Paradyne 8416-A1-000 user manual

User manual for the device Paradyne 8416-A1-000

Device: Paradyne 8416-A1-000
Category: Network Card
Manufacturer: Paradyne
Size: 0.61 MB
Added : 3/31/2014
Number of pages: 18
Print the manual

Download

How to use this site?

Our goal is to provide you with a quick access to the content of the user manual for Paradyne 8416-A1-000. Using the online preview, you can quickly view the contents and go to the page where you will find the solution to your problem with Paradyne 8416-A1-000.

For your convenience

If looking through the Paradyne 8416-A1-000 user manual directly on this website is not convenient for you, there are two possible solutions:

  • Full Screen Viewing - to easily view the user manual (without downloading it to your computer), you can use full-screen viewing mode. To start viewing the user manual Paradyne 8416-A1-000 on full screen, use the button Fullscreen.
  • Downloading to your computer - You can also download the user manual Paradyne 8416-A1-000 to your computer and keep it in your files. However, if you do not want to take up too much of your disk space, you can always download it in the future from ManualsBase.
Paradyne 8416-A1-000 User manual - Online PDF
Advertisement
« Page 1 of 18 »
Advertisement
Print version

Many people prefer to read the documents not on the screen, but in the printed version. The option to print the manual has also been provided, and you can use it by clicking the link above - Print the manual. You do not have to print the entire manual Paradyne 8416-A1-000 but the selected pages only. paper.

Summaries

Below you will find previews of the content of the user manuals presented on the following pages to Paradyne 8416-A1-000. If you want to quickly view the content of pages found on the following pages of the manual, you can use them.

Abstracts of contents
Summary of the content on the page No. 1

®
Hotwire Shelf Concentration and Processing (SCP) Card
Installation Instructions
Document Number 8400-A2-GZ40-10
October 2003
Hotwire Shelf Concentration and Processing Card
®
A Hotwire Shelf Concentration and Processing (SCP) card is a circuit card
assembly that comprises a parent card with an ATM switch, a backplane interface,
a processor, a cell multiplexer/demultiplexer, and an uplink childcard. The
childcard determines the type of ATM uplink supported by the SCP card.
When the SCP card

Summary of the content on the page No. 2

Product Documentation Online Complete documentation for this product is available at www.paradyne.com. Select Support → Technical Manuals → Hotwire DSL Systems. Select the following documents: 8400-A2-GB20 Hotwire Shelf Concentration and Processing (SCP) Card User’s Guide 8620-A2-GN20 Hotwire 8620 GranDSLAM Installation Guide 8820-A2-GN20 Hotwire 8820 GranDSLAM Installation Guide 8900-A2-GB20 Hotwire ATM Line Cards, Models 8955, 8965, and 8985, User’s Guide To order a paper copy of a Paradyne d

Summary of the content on the page No. 3

SYSTEM OK Alm Test ETHERNET TX RX Coll DSL PORT 1 2 3 4 SYSTEM OK Alm Test ETHERNET TX RX Coll T Te T o SYS EM OK Alm st ETHERNET X RX C ll POWER ALARMS A B Fan Major Minor CLOCK SERIAL AC LAN/WAN SLOT A MCC ALARM 2 4 6 8 A 10 12 14 16 18 B SERIAL ALARM 1 3 5 7 9 B 11 13 15 17 CLOCK SMCM POWER ENTRY MODULE POWER ENTRY MODULE LEFT UNIT: LINE A LEFT UNIT: LINE A RIGHT UNIT: LINE B RIGHT UNIT: LINE B WARNING! POWER MUST BE DISCONNECTED AT THE SOURCE WARNING! POWER MUST BE DISCONNECTED AT THE SOURC

Summary of the content on the page No. 4

Installing Two SCP Cards in the Same DSLAM Two SCP cards may be installed in one DSLAM to provide redundancy or load sharing. There are three basic configurations for paired SCP cards:  Y-Cable – The OC3 ports of the two SCP cards are connected to the same uplink device. If the active SCP card fails, the backup SCP card automatically becomes the uplink. See Equipment List on page 15 for available Y-cables.  Dual Link – Automatic switching occurs in the event of failure, but the SCP cards

Summary of the content on the page No. 5

SYSTEM Active Standby Alarm Test ETHERNET TX RX UPLINK LK 1 DS3 Uplink SCP cards with a DS3 uplink have two BNC jacks: one for the transmit direction and one for the receive direction. To cable an SCP card with an DS3 uplink: 1. Connect the input cable to the RX jack on the faceplate of the SCP card. 2. Connect the output cable to the TX jack on the faceplate of the SCP card. 3. If the chassis is mounted in a rack, direct the cables toward the nearest rail and fasten them with cable ties. 03-

Summary of the content on the page No. 6

SYSTEM Active Standby Alarm Test ETHERNET TX RX UPLINK LK 1 OC3 Uplink SCP cards with an OC3 uplink use an SFP transceiver that accepts an LC-type connector. To cable an SCP card with an OC3 uplink: 1. Remove the plastic dustcover from the SFP socket. 2. Insert the LC connector of your fiber optic cable into the SFP socket. 3. Observing the minimum bend radius for your cable, fasten it with cable ties in such a way that it will not be kinked or snagged in the course of other cabling. If you d

Summary of the content on the page No. 7

SYSTEM Active Standby Alarm Test ETHERNET TX RX UPLINK LK5 LK1 LK6 LK2 LK7 LK3 LK8 LK4 IMA Uplink SCP cards with an IMA uplink have an RJ45M-type 50-position connector with eight Tip/Ring and eight Tip1/Ring1 connections that conforms to ANSI T1.403-1999. The following splitter cables are available:  Feature Number 8026-F1-001 for the Model 8416 SCP card terminates in eight 8-pin modular jacks. See Table 2, Feature Number 8026-F1-001 Pin Assignments, on page 12. To connect the SCP card to a

Summary of the content on the page No. 8

SYSTEM Active Standby Alarm Test SYSTEM Active ETHERNET Standby TX Alarm RX Test ETHERNET TX UPLINK RX LK 1 UPLINK LK 1 SYSTEM Active Standby Alarm Test ETHERNET TX RX UPLINK LK5 LK1 LK6 LK2 LK7 LK3 LK8 LK4 SCP Card LEDs The following table describes the meaning and states of the LEDs on the Hotwire SCP card faceplate. Example faceplates are shown at left. Type LED LED is . . . Indicating . . . SYSTEM Active Green, This SCP card is the active card Slow-cycling and is functioning normally. Slo

Summary of the content on the page No. 9

Using the Default Management Address The SCP card uses Transaction Language 1 (TL1) language for Command Line Interface (CLI) commands and messages. The CLI can be used to configure and maintain the system, but the web interface is recommended. You can access the web interface using the default management address or a network address you specify using the CLI (see Setting the Management Address Using the CLI). Procedure To use the default management address: 1. Connect a PC to the Ethernet p

Summary of the content on the page No. 10

Setting the Management Address Using the CLI The management address can be set using the CLI. Procedure To set the management address of the SCP card using the CLI: 1. Using the supplied cable and DB9 adapter, connect a PC with a terminal emulation program to the SERIAL SCM jack of your GranDSLAM. This gives you access to the CLI. 2. Log in to the SCP card using the ACT-USER command: ACT-USER::SUPERUSER:::ASN#1500 The default password, ASN#1500, will appear as asterisks on your screen. 3. Assi

Summary of the content on the page No. 11

Using the Web Interface To access the web interface: Procedure 1. Open your web browser. (Internet Explorer Version 6 or above is recommended.) 2. Type http:// and the IP address of the SCP card into the Address field of your browser window. This is 10.10.10.10 by default, or the address you set using the CLI. For example: 3. A login window appears. Enter the default User ID (SUPERUSER) and Password (ASN#1500), and click on OK. The web interface screen appears. 4. Click on the menu tab appro

Summary of the content on the page No. 12

BNC Jacks The following table shows the connections for BNC jacks (Model 8411). Table 1. BNC Jack Connections Connector Label Connection Description Transmit TX Pin Transmit signal Shell Transmit signal return Receive RX Pin Receive signal Shell Receive signal return IMA Interface Pin Assignments Table 2 lists connector pin assignments for Model 8416, and the Model 8417 when used with modular connectors for a 120-ohm E1 connection. Table 3 lists connector pin assignments for the Model 8417 whe

Summary of the content on the page No. 13

Table 2. Feature Number 8026-F1-001 Pin Assignments (2 of 2) 8026-F1-001 DS1 or 120 Ohm 50-Position Telco RJ48C Connector E1 Port Connector Pinouts Pinouts Function Port 5 39 5 Data Out (Tip) 14 4 Data Out (Ring) 38 2 Data In (Tip) 13 1 Data In (Ring) Port 6 42 5 Data Out (Tip) 17 4 Data Out (Ring) 41 2 Data In (Tip) 16 1 Data In (Ring) Port 7 45 5 Data Out (Tip) 20 4 Data Out (Ring) 44 2 Data In (Tip) 19 1 Data In (Ring) Port 8 48 5 Data Out (Tip) 23 4 Data Out (Ring) 47 2 Data In (Tip) 22 1 D

Summary of the content on the page No. 14

Table 3. Feature Number 8027-F1-001 Pin Assignments (2 of 2) 50-Position Telco 75 Ohm E1 Port Function Connector Pinouts BNC Connector Port 3 Data In 7 Shell (Ring) 32 Pin (Tip) Data Out 8 Shell (Ring) 33 Pin (Tip) Port 4 Data In 10 Shell (Ring) 35 Pin (Tip) Data Out 11 Shell (Ring) 36 Pin (Tip) Port 5 Data In 13 Shell (Ring) 38 Pin (Tip) Data Out 14 Shell (Ring) 39 Pin (Tip) Port 6 Data In 16 Shell (Ring) 41 Pin (Tip) Data Out 17 Shell (Ring) 42 Pin (Tip) Port 7 Data In 19 Shell (Ring) 44 Pin

Summary of the content on the page No. 15

Equipment List The following feature numbers may be used to order SCP cards, line cards, and related cables. Table 4. Feature Numbers Description Feature Number Cards SCP Card: DS3 8411-A1-000 SCP Card: OC3/STM1 Multimode Fiber 8412-A1-000 SCP Card: OC3/STM1 Single Mode Fiber Intermediate Reach 8413-A1-000 SCP Card: OC3/STM1 Single Mode Fiber Long Reach 8414-A1-000 SCP Card: 8-Port DS1 IMA 8416-A1-000 SCP Card: 8-Port E1 IMA 8417-A1-000 MCP GranDSLAM 3.0 8900-B1-211 ADSL2 ATM Line Card 24 port

Summary of the content on the page No. 16

SCP Card Technical Specifications Table 5. SCP Card Technical Specifications (1 of 2) Specifications Criteria Size Length: 10.4 inches (26.42 cm) Height: 11.15 inches (28.32 cm) Width: 1.0 inches (2.54 cm) Weight Approximately 1.7 lbs. (0.76 kg) Approvals Safety Certifications Refer to the equipment’s label for approvals on product. Power The SCP card contains a DC-to-DC converter that requires 48V power input. The 48V power is distributed through the Hotwire chassis backplane. Power Dissipati

Summary of the content on the page No. 17

Table 5. SCP Card Technical Specifications (2 of 2) Specifications Criteria OC3 Uplink Specifications Number of ports 1 OC3 Connector Type Duplex LC Socket Standards Supported ANSI T1.105.06-94 Jitter, ANSI T1.105.09 94 Jitter, ANSI T1.117.06-91, ITU-T G.957 7/95 Frame Formats OC3 or STM-1 Operation, Direct Mode only Line Type Non-Return to Zero Data Rates Supported 155.52 Mbps Facility Datalink Protocol ANSI T1.105 Format, ANSI T1.646 HEC, ITU-T I.432 Scrambler Cable Distance Model 8412 (MMF)

Summary of the content on the page No. 18

Warranty, Sales, Service, and Training Information Contact your local sales representative, service representative, or distributor directly for any help needed. For additional information concerning warranty, sales, service, repair, installation, documentation, training, distributor locations, or Paradyne worldwide office locations, use one of the following methods:  Internet: Visit the Paradyne World Wide Web site at www.paradyne.com. (Be sure to register your warranty at www.paradyne.com


Alternative user manuals
# User manual Category Download
1 Paradyne 12-Port T1 Access Multiplexer TAM1500-12 User manual Network Card 0
2 Paradyne 12-Port VoSHDSL Access Multiplexer SAM2000GV-12 User manual Network Card 0
3 Paradyne 12-Port SHDSL Access Multiplexer SAM2000G-12 User manual Network Card 0
4 Paradyne 1810 User manual Network Card 0
5 Paradyne 24-Port SHDSL Mini DSLAM SMD2000-24T User manual Network Card 0
6 Paradyne 3160 User manual Network Card 1
7 Paradyne 12-Port VoSHDSL Access Multiplexer SAM2000V-12 User manual Network Card 0
8 Paradyne 3160-A3 User manual Network Card 0
9 Paradyne 3162 User manual Network Card 0
10 Paradyne 3160-A4 User manual Network Card 0
11 Paradyne 12-Port VoSHDSL Access Multiplexer SAM2000QV-12 User manual Network Card 0
12 Paradyne 3161 User manual Network Card 0
13 Paradyne 3161-B3 User manual Network Card 0
14 Paradyne 3162 DSU/CSU User manual Network Card 0
15 Paradyne 3164 User manual Network Card 0
16 Sony BTA-NW1A User manual Network Card 2
17 Sony BKMW-E3000 User manual Network Card 2
18 Sony AC-SQ950D User manual Network Card 0
19 Sony BBV RX100 User manual Network Card 3
20 Sony CLIE A-AVZ-100-11 User manual Network Card 1