Powerware 5119 user manual

User manual for the device Powerware 5119

Device: Powerware 5119
Category: Network Card
Manufacturer: Powerware
Size: 0.9 MB
Added : 9/15/2013
Number of pages: 42
Print the manual

Download

How to use this site?

Our goal is to provide you with a quick access to the content of the user manual for Powerware 5119. Using the online preview, you can quickly view the contents and go to the page where you will find the solution to your problem with Powerware 5119.

For your convenience

If looking through the Powerware 5119 user manual directly on this website is not convenient for you, there are two possible solutions:

  • Full Screen Viewing - to easily view the user manual (without downloading it to your computer), you can use full-screen viewing mode. To start viewing the user manual Powerware 5119 on full screen, use the button Fullscreen.
  • Downloading to your computer - You can also download the user manual Powerware 5119 to your computer and keep it in your files. However, if you do not want to take up too much of your disk space, you can always download it in the future from ManualsBase.
Powerware 5119 User manual - Online PDF
Advertisement
« Page 1 of 42 »
Advertisement
Print version

Many people prefer to read the documents not on the screen, but in the printed version. The option to print the manual has also been provided, and you can use it by clicking the link above - Print the manual. You do not have to print the entire manual Powerware 5119 but the selected pages only. paper.

Summaries

Below you will find previews of the content of the user manuals presented on the following pages to Powerware 5119. If you want to quickly view the content of pages found on the following pages of the manual, you can use them.

Abstracts of contents
Summary of the content on the page No. 1

02/15/01
®
Powerware 5119
User’s Guide
1000-3000 VA
www.powerware.com

Summary of the content on the page No. 2

Requesting a Declaration of Conformity The EC Declaration of Conformity is available upon request for products with a CE mark. For copies of the EC Declaration of Conformity, contact: Powerware Corporation Koskelontie 13 FIN-02920 Espoo Finland Phone: +358-9-452661 Fax: +358-9-452-66395 EMC Statement Some configurations are classified under EN50091-2 as “Class-A UPS for Unrestricted Sales Distribution.” For these configurations, the following applies: WARNING This is a Class A-UPS Product. In a

Summary of the content on the page No. 3

Summary of the content on the page No. 4

Special Symbols The following are examples of symbols used on the UPS to alert you to important information: CAUTION Risk of Electric Shock Do Not Open Cover CAUTION To reduce the risk of electric shock, Do not remove cover (or back) No user-serviceable parts inside Refer servicing to the factory RISK OF ELECTRIC SHOCK - Indicates that a risk of electric shock is present and the associated warning should be observed. CAUTION: REFER TO OPERATOR’S MANUAL - Refer to your operator’s manual for addit

Summary of the content on the page No. 5

TABLE OF CONTENTS 1 Powerware 5119 – One of the Best! .................................. 1 2 Installation ..................................................... 3 Inspecting the Equipment ....................................................... 3 Safety Precautions ............................................................ 3 Installing the UPS ............................................................. 4 UPS Rear Panels .............................................................. 7 3 Operati

Summary of the content on the page No. 6

Table of Contents 6 Additional UPS Features .......................................... 25 Communication Port Configurations ................................................ 25 Communication Indicator ..................................................... 25 Pin Out .................................................................. 26 Network Transient Protector ..................................................... 27 Load Segments .............................................................. 27

Summary of the content on the page No. 7

CHAPTER 1 POWERWARE 5119 – ONE OF THE BEST! 9 The Powerware 5119 uninterruptible power system (UPS) protects your sensitive electronic equipment from basic power problems such as power failures, power sags, power surges, brownouts, and line noise. Power outages can occur when you least expect it and power quality can be erratic. These power problems have the potential to corrupt critical data, destroy unsaved work sessions, and damage hardware — causing hours of lost productivity and expensive r

Summary of the content on the page No. 8

Powerware 5119 – One of the Best! Providing outstanding performance and reliability, the Powerware 5119’s unique benefits include the following: : Advanced Battery Management (ABM Z ) doubles battery service life, optimizes recharge time, and provides a warning up to 60 days before the end of useful battery life. : Buck and Double Boost regulation ensures consistent voltage to your load by correcting voltage fluctuations without using battery power. : Hot-swappable batteries simplify maintenance

Summary of the content on the page No. 9

CHAPTER 2 INSTALLATION This section explains: : Equipment inspection : Safety precautions : UPS installation : UPS rear panels Inspecting the Equipment If any equipment has been damaged during shipment, keep the shipping cartons and packing materials for the carrier or place of purchase and file a claim for shipping damage. If you discover damage after acceptance, file a claim for concealed damage. To file a claim for shipping damage or concealed damage: 1) File with the carrier within 15 days o

Summary of the content on the page No. 10

Installation WARNING : This UPS contains its own energy source (batteries). The output receptacles may carry live voltage even when the UPS is not connected to an AC supply. : Do not remove or unplug the input cord when the UPS is turned on. This removes the safety ground from the UPS and the equipment connected to the UPS. : To reduce the risk of fire or electric shock, install this UPS in a temperature and humidity controlled, indoor environment, free of conductive contaminants. Ambient temper

Summary of the content on the page No. 11

Installation 3. On 230V models, plug the UPS power cord into the input connector on the UPS rear panel. Customer-supplied power cords must correctly rated for the UPS (see “Specifications” on page 29). You can also use the power cord from the largest load if it is correctly rated. 4. Plug the UPS power cord into a wall outlet or power source. The UPS conducts a self-test and enters Standby mode. If a red Site Wiring Fault or Battery Service indicator stays on, see Table 11 on page 33. Site Wirin

Summary of the content on the page No. 12

Summary of the content on the page No. 13

Summary of the content on the page No. 14

Summary of the content on the page No. 15

Installation Communication Port 10A, IEC-320 Input Connector Battery Connector Input Circuit Breaker Load Segment 1 (Three IEC-320 Receptacles) / 2 $ Load Segment 2 Option Slot ’ (Three IEC-320 Receptacles) Load Segment 3 Network (Three IEC-320 Receptacles) Transient Protector Figure 8. 2000-2400 VA, 230V Rear Panel Communication Port 16A, IEC-320 Input Connector Battery Connector Output Circuit Breakers Input Circuit Breaker Load Segment 1 (Three IEC-320 Receptacles) Option Slot Load Segment

Summary of the content on the page No. 16

Installation ® Powerware 5119 User’s Guide : www.powerware.com 10

Summary of the content on the page No. 17

Summary of the content on the page No. 18

Summary of the content on the page No. 19

Summary of the content on the page No. 20

Operation Load Level LEDs The front panel displays the total load current or watts plugged into the UPS (see Figure 13). 66-100% 33-66% 5-33% Figure 13. Load Level LEDs (Normal Mode) Each LED represents 1/3 of a full load rating. When the UPS is approximately fully loaded (66-100%), all three LEDs illuminate. If the load is 33-66% of UPS capacity, the third and fourth LED illuminate. The last LED illuminates if the load is between 5% and 33%. If any Load Level LEDs are red, see page 35 for more


Alternative user manuals
# User manual Category Download
1 Powerware 3110 User manual Network Card 18
2 Powerware 5115 User manual Network Card 69
3 Powerware 5125 User manual Network Card 57
4 Powerware 700 3000 VA User manual Network Card 0
5 Powerware 700 VA User manual Network Card 0
6 Powerware FCC 15 User manual Network Card 0
7 Powerware 5115 RM User manual Network Card 2
8 Powerware IPK-0320 User manual Network Card 0
9 Powerware BestLink IPK-0319 User manual Network Card 0
10 Powerware IPK-0318 User manual Network Card 0
11 Powerware E.T.N 1500 VA - 60kVa User manual Network Card 3
12 Powerware 9315 User manual Network Card 14
13 Powerware Uninterruptible Power Supply SOLA 4000 User manual Network Card 0
14 Powerware UPS Sidecar9390 User manual Network Card 160
15 Powerware 300 VA User manual Network Card 0
16 Sony BTA-NW1A User manual Network Card 2
17 Sony BKMW-E3000 User manual Network Card 2
18 Sony AC-SQ950D User manual Network Card 0
19 Sony BBV RX100 User manual Network Card 3
20 Sony CLIE A-AVZ-100-11 User manual Network Card 1