Paradyne 8610 user manual

User manual for the device Paradyne 8610

Device: Paradyne 8610
Category: Network Card
Manufacturer: Paradyne
Size: 0.42 MB
Added : 3/31/2014
Number of pages: 38
Print the manual

Download

How to use this site?

Our goal is to provide you with a quick access to the content of the user manual for Paradyne 8610. Using the online preview, you can quickly view the contents and go to the page where you will find the solution to your problem with Paradyne 8610.

For your convenience

If looking through the Paradyne 8610 user manual directly on this website is not convenient for you, there are two possible solutions:

  • Full Screen Viewing - to easily view the user manual (without downloading it to your computer), you can use full-screen viewing mode. To start viewing the user manual Paradyne 8610 on full screen, use the button Fullscreen.
  • Downloading to your computer - You can also download the user manual Paradyne 8610 to your computer and keep it in your files. However, if you do not want to take up too much of your disk space, you can always download it in the future from ManualsBase.
Paradyne 8610 User manual - Online PDF
Advertisement
« Page 1 of 38 »
Advertisement
Print version

Many people prefer to read the documents not on the screen, but in the printed version. The option to print the manual has also been provided, and you can use it by clicking the link above - Print the manual. You do not have to print the entire manual Paradyne 8610 but the selected pages only. paper.

Summaries

Below you will find previews of the content of the user manuals presented on the following pages to Paradyne 8610. If you want to quickly view the content of pages found on the following pages of the manual, you can use them.

Abstracts of contents
Summary of the content on the page No. 1

HOTWIRE 8610 DSLAM
INSTALLATION INSTRUCTIONS
Document No. 8610-A2-GN10-10

Summary of the content on the page No. 2

Copyright  1999 Paradyne Corporation. All rights reserved. Printed in U.S.A. Notice This publication is protected by federal copyright law. No part of this publication may be copied or distributed, transmitted, transcribed, stored in a retrieval system, or translated into any human or computer language in any form or by any means, electronic, mechanical, magnetic, manual or otherwise, or disclosed to third parties without the express written permission of Paradyne Corporation, 8545 126th Ave. N

Summary of the content on the page No. 3

TM Hotwire 8610 DSLAM Installation Instructions Document Number 8610-A2-GN10-10 May 1999 Product Documentation on the World Wide Web We provide complete product documentation online. This lets you search the documentation for specific topics and print only what you need, reducing the waste of surplus printing. It also helps us maintain competitive prices for our products. Complete documentation for this product is available at www.paradyne.com. Select Library → Technical Manuals → Hotwire DSL

Summary of the content on the page No. 4

About This Document This guide is written for administrators and technicians who install devices at the central office (CO) or at a Network Service Provider (NSP) location adjacent to the CO. It should be used in conjunction with the appropriate Hotwire DSL card User’s Guide or Network Configuration Guide, which describes how to plan the data networks surrounding the DSLAM and specific DSL cards. To install the customer premises (CP) portion of the Hotwire 8610 DSLAM, refer to the appropriate Ho

Summary of the content on the page No. 5

The 8610 DSLAM accepts the following types of cards:  Management Control Processor (MCP). This is a processor card that administers and provides diagnostic connectivity to the DSL cards. It acts as a mid-level manager and works in conjunction with an SNMP network management system, such as HP OpenView, via its LAN port. It gathers operational status for each of the DSL cards and responds to the SNMP requests. It also has a serial port for local terminal access.  MVL, RADSL and DSL cards. These

Summary of the content on the page No. 6

 Stackable Chassis for DSL Access Growth Each chassis is an independent, standalone system. The 8610 and 8600 chassis are interoperable in a stack. The stackable design provides for six systems to share management access through a single MCP card (for 8610) or MCC card (for 8600) which, in turn, allows an additional slot for a DSL card in each of up to five additional systems. In a stacked configuration, the first or base chassis is equipped with an MCP/MCC card in Slot 1 leaving Slots 2 and 3

Summary of the content on the page No. 7

Hotwire 8610 DSLAM Components TM TM 3 8610 2 ESD ESD MCP/ 1 DSL MANAGEMENT 10 BASE T DC FUSES 48VDC CLASS 2 T4A, MIN. 48V OR LIMITED FAN PWR PWR SOURCE 5 6 4 3 2 AC 1 ALM A B A B STACK A B AB IN OUT SERIAL ALM INTF MCP/1 2 3 INPUT POSITION 48V RTN 99-16311 The Hotwire 8610 DSLAM consists of the following components:  Hotwire 8610 DSLAM base chassis Hotwire 8610 DSLAM is a 3-slot chassis designed to house one MCP card in the first slot and up to two DSL cards in the remaining slots. Since the MC

Summary of the content on the page No. 8

Preinstallation Considerations Consider the following before performing installation of the 8610 chassis:  Installation Site Your installation site should be well ventilated, clean, and free of environmental extremes. If you are installing the Hotwire 8610 DSLAM chassis in a central office rack, make sure there is 2 to 3 feet of clearance at the front of the rack in which the 8610 chassis is to be installed to allow access for the installation of the chassis, circuit cards, and cables. Also all

Summary of the content on the page No. 9

— 14-foot serial cable and DB25 and DB9 adapters are shipped with the MCP card. For connection to a modem, you will need a NULL modem adapter. If there is adequate maintenance space at the rear of the rack, mount the chassis on the rack before installing cables. If there is inadequate space to do this, install the rear-mounted network connectors on the chassis before mounting the chassis on the rack. CAUTION: Use of any nontwisted pair wiring arrangements, such as jumpers, can cause reduction in

Summary of the content on the page No. 10

Be sure to register your warranty at www.paradyne.com. Select Service & Support → Warranty Registration. Mounting Configurations The Hotwire 8610 DSLAM chassis can be mounted in any commercial Electronic Industries Association (EIA) standard 19- or 23-inch rack. TM Both 19- and 23-inch TM 3 8610 2 ESD ESD rack-mounting hardware is MCP/ 1 DSL DC FUSES MANAGEMENT 10 BASE T provided with the unit. In a 48VDC CLASS 2 T4A, MIN. 48V PWR OR LIMITED FAN PWR SOURCE 4 5 6 3 2 AC 1 A B AB A B ALM A B STACK

Summary of the content on the page No. 11

Hotwire 8610 DSLAM Chassis Installation The Hotwire 8610 DSLAM chassis is designed to be stacked one on top of the other on a desktop or table, or mounted in a 19-or 23-inch rack (front or center mount). Up to three 8610 chassis can be stacked on a table or desktop. Mounting brackets are provided for mounting in 19- or 23-inch racks. You will need a large, flat-blade screwdriver and a Phillips screwdriver to install the 8610 chassis in a commercial EIA-standard 19- or 23-inch rack. You will need

Summary of the content on the page No. 12

Interconnecting 8610 Systems  Procedure To interconnect multiple 8610 systems: 1. Connect the end of an 8-pin modular cable into the Management OUT port of the base chassis. 2. Dress the 8-pin modular cable to the left and under the chassis, behind the foot, and up the side of the unit. 3. Plug the other end of the 8-pin modular cable into the Management IN port of the 8610 chassis above, dressing the cable as in the previous step. 4. Repeat for the next 8610 chassis, connecting the Management

Summary of the content on the page No. 13

The following illustration shows the designated number for each DSL card slot in a stack. NOTE: This illustration shows a stack of six Hotwire 8610 systems, which is valid for rack mounting. However, the same relationship of software-assigned slot numbers applies to two stacks of three each, mounted on a desk or tabletop and connected by a bus cable. The base chassis must still have the MCP card in physical Slot 1 with the base chassis Stack Position switch set to 1. The software does not assign

Summary of the content on the page No. 14

Installing the 8610 Chassis in a Rack with Threaded Screw Holes NOTE: You may want to install the three supplied #4-40 Phillips pan-head screws for the rear Telco connectors on the rear connectors before rack mounting the DSLAM. This will make them readily available when needed. See Installing Network Tip and Ring Connections on page 21 for more information.  Procedure To install the 8610 chassis in a rack that has threaded screw holes: 1. Install the mounting brackets on the 8610 chassis by r

Summary of the content on the page No. 15

Installing the 8610 Chassis in a Rack without Threaded Screw Holes  Procedure To install the 8610 chassis in a rack that does not have threaded screw holes: 1. Install the mounting brackets on the 8610 chassis. — For a 19-inch rack installation, the notched flange of the mounting bracket is placed against the side of the 8610 chassis. — For a 23-inch rack installation, the smaller flange of the mounting bracket is placed against the side of the 8610 chassis. 2. Determine the preferred placemen

Summary of the content on the page No. 16

Center-Mounting the 8610 Chassis in a Rack  Procedure To center-mount the 8610 chassis in a rack: 1. Determine the preferred placement of the 8610 chassis in the rack. Then, mark the appropriate locations for the mounting screws on the rack. 2. Reposition the mounting brackets to the center-mount position using the four #8-32 screws supplied with the chassis. 3. Fasten the chassis to the rack. Insert the screws through the rack and into the two screw holes located in the center of each side of

Summary of the content on the page No. 17

Supplying Power The Hotwire 8610 DSLAM chassis is available in two versions:  dc power (–40.0 to –60.0 Vdc; maximum current draw is 2 amps) — The dc version has two separate dc inputs, A and B, to provide power redundancy.  ac power (100–250V; 50–60 Hz; maximum current draw is 3 amps @ 110 Vac) — The ac version can provide power redundancy if a separate –48 Vdc source is connected to the B input terminal. CAUTION: It is recommended that the following procedures be performed by a qualified elec

Summary of the content on the page No. 18

2. Dress the wires under the 8610 chassis to the left behind the support foot. 3. Power the Hotwire 8610 DSLAM AB A B chassis. –48V RTN 4. Make sure the PWR A LED on the front panel is ON (green). 99-16316 Using Two DC Power Sources for Power Redundancy  Procedure To supply two dc power sources to the 8610 chassis for power redundancy: Make sure that the dc power source wires are not powered (i.e., the circuit breakers are open). The ends of the power source wires (14–18 AWG solid or stranded w

Summary of the content on the page No. 19

2. Dress the wires under the 8610 chassis to the left behind the support foot. 3. Power the Hotwire 8610 DSLAM AB A B chassis. –48V RTN 4. Make sure the PWR A and PWR B LEDs on the front panel are both ON (green). 99-16317 Using Only AC Power Source  Procedure To supply power to the 8610 chassis using a single ac power source: 1. Plug the ac power cord into the IEC 320 receptacle labeled AC INPUT. 2. Plug the other end of the ac power cord into your ac power outlet. NOTE: The ac power source sh

Summary of the content on the page No. 20

2. Insert the wires for the dc power source into the appropriate terminal and securely fasten each wire by tightening the screw above it. The insulation should be fully within the terminal block and no bare wire should be exposed outside of the block. NOTE: You should clearly label these power source wires as –48V and RTN respectively. Insert Power Source B’s . . . Into the . . . Negative side –48V B input terminal. Positive side RTN B (return) terminal. 3. Dress the wires under the 8610 chassis


Alternative user manuals
# User manual Category Download
1 Paradyne 12-Port T1 Access Multiplexer TAM1500-12 User manual Network Card 0
2 Paradyne 12-Port VoSHDSL Access Multiplexer SAM2000GV-12 User manual Network Card 0
3 Paradyne 12-Port SHDSL Access Multiplexer SAM2000G-12 User manual Network Card 0
4 Paradyne 1810 User manual Network Card 0
5 Paradyne 24-Port SHDSL Mini DSLAM SMD2000-24T User manual Network Card 0
6 Paradyne 3160 User manual Network Card 1
7 Paradyne 12-Port VoSHDSL Access Multiplexer SAM2000V-12 User manual Network Card 0
8 Paradyne 3160-A3 User manual Network Card 0
9 Paradyne 3162 User manual Network Card 0
10 Paradyne 3160-A4 User manual Network Card 0
11 Paradyne 12-Port VoSHDSL Access Multiplexer SAM2000QV-12 User manual Network Card 0
12 Paradyne 3161 User manual Network Card 0
13 Paradyne 3161-B3 User manual Network Card 0
14 Paradyne 3162 DSU/CSU User manual Network Card 0
15 Paradyne 3164 User manual Network Card 0
16 Sony BTA-NW1A User manual Network Card 2
17 Sony BKMW-E3000 User manual Network Card 2
18 Sony AC-SQ950D User manual Network Card 0
19 Sony BBV RX100 User manual Network Card 3
20 Sony CLIE A-AVZ-100-11 User manual Network Card 1