Siemens 200 user manual

User manual for the device Siemens 200

Device: Siemens 200
Category: Network Card
Manufacturer: Siemens
Size: 3.19 MB
Added : 5/1/2014
Number of pages: 282
Print the manual

Download

How to use this site?

Our goal is to provide you with a quick access to the content of the user manual for Siemens 200. Using the online preview, you can quickly view the contents and go to the page where you will find the solution to your problem with Siemens 200.

For your convenience

If looking through the Siemens 200 user manual directly on this website is not convenient for you, there are two possible solutions:

  • Full Screen Viewing - to easily view the user manual (without downloading it to your computer), you can use full-screen viewing mode. To start viewing the user manual Siemens 200 on full screen, use the button Fullscreen.
  • Downloading to your computer - You can also download the user manual Siemens 200 to your computer and keep it in your files. However, if you do not want to take up too much of your disk space, you can always download it in the future from ManualsBase.
Siemens 200 User manual - Online PDF
Advertisement
« Page 1 of 282 »
Advertisement
Print version

Many people prefer to read the documents not on the screen, but in the printed version. The option to print the manual has also been provided, and you can use it by clicking the link above - Print the manual. You do not have to print the entire manual Siemens 200 but the selected pages only. paper.

Summaries

Below you will find previews of the content of the user manuals presented on the following pages to Siemens 200. If you want to quickly view the content of pages found on the following pages of the manual, you can use them.

Abstracts of contents
Summary of the content on the page No. 1

Instruction Manual July 2009
multiranger
100/200

Summary of the content on the page No. 2

Safety Guidelines: Warning notices must be observed to ensure personal safety as well as that of others, and to protect the product and the connected equipment. These warning notices are accompanied by a clarification of the level of caution to be observed. Qualified Personnel: This device/system may only be set up and operated in conjunction with this manual. Qualified personnel are only authorized to install and operate this equipment in accordance with established safety practices an

Summary of the content on the page No. 3

mmmmm Table of Contents Table of Contents The MultiRanger 100 and 200 ...............................................................................................................1 MultiRanger 100 ............................................................................................................................1 MultiRanger 200 ............................................................................................................................1 The Manual ......................

Summary of the content on the page No. 4

Hand Programmer .......................................................................................................................27 Programmer Keys ........................................................................................................................28 Dolphin Plus ............................................................................................................................................29 Dolphin Plus Toolbar Buttons ......................................

Summary of the content on the page No. 5

mmmmm Table of Contents mA I/O ..............................................................................................................................................................49 mA Input [MR 200] ................................................................................................................................49 mA Output ...............................................................................................................................................49 Vol

Summary of the content on the page No. 6

Setting the Common Parameters ............................................................................................70 Set Relay 1 (Operate Rake) .......................................................................................................70 Set Relays 2 to 4 (Level Alarms) ..............................................................................................70 External Totalizers and Flow Samplers [MR 200] .................................................................

Summary of the content on the page No. 7

mmmmm Table of Contents Communications Installation .............................................................................................................92 Wiring Guidelines ..................................................................................................................................92 Ports 1 and 2 .................................................................................................................................92 Ports 1 and 2: RS-232 RJ-11 Jack and RS

Summary of the content on the page No. 8

Error Handling ......................................................................................................................................111 Communication Troubleshooting ...................................................................................................113 Generally ...............................................................................................................................................113 Specifically ............................................

Summary of the content on the page No. 9

mmmmm Table of Contents Temperature Compensation (P660 to P664) ..................................................................................181 Rate (P700 to P708) ............................................................................................................................183 Measurement Verification (P710 to P713) ....................................................................................187 Transducer Scanning (P726 to P729) ....................................

Summary of the content on the page No. 10

Obstructions in the Sound Beam ......................................................................................... 235 Nozzle Mountings .................................................................................................................... 235 Set the MultiRanger to Ignore the Bad Echo .................................................................... 236 Wrong Reading ...........................................................................................................

Summary of the content on the page No. 11

mmmmm MultiRanger 100/200 The MultiRanger 100 and 200 The MultiRanger is available in two models, MultiRanger 100 and MultiRanger 200, and is designed for a variety of applications: • water and wastewater • storage tanks, for measuring liquids, slurries, and solids • hoppers, ore bunkers, flotation cells MultiRanger 100 The MultiRanger 100 is a single or dual-point level, one, three, or six relay measurement device. It is equipped with digital communications and offers the latest in echo proc

Summary of the content on the page No. 12

If you have any questions, comments, or suggestions about the manual contents, please email us at techpubs.smpi@siemens.com. For the complete library of Siemens Milltronics manuals, go to www.siemens.com/processautomation. Manual Symbols Please note their use carefully. Alternating Current Direct Current Earth (ground) Terminal Protective Conductor Terminal Caution (refer to instructions) Infra-red communication port on front of instrument RJ-11 communications port No co-axial cable connection

Summary of the content on the page No. 13

mmmmm Specifications Specifications Power AC version 1 • 100-230 V AC ± 15%, 50 / 60 Hz, 36 VA (17W) • fuse: F3: 2 AG, Slow Blow, 0.375A, 250V DC version 1 • 12-30 V DC, 20W • fuse: F3: 2 AG, Slow Blow, 2A, 250V Transmitter fuse • F1: Belling Lee, L754, 4000A HRC, ceramic type, 100mA, 250V Temperature Sensor fuse • F2: Belling Lee, L754, 4000A HRC, ceramic type, 50mA, 250V Mounting Location • indoor / outdoor Altitude • 2000 m max. Ambient temperature • -20 to 50 °C (-5 to 122 °F) Relative humid

Summary of the content on the page No. 14

Range • 0.3 m (1 ft) to 15 m (50 ft), dependent on transducer Accuracy • 0.25% of maximum range or 6 mm (0.24”), whichever is greater Resolution 1 • 0.1% of program range or 2 mm (0.08”), whichever is greater Memory • 1 MB static RAM with battery backup • 512 kB flash EPROM Programming Primary • handheld programmer Secondary • PC running SIMATIC PDM • PC running Dolphin Plus software Display • back lit LCD Temperature Compensation • Range: -50 to 150 °C (-58 to 302 °F) Source • integral transduc

Summary of the content on the page No. 15

mmmmm Specifications Fixed • 0.17 % per °C deviation from programmed value Outputs Transducer drive •315 V peak mA Analog MultiRanger 100/200: Single or Dual point versions include two mA outputs • 0-20 mA • 4-20 mA • 750 ohm maximum • Resolution of 0.1% •Isolated 1 Relays •One: •1 control •Three: •2 control • 1 alarm control •Six: •4 control • 2 alarm control • All relays rated 5A at 250 V AC, non-inductive Control Relays • 1, 2 or 4 Form A, NO relays (numbers 1, 2, 4, 5) Alarm Relay • 0, 1 or

Summary of the content on the page No. 16

Inputs mA (analog) (1) [MR 200 only] • 0-20 or 4-20 mA, from alternate device, scalable Discrete (2) • 10-50 V DC switching level • logical 0 = < 0.5 V DC • logical 1 = 10 to 50 V DC • 3 mA maximum draw Enclosure Wall Mount • 240 mm (9.5") x 175 mm (6.9"). Width dimension includes hinges. 1 • Type 4X / NEMA 4X / IP 65 • Polycarbonate Panel Mount • 278 mm (10.93") x 198 mm (7.8") Width dimension includes flange. • Type 3 / Nema 3 / IP54 • Polycarbonate Weight • Wall mount: 1.37 kg (3.02 lb) • Pan

Summary of the content on the page No. 17

mmmmm Specifications Cable • Do not use coaxial cable for transducer (see General Appendix F: Upgrading on page 246 for more information) • transducer and mA output signal to be 2 copper conductors, twisted with shield/drain 2 wire, 300 Vrms, 0.324 - 0.823 mm (22 - 18 AWG), nominal capacitance between adjacent conductors @ 1kHz = 62.3 pF/m (19 pF/ft). Nominal capacitance between 1 conductor and shield @ 1kHz = 108.3 pF/m (33 pF/ft) (Belden® 8760 is acceptable) • 365 m maximum Note: The Mult

Summary of the content on the page No. 18

Installation Notes: • Installation must only be performed by qualified personnel, and in accordance with local governing regulations. • This product is susceptible to electrostatic shock. Follow proper grounding procedures. All field wiring must have insulation suitable for at least 250 V. Hazardous voltage present on transducer terminals during operation. DC terminals shall be supplied from an SELV source in accordance with IEC 1010-1 Annex H. • The non-metallic enclosure does not provid

Summary of the content on the page No. 19

mmmmm Installation Mounting Instructions The wall mount and panel mount units install differently. Please follow the specific instructions for your unit. Note: When routing cable through a conduit, please follow the Cable Routing instructions on page 10 before mounting the MultiRanger. Wall Mount Enclosure Dimensions 14.9 mm 160.3 mm 91 mm (0.58") (6.325") (3.58") 15.2 mm 130 mm 4.3 mm dia. (0.17") (0.6") (5.125") 6.6 mm four mounting (0.26") holes lid screws (6) 240 mm (9.45") 227 m

Summary of the content on the page No. 20

Cable routed through a conduit: 1. Remove the four mounting screws holding the motherboard to the enclosure. 2. Be careful not to damage the electronics with static electricity. Remove the motherboard from the enclosure by pulling the board straight out. 3. Drill the required cable entry holes. Make sure conduit holes do not interfere with the lower areas on the terminal block, circuit board, or SmartLinx card. 4. Attach the conduit to the enclosure using only approved suitable size hubs for


Alternative user manuals
# User manual Category Download
1 Siemens AFI5100 User manual Network Card 44
2 Siemens 6RA70 User manual Network Card 416
3 Siemens ADVANCE NETWORK COMMUNICATIONS BOARD/DATANET 2000592-001 User manual Network Card 10
4 Siemens BC-16 User manual Network Card 4
5 Siemens Brodersen MC55 AT User manual Network Card 1
6 Siemens 81733-2 User manual Network Card 2
7 Siemens DTU3005-B User manual Network Card 7
8 Siemens eWON4002 User manual Network Card 7
9 Siemens Efficient Networks SpeedStream SS1024 User manual Network Card 0
10 Siemens GIGASET 54 User manual Network Card 10
11 Siemens CP 1515 User manual Network Card 3
12 Siemens HC15 User manual Network Card 0
13 Siemens ESM User manual Network Card 4
14 Siemens I-SURF User manual Network Card 21
15 Siemens M34 User manual Network Card 2
16 Sony BTA-NW1A User manual Network Card 2
17 Sony BKMW-E3000 User manual Network Card 2
18 Sony AC-SQ950D User manual Network Card 0
19 Sony BBV RX100 User manual Network Card 3
20 Sony CLIE A-AVZ-100-11 User manual Network Card 1