Panasonic AQ-C Relays user manual

User manual for the device Panasonic AQ-C Relays

Device: Panasonic AQ-C Relays
Category: Network Card
Manufacturer: Panasonic
Size: 0.1 MB
Added : 8/6/2014
Number of pages: 5
Print the manual

Download

How to use this site?

Our goal is to provide you with a quick access to the content of the user manual for Panasonic AQ-C Relays. Using the online preview, you can quickly view the contents and go to the page where you will find the solution to your problem with Panasonic AQ-C Relays.

For your convenience

If looking through the Panasonic AQ-C Relays user manual directly on this website is not convenient for you, there are two possible solutions:

  • Full Screen Viewing - to easily view the user manual (without downloading it to your computer), you can use full-screen viewing mode. To start viewing the user manual Panasonic AQ-C Relays on full screen, use the button Fullscreen.
  • Downloading to your computer - You can also download the user manual Panasonic AQ-C Relays to your computer and keep it in your files. However, if you do not want to take up too much of your disk space, you can always download it in the future from ManualsBase.
Panasonic AQ-C Relays User manual - Online PDF
Advertisement
« Page 1 of 5 »
Advertisement
Print version

Many people prefer to read the documents not on the screen, but in the printed version. The option to print the manual has also been provided, and you can use it by clicking the link above - Print the manual. You do not have to print the entire manual Panasonic AQ-C Relays but the selected pages only. paper.

Summaries

Below you will find previews of the content of the user manuals presented on the following pages to Panasonic AQ-C Relays. If you want to quickly view the content of pages found on the following pages of the manual, you can use them.

Abstracts of contents
Summary of the content on the page No. 1

AQ-C
Please contact us about TÜV certified products.
Miniature DIL 1A control
AQ-C RELAYS
type for PCBs
FEATURES TYPICAL APPLICATIONS
• Compact DIL type: • Compact AC motor, Solenoid,
L20 mm × W10 mm × H12.8 mm Magnet, Driver of magnetic valve
(.787×.394×.504 inch) • Copying equipment
• Excellent in noise resistance • NC machine, Robot
•Snubber circuit integrated •Programmable controller
• High dielectric strength: 2,500 V • Air conditioners
between input and output
•Reverse polarity type avai

Summary of the content on the page No. 2

AQ-C 2. Output module Type Load voltage Input voltage Part No. 5 V DC AQC1A1 - ZT5 V DC 75 to 125 V AC 12 V DC AQC1A1 - ZT12 V DC 24 V DC AQC1A1 - ZT24 V DC AC output Zero-cross 5 V DC AQC1A2 - ZT5 V DC 75 to 250 V AC 12 V DC AQC1A2 - ZT12 V DC 24 V DC AQC1A2 - ZT24 V DC 5 V DC AQC1A1 - T 5 V DC 75 to 125 V AC 12 V DC

Summary of the content on the page No. 3

AQ-C Characteristics [at 20°C 68°F; Input voltage ripple (output module) and output voltage ripple (input module): max. 1%] Input module Type AC Input DC Input Remarks Item Operate time, max. 20 ms 0.5 ms Input voltage: 24 V DC or 100V AC Output voltage: 24 V DC Release time, max 20 ms 0.5 ms Output current: 25mA 9 Insulation resistance, min. 10 Ω between input and output at 500 V DC Breakdown voltage 2,500 Vrms between input and output For 1 minute Destructive 10 to 55Hz double amplitude of 3 m

Summary of the content on the page No. 4

AQ-C 5. Load current vs. ambient temperature characteristics for adjacent mounting 1.0 =20.32 mm .800 inch =12.7 mm 0.8 .500 inch 0.6 0.4 0.2 =Adjacent mounting pitch 0 –30 0 20 40 60 80 Ambient temperature, °C The CAD data of the products with a CAD Data mark can be downloaded from: http://panasonic-electric-works.net/ac DIMENSIONS (mm inch) PC board pattern (Copper-side view) 1. Input module (AC, DC) 10 10.16 7.62 CAD Data .394 .400 .300 2.7 Terminal 1 Terminal 8 .106 4-1.1 dia. 2.7

Summary of the content on the page No. 5

AQ-C NOTE When used for the load less than rated In case the dummy resistor is not used, • Characteristics of residual voltage In the case of the load current less than keep in mind that the residual voltage vs. load impedance rated, malfunction may result from the becomes as follows: 100 f = 60 Hz residual voltage across the both ends of Example: Ve: Residual voltage the load even if the solid state relay is For the inductive load by the 5 mA load V: Power voltage 80 turned off. current and t


Alternative user manuals
# User manual Category Download
1 Panasonic 2SA1738 User manual Network Card 0
2 Panasonic 2SA1790J User manual Network Card 0
3 Panasonic 2SA1790G User manual Network Card 0
4 Panasonic 2SA1791G User manual Network Card 0
5 Panasonic 2SA1532G User manual Network Card 0
6 Panasonic 2SA1739 User manual Network Card 0
7 Panasonic 2SA1309A User manual Network Card 0
8 Panasonic 2SA1748 User manual Network Card 0
9 Panasonic 2SA2009G User manual Network Card 0
10 Panasonic 2SA2028 User manual Network Card 0
11 Panasonic 2SA1532 User manual Network Card 0
12 Panasonic 2SA2021G User manual Network Card 0
13 Panasonic 2SA2078 User manual Network Card 0
14 Panasonic 2SA2079 User manual Network Card 0
15 Panasonic 2SB1321A User manual Network Card 0
16 Sony BTA-NW1A User manual Network Card 2
17 Sony BKMW-E3000 User manual Network Card 2
18 Sony AC-SQ950D User manual Network Card 0
19 Sony BBV RX100 User manual Network Card 3
20 Sony CLIE A-AVZ-100-11 User manual Network Card 1