TDK Veta iHA48040A033V* user manual

User manual for the device TDK Veta iHA48040A033V*

Device: TDK Veta iHA48040A033V*
Category: Network Card
Manufacturer: TDK
Size: 0.33 MB
Added : 9/19/2013
Number of pages: 17
Print the manual

Download

How to use this site?

Our goal is to provide you with a quick access to the content of the user manual for TDK Veta iHA48040A033V*. Using the online preview, you can quickly view the contents and go to the page where you will find the solution to your problem with TDK Veta iHA48040A033V*.

For your convenience

If looking through the TDK Veta iHA48040A033V* user manual directly on this website is not convenient for you, there are two possible solutions:

  • Full Screen Viewing - to easily view the user manual (without downloading it to your computer), you can use full-screen viewing mode. To start viewing the user manual TDK Veta iHA48040A033V* on full screen, use the button Fullscreen.
  • Downloading to your computer - You can also download the user manual TDK Veta iHA48040A033V* to your computer and keep it in your files. However, if you do not want to take up too much of your disk space, you can always download it in the future from ManualsBase.
TDK Veta iHA48040A033V* User manual - Online PDF
Advertisement
« Page 1 of 17 »
Advertisement
Print version

Many people prefer to read the documents not on the screen, but in the printed version. The option to print the manual has also been provided, and you can use it by clicking the link above - Print the manual. You do not have to print the entire manual TDK Veta iHA48040A033V* but the selected pages only. paper.

Summaries

Below you will find previews of the content of the user manuals presented on the following pages to TDK Veta iHA48040A033V*. If you want to quickly view the content of pages found on the following pages of the manual, you can use them.

Abstracts of contents
Summary of the content on the page No. 1


®
Data Sheet: Veta iHA48040A033V*, 3.3V/40A Output Half Brick Series











Datasheet DC-DC Power Modules
Ò
Veta iHA48040A033V* Half Brick Series
48V Input, 3.3V/40A.Output















TDK Innoveta Inc

3320 Matrix Drive, Suite 100

Richardson, Texas 75082
Information furnished by TDK Innoveta is believed to be accurate and reliable. However, TDK

Innoveta assumes no responsibility for its use, nor for any infringement of patents or other ri

Summary of the content on the page No. 2

® Data Sheet: Veta iHA48040A033V*, 3.3V/40A Output Half Brick Series Platform Overview: Ò Veta iHA48 Series DC-DC Power Modules 48V Input, 1.2-28V/60A or 350W Output Half-Brick ® The Veta iHA48 Series power modules operate over a wide 36 – 75Vdc input voltage range and provide one regulated dc output voltage that is electrically isolated from the input. Its high efficiency and superior thermal performance make ® the Veta Family of power modules ideally suited for

Summary of the content on the page No. 3

® Data Sheet: Veta iHA48040A033V*, 3.3V/40A Output Half Brick Series Ordering information: Output Main Product Input Output # of Safety Package Size Platform Current/ Output Feature Set Identifier Voltage Units Outputs Class Power Voltage i H A 48 060 A 033 V - 0 00 00 – Standard ® TDK Innoveta Half Brick Veta 36-75V 60 Amps 033 – 3.3V Single Feature On/Off Omit Threaded Pin Output OVP Output OCP OTP Set Logic pin3 Inserts Length 00 Positive No Latching Auto-Re

Summary of the content on the page No. 4

® Data Sheet: Veta iHA48040A033V*, 3.3V/40A Output Half Brick Series Mechanical Specification: Unless otherwise specified tolerances are: x.x ± 0.5 mm [x.xx ± 0.02 in.], x.xx +/- 0.25 mm [x.xxx +/- 0.010 in.] Recommended Hole Pattern: (top view) Pin Assignment: PIN FUNCTION PIN FUNCTION 1 Vin (+) 7 Trim 2 On/Off 8 Sense (+) 3 Case (Omit – optional) 9 Vout (+) 4 Vin (-) 5 Vout (-) 6 Sense (-) ' (877) 498-0099 ©2007 TDK Innoveta Inc. 4/17 iHA D

Summary of the content on the page No. 5

® Data Sheet: Veta iHA48040A033V*, 3.3V/40A Output Half Brick Series Absolute Maximum Ratings: Stress in excess of Absolute Maximum Ratings may cause permanent damage to the device. Characteristic Min Max Unit Notes & Conditions Continuous Input Voltage -0.5 80 Vdc Transient Input Voltage --- 100 Vdc 100mS max. Isolation Voltage --- 1500 Vdc Storage Temperature -55 125 °C Maximum base plate temperature. Measured at the Operating Temperature Range (Tc) -40 115* °C locati

Summary of the content on the page No. 6

® Data Sheet: Veta iHA48040A033V*, 3.3V/40A Output Half Brick Series Electrical Data (continued): Operating at Tc = 25°C unless otherwise specified Output Characteristic Min Typ Max Unit Notes & Conditions Output Voltage Initial Setpoint 3.25 3.3 3.35 Vdc Vin=Vin,nom; Io=Io,max; Output Voltage Tolerance 3.2 --- 3.4 Vdc Over all rated input voltage, load, and temperature conditions to end of life Efficiency --- 91.5 --- % Vin=Vin,nom; Io=Io,max; Line Regulation ---

Summary of the content on the page No. 7

® Data Sheet: Veta iHA48040A033V*, 3.3V/40A Output Half Brick Series Electrical Characteristics: iHA48040A033V-001 Efficiency iHA48040A033V-001 Power Dissipation Ta = 25 Deg C. Ta = 25 Deg C. 95 14 12 90 10 85 8 6 80 4 75 2 70 0 0 4 8 12 16 20 24 28 32 36 40 0 4 8 12 16 20 24 28 32 36 40 Output Current (A) Output Current (A) Vin = 36V Vin = 48V Vin = 75V Vin = 36V Vin = 48V Vin = 75V iHA48040A033V-001 Typical Efficiency vs. Output iHA48040A033V-001 Typical Power Dissipation vs

Summary of the content on the page No. 8

® Data Sheet: Veta iHA48040A033V*, 3.3V/40A Output Half Brick Series Electrical Characteristics (continued): iHA48040A033V-001 Current Limit Ta = 25 Deg C. 4 3 2 1 0 5 10 15 20 25 30 35 40 45 50 Output Current (A) Vin = 36V Vin = 48V Vin = 75V iHA48040A033V-001 Typical Output Current Limit iHA48040A033V-001 Typical Output Ripple at nominal Characteristics vs. Input Voltage at Ta=25 degrees. Input voltage and full load with external capacitors 47uF+1uF+0.1uF at Ta=25 degree

Summary of the content on the page No. 9

® Data Sheet: Veta iHA48040A033V*, 3.3V/40A Output Half Brick Series Electrical Characteristics (continued): 1000 10000 100 1000 10 100 1 0 10 0 10 20 30 40 0 2 4 6 8 10 % Decrease in Output Voltage, (%) % Increase in Output Voltage, (%) Δ Δ iHA48040A033V-001 Trim down curve for output iHA48040A033V-001 Trim up curve for output voltage voltage adjustment adjustment ' (877) 498-0099 ©2007 TDK Innoveta Inc. 9/17 iHA Datasheet 040207 T rim R esistance (k )

Summary of the content on the page No. 10

® Data Sheet: Veta iHA48040A033V*, 3.3V/40A Output Half Brick Series Thermal Performance: 40 30 20 10 25 35 45 55 65 75 85 95 105 115 o Ambient Temperature ( C) NC 0.3 m/s (60 LFM) 0.5 m/s (100 LFM) 1.0 m/s (200 LFM) 1.5 m/s (300 LFM) IMS LIMIT iHA48040A033V-001 maximum output current vs. ambient temperature at nominal input voltage for airflow rates natural convection 0.3 m/s (60lfm) to 3.0m/s (600lfm) with airflow from output to input. 5.0 40 4.5 4.0 3.5 30 3.0 2.5 20

Summary of the content on the page No. 11

® Data Sheet: Veta iHA48040A033V*, 3.3V/40A Output Half Brick Series Thermal Performance (continued): 40 40 35 35 30 30 25 25 20 20 15 15 10 10 5 5 0 0 107 108 109 110 111 112 113 114 105 106 107 108 109 o o Temperature ( C) Temperature ( C) 1/4" HS 1/2" HS 1" HS 1/4" HS 1/2" HS 1" HS iHA48040A033V-001 with heatsink maximum Output iHA48040A033V-001 with heatsink maximum Output Current Current vs. maximum allowable IMS Temperature at vs. maximum allowable IMS Temperature at n

Summary of the content on the page No. 12

® Data Sheet: Veta iHA48040A033V*, 3.3V/40A Output Half Brick Series top of the module and a parallel facing PCB Thermal Management: kept at a constant (0.5 in). The power module’s orientation with respect to the An important part of the overall system airflow direction can have a significant design process is thermal management; impact on the unit’s thermal performance. thermal design must be considered at all levels to ensure good reliability and lifetime of the fi

Summary of the content on the page No. 13

® Data Sheet: Veta iHA48040A033V*, 3.3V/40A Output Half Brick Series Heat transfer by convection can be Standard heatsink kits are available from enhanced by increasing the airflow rate that TDK Innoveta for vertical module mounting the power module experiences. The in two different orientations (longitudinal – maximum output current of the power perpendicular to the direction of the pins and module is a function of ambient temperature transverse – parallel to the direction of th

Summary of the content on the page No. 14

® Data Sheet: Veta iHA48040A033V*, 3.3V/40A Output Half Brick Series It is recommended that the power module be Operating Information: kept off for at least 100mS each time it is turned off. Over-Current Protection: The power The standard on/off logic is positive logic. The modules have current limit protection to power module will turn on if terminal 2 is left protect the module during output overload and open and will be off if terminal 2 is connected short circuit c

Summary of the content on the page No. 15

® Data Sheet: Veta iHA48040A033V*, 3.3V/40A Output Half Brick Series percentage of Vout (%Vo) from Vo,nom, the trimmed up, the maximum output current must trim resistor should be chosen according to be decreased to maintain the maximum rated the following equation: power of the module. 100% R = ( - 2) kΩ As the output voltage is trimmed, the output down Δ down over-voltage set point is not adjusted. where Trimming the output voltage too high may cause the output over volta

Summary of the content on the page No. 16

® Data Sheet: Veta iHA48040A033V*, 3.3V/40A Output Half Brick Series Input/Output Ripple and Noise Measurements: 12uH 1 2 Battery + + RLoad Cext Cin 33uF Vinput Voutput 220uF esr<0.1 esr<0.7 100KHz 100KHz - - Ground Plane The input reflected ripple is measured with a current probe and oscilloscope. The ripple current is the current through the 12uH inductor. The capacitor Cin shall be at least 100uF/100V. One 470uF or two 220uF/100V capacitors in parallel are recommended.

Summary of the content on the page No. 17

® Data Sheet: Veta iHA48040A033V*, 3.3V/40A Output Half Brick Series than 2M hours using the Telcordia TR-332 are assembled at ISO certified assembly calculation method. plants. Improper handling or cleaning processes can Warranty: adversely affect the appearance, testability, and reliability of the power modules. Contact TDK Innoveta’s comprehensive line of power TDK Innoveta technical support for guidance solutions includes efficient, high-density DC- regarding proper


Alternative user manuals
# User manual Category Download
1 TDK CF Series CF61A700 User manual Network Card 0
2 TDK DEA Series DEA200710LT-1238A1 User manual Network Card 4
3 TDK DEA Series DEA162500LT-1217A1 User manual Network Card 0
4 TDK DEA Series DEA202495BT-1242B2 User manual Network Card 2
5 TDK DEA Series DEA205375BT-2054A1 User manual Network Card 0
6 TDK DEA Series DEA252450BT-7012D1 User manual Network Card 0
7 TDK Belleta iEA Series User manual Network Card 0
8 TDK Belleta iPB Series User manual Network Card 0
9 TDK DEA Series DEA201990LT-9003D1 User manual Network Card 1
10 TDK DEA Series DEA162450BT-1260B2 User manual Network Card 0
11 TDK DEA Series User manual Network Card 0
12 TDK Ceramic Capacitors FD Series User manual Network Card 0
13 TDK DEA Series DEA165850LT-1197B2 User manual Network Card 1
14 TDK DEA Series DEA255395BT-2065D2 User manual Network Card 1
15 TDK CU Series User manual Network Card 6
16 Sony BTA-NW1A User manual Network Card 2
17 Sony BKMW-E3000 User manual Network Card 2
18 Sony AC-SQ950D User manual Network Card 0
19 Sony BBV RX100 User manual Network Card 3
20 Sony CLIE A-AVZ-100-11 User manual Network Card 1