Transition Networks SSDTF1022-105 user manual

User manual for the device Transition Networks SSDTF1022-105

Device: Transition Networks SSDTF1022-105
Category: Network Card
Manufacturer: Transition Networks
Size: 0.73 MB
Added : 7/7/2014
Number of pages: 9
Print the manual

Download

How to use this site?

Our goal is to provide you with a quick access to the content of the user manual for Transition Networks SSDTF1022-105. Using the online preview, you can quickly view the contents and go to the page where you will find the solution to your problem with Transition Networks SSDTF1022-105.

For your convenience

If looking through the Transition Networks SSDTF1022-105 user manual directly on this website is not convenient for you, there are two possible solutions:

  • Full Screen Viewing - to easily view the user manual (without downloading it to your computer), you can use full-screen viewing mode. To start viewing the user manual Transition Networks SSDTF1022-105 on full screen, use the button Fullscreen.
  • Downloading to your computer - You can also download the user manual Transition Networks SSDTF1022-105 to your computer and keep it in your files. However, if you do not want to take up too much of your disk space, you can always download it in the future from ManualsBase.
Transition Networks SSDTF1022-105 User manual - Online PDF
Advertisement
« Page 1 of 9 »
Advertisement
Print version

Many people prefer to read the documents not on the screen, but in the printed version. The option to print the manual has also been provided, and you can use it by clicking the link above - Print the manual. You do not have to print the entire manual Transition Networks SSDTF1022-105 but the selected pages only. paper.

Summaries

Below you will find previews of the content of the user manuals presented on the following pages to Transition Networks SSDTF1022-105. If you want to quickly view the content of pages found on the following pages of the manual, you can use them.

Abstracts of contents
Summary of the content on the page No. 1

User’s Guide
SSDTF10xx-10x
Stand-Alone Devices
• T1 / E1 with Remote Management
• Copper to Fiber
Transition Networks SSDTF10xx-10x series
Devices encode and decode T1 or E1 twisted-pair
copper signals over fiber optic cable to extend the
distance and transmission reliability of high-speed
T1 or E1 data traffic. The device is framing independent (as ESF vs. D4) and supports all
common line codes (e.g., AMI, B8ZS, HDB3).
The SSDTF10xx-10x is designed to be installed in pairs. For example, instal

Summary of the content on the page No. 2

SSDTF10xx-10x Part Number Port Two - Single Fiber Optic Port One - Copper Installation SSDTF1029-105 ** RJ-45 SC, 1310 mn (TX)/1550 nm (RX) CAUTION: Wear a grounding device and observe electrostatic discharge precautions 1.5 km (5,000 feet) * single mode, 20 km (12.4 miles)* when setting the jumper and switches. Failure to observe this caution could result in SSDTF1029-106 ** RJ-45 SC, 1550 mn (TX)/1310 nm (RX) damage to, and subsequent failure of, the device. 1.5 km (5,000 feet) * single mod

Summary of the content on the page No. 3

SSDTF10xx-10x Installation -- Continued Installation -- Continued 1 Switch 1, Copper -- transmit all ones Set the loop-back switch UP - Disables the transmit all ones Hardware mode: function on the copper interface. The loop-back switch is located on the front panel of the device and is used for Copper - Transmit All Ones - Disabled installation and network debugging procedures. DOWN - Transmits an “all ones” pattern on the copper interface when the signal To set the switch, use a small flat-

Summary of the content on the page No. 4

SSDTF10xx-10x Installation -- Continued Installation -- Continued Settings for T1 configuration (right switch set, SW 1) T1/short-haul signal T1/long-haul signal Use switches 3 and 4 on the left switch set to select T1/short-haul signal (see the drawing below). Use switches 3 and 4 on the left switch set to select T1/long-haul signal (see the drawing below). Use switches 1, 2, and 3 on the right switch set to select the proper network cable settings. The drawing below lists the seven options.

Summary of the content on the page No. 5

SSDTF10xx-10x Installation -- Continued Installation -- Continued Install the copper cable Power the device 1. Locate or build twisted-pair copper cables that are compliant with the Note: The external power supply provided with this product is UL listed by the specifications on page 11 with RJ-45 connectors at both ends. power supply’s manufacturer. 2. Ensure that the MDI/MDI-X switch is set according to the network conditions 1. Install the power adapter cord to the back of the device. (see p

Summary of the content on the page No. 6

SSDTF10xx-10x Cable Specifications Cable Specifications -- Continued Fiber cable Fiber cable SSDTF1027-105 1300 nm multimode Single mode fiber (recommended): 9 µm Fiber Optic Transmitter Power: min: -19.0 dBm max: -10.0 dBm Multimode fiber (recommended): 62.5/125 µm Fiber Optic Receiver Sensitivity: min: -32.5 dBm max: -14.0 dBm Multimode fiber (optional): 100/140, 85/140, 50/125 µm Link Budget: 13.5 dB SSDTF1011-105 850 nm multimode SSDTF1029-105 1310 nm (TX)/1550 nm (RX) simplex Fiber Opt

Summary of the content on the page No. 7

SSDTF10xx-10x Technical Specifications Troubleshooting For use with Transition Networks Model SSDTF10xx-10x or equivalent If the device fails, isolate and correct the failure by determining the answers to the following questions and then taking the indicated action: Standards: Emissions: CISPR A; Telecordia TR-NWT-001089 (designed to meet; NOT tested); FCC Part 68; T1/E1 1. Is the PWR (Power) LED illuminated? Physical layer: ITU-T, ANSI, AT&T, and ETSI; European NO Technical Standard: TBR 12; Br

Summary of the content on the page No. 8

SSDTF10xx-10x 4. Is data transfer failing? Contact Us YES Technical support • Verify the local copper connection by starting a local copper loop-back Technical support is available 24 hours a day: (hardware mode: set the loop-back switch on the local device to “CL”, U.S.A. and Canada: 1-800-260-1312 software mode: enter the local copper loop-back command) and then use a International: 00-1-952-941-7600 bit error test unit to run a bit error test. Transition now Chat live via the Web with Transit

Summary of the content on the page No. 9

SSDTF10xx-10x Compliance Information CISPR22/EN55022 Class A + EN55024 CE Mark FCC regulations This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to part 15 of the FCC rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with


Alternative user manuals
# User manual Category Download
1 Transition Networks CFETF1011-205 User manual Network Card 1
2 Transition Networks E-100BTX-FX-05 User manual Network Card 24
3 Transition Networks CSRFB10XX-100 User manual Network Card 0
4 Transition Networks E-CX-MC02 User manual Network Card 0
5 Transition Networks ETHERNET E- FL/RED-MC01(SMA) User manual Network Card 0
6 Transition Networks ETHERNET E-FL/RED-MC01 User manual Network Card 0
7 Transition Networks CPSMM-120 User manual Network Card 15
8 Transition Networks CPSMC0100-210 User manual Network Card 3
9 Transition Networks N-FX-ST-01 User manual Network Card 0
10 Transition Networks N-FX-SC-01 User manual Network Card 0
11 Transition Networks FAST ETHERNET E-TX-MC01 User manual Network Card 0
12 Transition Networks N-FX-MT-01 User manual Network Card 1
13 Transition Networks N-GXX-XX-01 User manual Network Card 0
14 Transition Networks N-GXX-XX-01(L) User manual Network Card 0
15 Transition Networks POINTSYSTEM CPSMC0800-100 User manual Network Card 0
16 Sony BTA-NW1A User manual Network Card 2
17 Sony BKMW-E3000 User manual Network Card 2
18 Sony AC-SQ950D User manual Network Card 0
19 Sony BBV RX100 User manual Network Card 3
20 Sony CLIE A-AVZ-100-11 User manual Network Card 1