Summary of the content on the page No. 1
Installation and Operation Manual
IPmux-11
TDM Pseudowire Access
Gateway
Version 2.00
Summary of the content on the page No. 2
Summary of the content on the page No. 3
IPmux-11 TDM Pseudowire Access Gateway Version 2.00 Installation and Operation Manual Notice This manual contains information that is proprietary to RAD Data Communications Ltd. ("RAD"). No part of this publication may be reproduced in any form whatsoever without prior written approval by RAD Data Communications. Right, title and interest, all information, copyrights, patents, know-how, trade secrets and other intellectual property or other proprietary rights relating to this m
Summary of the content on the page No. 4
Limited Warranty RAD warrants to DISTRIBUTOR that the hardware in the IPmux-11 to be delivered hereunder shall be free of defects in material and workmanship under normal use and service for a period of twelve (12) months following the date of shipment to DISTRIBUTOR. If, during the warranty period, any component part of the equipment becomes defective by reason of material or workmanship, and DISTRIBUTOR immediately notifies RAD of such defect, RAD shall have the option to choose the
Summary of the content on the page No. 5
Product Disposal To facilitate the reuse, recycling and other forms of recovery of waste equipment in protecting the environment, the owner of this RAD product is required to refrain from disposing of this product as unsorted municipal waste at the end of its life cycle. Upon termination of the unit’s use, customers should provide for its collection for reuse, recycling or other form of environmentally conscientious disposal. General Safety Instructions The following instructions se
Summary of the content on the page No. 6
In some cases, the users may insert their own SFP laser transceivers into the product. Users are alerted that RAD cannot be held responsible for any damage that may result if non-compliant transceivers are used. In particular, users are warned to use only agency approved products that comply with the local laser safety regulations for Class 1 laser products. Always observe standard safety precautions during installation, operation and maintenance of this product. Only qualified and author
Summary of the content on the page No. 7
The maximum permissible current capability of the branch distribution circuit that supplies power to the product is 16A. The circuit breaker in the building installation should have high breaking capacity and must operate at short-circuit current exceeding 35A. Before connecting the DC supply wires, ensure that power is removed from the DC circuit. Locate the circuit breaker of the panel board that services the equipment and switch it to the OFF position. When connecting the DC supply wir
Summary of the content on the page No. 8
Some SELV and non-SELV circuits use the same connectors. Use caution when connecting cables. Extra caution should be exercised during thunderstorms. When using shielded or coaxial cables, verify that there is a good ground connection at both ends. The earthing and bonding of the ground connections should comply with the local codes. The telecommunication wiring in the building may be damaged or present a fire hazard in case of contact between exposed external wires and the AC power lines
Summary of the content on the page No. 9
FCC-15 User Information This equipment has been tested and found to comply with the limits of the Class A digital device, pursuant to Part 15 of the FCC rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the Installation and Operation manual, may cause harmful interfer
Summary of the content on the page No. 10
Declaration of Conformity Manufacturer's Name: RAD Data Communications Ltd. Manufacturer's Address: 24 Raoul Wallenberg St. Tel Aviv 69719 Israel declares that the product: Product Name: IPmux-11 conforms to the following standard(s) or other normative document(s): EMC: EN 55022: 1998 Information technology equipment – Radio disturbance characteristics – Limits and methods of measurement. EN 50024: 1998 Information technology equipment – Immunity characteristics
Summary of the content on the page No. 11
Quick Start Guide Installation of IPmux-11 should be carried out only by an experienced technician. If you are familiar with IPmux-11, use this guide to prepare the unit for operation. 1. Installing IPmux-11 Connecting the Interfaces 1. Connect the network to the RJ-45 connector designated ETH 1. 2. Connect the user LAN(s) to the RJ-45 connector(s) designated ETH 2 or ETH 3. 3. Connect the E1 or T1 line to the RJ-45 connector designated E1 or T1. Caution When connecting balanced E1
Summary of the content on the page No. 12
Quick Start Guide Installation and Operation Manual Configuring the IP Management Parameters The host IP address, subnet mask and default gateway IP address must be configured via an ASCII terminal. To configure the IP management parameters: • From the Host IP menu (Main > Configuration > System > Host IP), select an IP address of the IPmux-11 host. Configuring E1 and T1 at the Physical Level E1 and T1 interface must be configured at the physical level first. To configure E1 and T1
Summary of the content on the page No. 13
Contents Chapter 1. Introduction 1.1 Overview..................................................................................................................... 1-1 Versions................................................................................................................................1-1 Application...........................................................................................................................1-2 Features.......................................
Summary of the content on the page No. 14
Table of Contents Installation and Operation Manual Chapter 4. Configuration 4.1 Configuration Sequence .............................................................................................. 4-1 4.2 Configuring IPmux-11 for Management ....................................................................... 4-2 Configuring IP Host Parameters.............................................................................................4-2 Configuring Management Parameters...............
Summary of the content on the page No. 15
Chapter 1 Introduction 1.1 Overview IPmux-11 offers a solution for extending traditional E1/T1 transparently over packet switched networks (PSNs) such as IP, Ethernet, and MPLS networks. The device converts the data stream coming from its TDM ports into configurable-sized packets that are extended over the Fast Ethernet network port, and vice versa. IPmux-11 offers end-to-end synchronization for voice/leased line applications. IPmux-11 also features two Fast Ethernet user ports for dat
Summary of the content on the page No. 16
Chapter 1 Introduction Installation and Operation Manual Application Figure 1-1 illustrates a typical IPmux-11 multiplexing voice and Ethernet traffic over an IP link. Figure 1-1. Multiplexing Voice and Ethernet over a Packet-Switched Network Features E1 Interface The E1 port complies with G.703, G.704, and G.823 standards. The E1 port supports unframed, framed and multiframed operation with or without CRC-4. The E1 port supports long haul and short haul input signals and can be mo
Summary of the content on the page No. 17
Installation and Operation Manual Chapter 1 Introduction IP The data stream coming from the E1 or T1 port is converted into IP packets that are transported over the Fast Ethernet ports, and vice versa. TDM bytes are encapsulated in a UDP frame that runs over IP and over Ethernet. The number of TDM bytes in an IP frame is configurable for throughput/delay tradeoff. Each device has a single IP address (host IP). A configurable destination IP address is assigned to the IP packets. IP ToS
Summary of the content on the page No. 18
Chapter 1 Introduction Installation and Operation Manual QoS QoS supports: • Labeling IP level priority (ToS/Diffserv) for TDMoIP packets • VLAN tagging and priority labeling according to IEEE 802.1p&Q for TDMoIP packets • QoS marking of the TDMoIP traffic in MPLS networks. The user can configure the ToS (Type of Service) of the outgoing TDMoIP packets. This allows an en-route Layer 3 router or switch, which supports ToS, to give higher priority to IPmux-11 TDMoIP traffic for delay-se
Summary of the content on the page No. 19
Installation and Operation Manual Chapter 1 Introduction 1.2 Physical Description IPmux-11 is a compact easy-to-install standalone unit. Figure 1-2 shows a 3-dimensional view of IPmux-11. Figure 1-2. IPmux-11 3D View The front panel includes the IPmux-11 LEDs. For the detailed LED description, see Chapter 3. User, network, external clock and management ports, and power supply connector are located on the rear panel of unit. For further details, see Chapter 2. 1.3 Functional Descri
Summary of the content on the page No. 20
Chapter 1 Introduction Installation and Operation Manual Unframed In the unframed mode, the incoming bit stream from each channel (regardless of framing) is converted into IP over Ethernet frames. This option provides clear channel end-to-end service (unframed). Fractional In the fractional mode, the incoming bit stream is regarded as a sequence of N × 64 kbps timeslots (according to framing). Each predefined group of timeslots is converted into a structure block. The structure block