Instruction Manual TOSLINE-S20LP
T2N/T3H stations
REQUIREMENTS
• Keep this instruction manual where it can be easily
referred to by users and those responsible for the
• Read this instruction manual carefully before using
• After this instruction manual has been read, keep it
June, 1998
TOSHIBA CORPORATION
UM-TS02N**-E005
Contents
Main Menu
beside the equipment.
the equipment.
equipment.
Summary of the content on the page No. 2
6 F 3 B 0 3 5 6 © Toshiba Corporation reserves the right to make changes and improvements to this publication and/or related products at any time without notice. No obligation shall be — — Important Information Misuse of this equipment can result in property damage or human injury. Because controlled system applications vary widely, you should satisfy yourself as to the acceptability of this equipment for your intended purpose. In no event will Toshiba Corporation be responsible or liable for ei
Summary of the content on the page No. 3
6 F 3 B 0 3 5 6 Preface The TOSLINE-S20LP is a Local Area Network (LAN) for Factory Automation (FA) system. This manual describes How To Use the TOSLINE-S20LP stations for Programmable Controller • S20LP: • • • STN #n: For details of the programmable controllers T2N, T3H and their programming software T-PDS, ─ 2 ─ refer to the related manuals for these controllers. Station number n TOSLINE-S20LP station for T2N and/or T3H S20LP-station: TOSLINE-S20LP Loader Software S-LS: TOSLINE-S20LP system
Summary of the content on the page No. 4
6 F 3 B 0 3 5 6 Contents PREFACE............................................................................................................................................. 2 CONTENTS.......................................................................................................................................... 3 1. INTRODUCTION TO S20LP ........................................................................................................... 4 1.1 SYSTEM CONFIGURATION................
Summary of the content on the page No. 5
6 F 3 B 0 3 5 6 1. Introduction to S20LP 1.1 System configuration T2N T3H T2N T3H internal bus I/O bus OTR2 OTR1 OTR2 OTR1 Station No.1 Station No.2 S20LP Port SN325 (Main terminal station) (Back-up terminal station) (General station) (General station) (General station) OTR1 OTR2 OTR1 OTR2 OTR1 OTR2 SN325 PTLS9 External Loop T3H PCS Device ─ 4 ─ (Note 1) SBR22 is the long distance repeater for S20LP S-LS (runs on personal computer) Parameter setting tool 1024 words / station Maximum transmissio
Summary of the content on the page No. 6
6 F 3 B 0 3 5 6 1.2 Station hardware • Overview T2N include of S20LP Port PU245N ERUN ET/R EACC Status LEDs for RUN FLT BAT Ethernet Port SRUN SONL SACC Status LEDs for S20LP Port STNH Station number setting switches DIP switches STNL for CPU For S20LP Port LOADER port OTR1 Transmission cable connectors PROG OTR2 10BASE-T For Ethernet Port LINK ─ 5 ─
Summary of the content on the page No. 7
6 F 3 B 0 3 5 6 SN325 SN325 STN ONL SCAN Status LEDs ACC LOOP TX1 TX2 RESET Reset switch STNH Station number setting switches STNL OTR1 Transmission cable connectors OTR2 LOADER LOADER port ─ 6 ─
Summary of the content on the page No. 8
6 F 3 B 0 3 5 6 • Status LEDs: S20LP port for T2N (PU245N) SRUN Lit Station is normal Not lit Down mode SONL Lit Online mode (Scan transmission is executing) Blink Standby mode (Scan transmission is not executing) Not lit Offline mode (Scan transmission is not executing) SACC Lit T2N is accessing the port Not lit T2N is not accessing the port For SN325 STN Lit Station is normal Not lit Down mode ONL Lit Online mode (Scan transmission is executing) Blink Standby mode (Scan transmission is not exe
Summary of the content on the page No. 9
6 F 3 B 0 3 5 6 • Station number setting switches: STNH ................ 10 ’ 1 ’ • Loader port: T2N (PU24 “ ON ” . • Transmission cable connector(s): • Reset switch (only SN325): ─ 8 ─ Used to reset a SN325. Used to connect optical fiber cables. (see Section 4) 5N) changes DIP switch (P/S) Used to connect the S-LS (or T-PDS for remote programming / monitoring). s digit STNL ................ s digit The setting status is read at power-on. tion number. (allowable setting is 1 to 64) Used to se
Summary of the content on the page No. 10
6 F 3 B 0 3 5 6 1.3 S-LS overview The S-LS (TOSLINE-S20 Loader System) on a personal computer (PC) monitors station conditions, reads/writes control data, and sets up parameters. The transmission parameters set by Connection between S-LS and S20LP-station is made by an loader cable, that is the same cable The following are the details of the menu. Select an intended station in the Station Connection ’ [Exit] [Data Access] [Online Map] [Loop Map] [Station Status] Disp [Test Request] [Normal] [Di
Summary of the content on the page No. 11
6 F 3 B 0 3 5 6 The toolbar has buttons for the functions frequently used. The following buttons are found from [Exit button] [Data Access button] ─ ─ 10 Displays the Test Request window. [Test Request button] Displays the Online/Standby Request window. [Online/Standby Request button] Displays the RAS Information Menu window. [RAS Information button] e Data Access window. Displays th Displays the Setup Information window. [Setting Information button] Exits the application. left to right.
Summary of the content on the page No. 12
6 F 3 B 0 3 5 6 1.4 Specifications S20LP system specifications Transmission cable Silica glass SI 200/230μm H-PCF (Hard-Plastic Clad Fiber) Cable connection F07 connector (cable side connector) (JIS C5976) Transmission distance Max. 1 km (between stations) Max. 4 km (between stations ; connecting SBR22) Max. 30 km (system total) Topology Loop Number of stations Max. 64 stations Transmission speed 2 Mbps Transmission code Differential Manchester Modulation method Baseband Communication service (1
Summary of the content on the page No. 13
6 F 3 B 0 3 5 6 2. Scan transmission overview In the S20LP, data sending station is rotated cyclically. Each station has common memory for Scan transmission. The size of the common memory is 4096 words. When a station becomes the data sender station, it sends data of prespecified area of the common memory. All other stations receive the data, and store them into their common memory. Therefore, the common memory in The common memory is allocated to the Link register (W) in the T2N/T3H. The size o
Summary of the content on the page No. 14
6 F 3 B 0 3 5 6 Main terminal station, back-up terminal station and general station When power is applied to each S20LP-station, one station must have station address number 1. The station of station number 1 becomes the main terminal station. The station of station the general stations. The main terminal station controls total timing of the S20LP network. If main terminal station is down, back-up terminal station (station number 2) becomes main terminal station on condition that the back-up ena
Summary of the content on the page No. 15
6 F 3 B 0 3 5 6 3. Setting for data linkage 3.1 Station number setting Each station should have unique station number. If a station number is duplicated, the S20LP network cannot be established. Allowable station number is 1 to 64. To set the station number, two rotary switches (STNH and STNL) are provided on each station. STNH is for 10's digit STNH = 1 3.2 Settings on T-PDS < > ─ ─ 14 A: I/O Allocation A: I/O Allocation P: PLC T-PDS screen example 1 Allocate the S20LP-station as "TL-S". I/O a
Summary of the content on the page No. 16
6 F 3 B 0 3 5 6 a) T2N/T3H W registers 0 100 Send 230 . . . 2047 ─ ─ 15 LINK W1983-2047 Block 32 Receive W256-319 Block 5 LINK W192-255 Block 4 LINK W128-191 Block 3 LINK W064-127 Block 2 LINK W000-063 Receive Block 1 common memory assignment S20LP-station Network Set "LINK" for the Blocks to be assigned. Network assignment (2)
Summary of the content on the page No. 17
6 F 3 B 0 3 5 6 < > ─ ─ 16 N: Network Assignment A: I/O Allocation P: PLC T-PDS screen example 2
Summary of the content on the page No. 18
6 F 3 B 0 3 5 6 b) If two S20LP-stations are mounted on the T3H, the station which is allocated closer to the CPU in the I/O allocation (see (1)) is assigned as CH1. And the other is assigned as CH2. CH1 CH1 CH2 CH2 T3H W registers Send Send . . . . ─ ─ 17 Block 32 LINK Receive Block 6 LINK Block 5 Receive LINK Block 4 LINK Block 3 LINK Block 2 LINK Receive Block 1 LINK assignment common memory common memory assignment Network S20LP-station S20LP-station Network (CH2 is inv
Summary of the content on the page No. 19
6 F 3 B 0 3 5 6 ─ ─ 18