered on all cooling fans run at full speed. Once the shelf manager is up and running, the shelf manager reduces cooling fan speeds to maintain an optimum temperature in the chassis. If shelf

Summary of the content on the page No. 11

FortiGate-5140 chassis FortiGate-5140 shelf alarm panel Table 4: FortiGate-5140 shelf alarm panel connectors Connector Type Speed Protocol Description SERIAL 1 RJ-45 9600 bps, RS-232 Serial connection to the primary shelf manager 8/N/1 serial command line interface. SERIAL 2 RJ-45 9600 bps, RS-232 Serial connection to the secondary shelf 8/N/1 serial manager command line interface. ALARM micro N/A Telco The external dry relay Telco alarm interface DB-15 Form-c (48VDC) provides Telco form-c re

Summary of the content on the page No. 12

Shelf manager command line interface (CLI) FortiGate-5140 chassis Figure 6: The telco alarm connector (DB-15 male) 15 9 8 1 Table 5: Telco alarm connector pin assignment Pin Name Description 1 AMIR+ MinorReset+ 2 AMIR- MinorReset- 3 AMAR+ MajorReset+ 4 AMAR- MajorReset- 5 ACNO CriticalAlarm - NO 6 ACNC CriticalAlarm - NC 7 ACCOM CriticalAlarm - COM 8 AMINO MinorAlarm -NO 9 AMINC MinorAlarm - NC 10 AMINCOM MinorAlarm - COM 11 AMANO MajorAlarm - NO 12 AMANC MajorAlarm - NC 13 AMACOM MajorAlarm -

Summary of the content on the page No. 13

FortiGate-5140 chassis Shelf manager command line interface (CLI) Figure 7: Connecting to a shelf manager serial port SERIAL 2 (Secondary Shelf Manager) SERIAL1 (Primary Shelf Manager) FortiGate-5140 Shelf Alarm Panel 5140SAP SERIAL 1 SERIAL 2 ALARM Fortinet RJ-45 to 9-pin Console Cable To PC RS-232 Console Port To connect to the shelf manager CLI using a shelf alarm panel serial port 1 Connect the Fortinet console cable to the shelf alarm panel Serial 1 or Serial 2 port (see Figure 7). 2 Conne

Summary of the content on the page No. 14

Air filter FortiGate-5140 chassis 2 Enter and confirm a new password for the root account. The password should be between 5 and 8 characters long and should include a combination of upper and lower case letters and numbers. You can use the passwd command to change the root account password at any time. You can also use the passwd command to remove the root account. Enter the passwd command and when prompted for a password, press enter to add a blank password. To use the shelf manager command l

Summary of the content on the page No. 15

FortiGate-5140 chassis Cooling fan trays Cooling fan trays The FortiGate-5140 chassis contains three interchangeable hot-swappable cooling fan trays installed at the front bottom of the chassis. You can remove any fan tray by lifting the front cable tray, pressing the hot swap button on the tray front panel, fully loosening the mounting knots, and then pulling the fan tray out using the extraction handle. Each cooling fan tray contains two radial fans for cooling the modules installed in the

Summary of the content on the page No. 16

Cooling fan trays FortiGate-5140 chassis FortiGate-5140-R Chassis Guide 16 01-30000-87705-20090108 http://docs.fortinet.com/ • Feedback

Summary of the content on the page No. 17

Power connection and configuration Power connection and configuration This chapter describes how to connect data center DC power to a FortiGate-5140 chassis. If data center DC power is not available, this document also describes how to use the FortiGate-5053 power convertor tray to supply DC power to the FortiGate-5140 chassis. This chapter describes: • About data center DC power • Connecting a FortiGate-5140 chassis to data center DC power and data center ground • Connecting the FortiGate-514

Summary of the content on the page No. 18

Connecting a FortiGate-5140 chassis to data center DC power and data center ground This section describes: • Connecting a FortiGate-5140 PEM to data center DC power • Connecting the FortiGate-5140 chassis to data center ground Connecting a FortiGate-5140 PEM to data center DC power The following procedure describes how to connect power to PEM A. You can repeat this procedure to connect PEM B. Figure 9: Connecting a FortiGate-5140 PEM to data center DC power Data Center -48VDC connector Data Ce

Summary of the content on the page No. 19

Power connection and configuration To connect a FortiGate-5140 PEM to data center DC power 1 Attach the ESD wrist strap to your wrist and to an ESD socket or to a bare metal surface on the chassis or frame. 2 Loosen the screws and remove the terminal block cover from the FortiGate-5140 PEM. 3 Connect the DC power wires (see Figure 9): • Connect a black -48V power wire from the data center DC power source to connector 1 on the FortiGate-5140 PEM terminal strip labeled -48V/-60 VDC nom. • Connec

Summary of the content on the page No. 20

Connecting the FortiGate-5140 chassis to AC power using the FortiGate-5053 power converter tray Figure 10: Connecting a FortiGate-5140 chassis to data center ground Chassis FortiGate-5140 ground Ground connector connector (green) GND Data Center ground connector To connect the FortiGate-5140 chassis to data center ground 1 Attach the ESD wrist strap to your wrist and to an ESD socket or to a bare metal surface on the chassis or frame. 2 Connect the green ground wire from the data center ground


Alternative user manuals
# User manual Category Download
1 Fortinet FortiAnalyzer 1000B User manual Network Card 79
2 Fortinet FortiAnalyzer FortiDB-400B User manual Network Card 29
3 Fortinet FortiDB-1000B User manual Network Card 8
4 Fortinet FortiAnalyzer 3.0 MR7 User manual Network Card 17
5 Fortinet FortiDB-2000B User manual Network Card 10
6 Fortinet FortiBridge 2002F User manual Network Card 2
7 Fortinet FortiGate 1000A-LENC User manual Network Card 8
8 Fortinet FortiGate 224B User manual Network Card 36
9 Fortinet FortiBridge 1000 User manual Network Card 4
10 Fortinet FortiGate 300 User manual Network Card 65
11 Fortinet FortiGate 3000 User manual Network Card 9
12 Fortinet FortiGate 100 User manual Network Card 1532
13 Fortinet FortiGate 3016B User manual Network Card 3
14 Fortinet FortiGate 110C User manual Network Card 573
15 Fortinet FortiGate 310B-LENC User manual Network Card 10
16 Sony BTA-NW1A User manual Network Card 2
17 Sony BKMW-E3000 User manual Network Card 2
18 Sony AC-SQ950D User manual Network Card 0
19 Sony BBV RX100 User manual Network Card 3
20 Sony CLIE A-AVZ-100-11 User manual Network Card 1