Summary of the content on the page No. 1
SmartSwitch 9000
9F120-08 / 9F122-12 / 9F125-08
Local Management Appendix
9031372-01
Summary of the content on the page No. 2
Summary of the content on the page No. 3
Appendix 9F120-08 / 9F122-12 / 9F125-08 Module Specific Information Introduction This appendix contains local management information that is specific to the 9F120-08, 9F122-12 and 9F125-08 MicroLAN modules. Default Interface Codes The Default Interface field on the General Configuration Screen allows you to enter a number (one through three). Each number represents a default interface for the selected module. The table below lists the numbers you can enter, each number’s correspondin
Summary of the content on the page No. 4
9F120-08 / 9F122-12 / 9F125-08 Module Specific Information FNB Resource Configuration Codes All of the MicroLAN Modules described in this appendix physically attach to the FNB-1 and the FNB-2 on the SmartSwitch 9000 backplane. By default, the module inserts into four rings (the primary and secondary rings of the FNB-1 and the FNB-2). The FNB Resource Configuration Screen allows you to customize this configuration to your particular needs. The FNB Resource Configuration Screen allows you to:
Summary of the content on the page No. 5
9F120-08 / 9F122-12 / 9F125-08 Module Specific Information Table 2. 9F12x-xx MicroLAN Module FNB Resource Configuration Codes Configuration FDDI Connections Description ID The module is attached, but not inserted, to 1 FNB 1 Pri. (MAC) Byp. , the primary ring on the FNB-1. The module is FNB 2 Pri. (No MAC) Byp. attached, but not inserted, to the primary ring on the FNB-2. The MAC resides on FNB-1. The module is attached to the FNB-1 primary ring and the FNB-2 primary ring. The switch 2
Summary of the content on the page No. 6
9F120-08 / 9F122-12 / 9F125-08 Module Specific Information Table 2. 9F12x-xx MicroLAN Module FNB Resource Configuration Codes (Continued) Configuration FDDI Connections Description ID The module is attached to the FNB-1 primary ring and the FNB-2 primary ring. The switch 7 FNB 1 Pri. (No MAC) Ins. , that inserts the module into the FNB-1 is FNB 2 Pri. (MAC) Byp. turned on. The switch that inserts the module into the FNB-2 is turned off. The MAC resides on FNB-2. The module is attached to
Summary of the content on the page No. 7
9F120-08 / 9F122-12 / 9F125-08 Module Specific Information Table 2. 9F12x-xx MicroLAN Module FNB Resource Configuration Codes (Continued) Configuration FDDI Connections Description ID The module is attached to the FNB-1 primary ring and the FNB-2 secondary ring. The 13 FNB 1 Pri. (No MAC) Byp. , switch that inserts the module into the FNB-1 FNB 2 Sec. (MAC) Byp. is turned off. The switch that inserts the module into the FNB-2 is turned off. The MAC resides on FNB-2. The module is attache
Summary of the content on the page No. 8
9F120-08 / 9F122-12 / 9F125-08 Module Specific Information Table 2. 9F12x-xx MicroLAN Module FNB Resource Configuration Codes (Continued) Configuration FDDI Connections Description ID The module is attached to the FNB-1 secondary ring and the FNB-2 primary ring. 19 FNB 1 Sec. (MAC) Ins. , The switch that inserts the module into the FNB 2 Pri. (No MAC) Byp. FNB-1 is turned on. The switch that inserts the module into the FNB-2 is turned off. The MAC resides on FNB-1. The module is attached
Summary of the content on the page No. 9
9F120-08 / 9F122-12 / 9F125-08 Module Specific Information Table 2. 9F12x-xx MicroLAN Module FNB Resource Configuration Codes (Continued) Configuration FDDI Connections Description ID The module is attached to the FNB-1 secondary ring and the FNB-2 secondary ring. 25 FNB 1 Sec. (MAC) Byp. , The switch that inserts the module into the FNB 2 Sec. (No MAC) Byp. FNB-1 is turned off. The switch that inserts the module into the FNB-2 is turned off. The MAC resides on FNB-1. The module is attac
Summary of the content on the page No. 10
9F120-08 / 9F122-12 / 9F125-08 Module Specific Information Table 2. 9F12x-xx MicroLAN Module FNB Resource Configuration Codes (Continued) Configuration FDDI Connections Description ID The module is attached to the FNB-1 secondary ring and the FNB-2 secondary ring. 31 FNB 1 Sec. (No MAC) Ins. , The switch that inserts the module into the FNB 2 Sec. (MAC) Byp. FNB-1 is turned on. The switch that inserts the module into the FNB-2 is turned off. The MAC resides on FNB-2. The module is attach
Summary of the content on the page No. 11
9F120-08 / 9F122-12 / 9F125-08 Module Specific Information Module Specific Configuration Screen In the FNB Resource Configuration Screen, you determine which of the two FNB rings contains the MAC. The 9F120 MicroLAN Module Specific Configuration Screen allows you to assign one of the two FNB rings (either the ring that contains the MAC or the ring that does not contain the MAC) to each of the module’s M- ports. The default ring that is assigned to each of the module’s M-por
Summary of the content on the page No. 12
9F120-08 / 9F122-12 / 9F125-08 Module Specific Information 10