Omnitron Systems Technology iConverter GX/TM user manual

User manual for the device Omnitron Systems Technology iConverter GX/TM

Device: Omnitron Systems Technology iConverter GX/TM
Category: Network Card
Manufacturer: Omnitron Systems Technology
Size: 0.65 MB
Added : 11/28/2013
Number of pages: 48
Print the manual

Download

How to use this site?

Our goal is to provide you with a quick access to the content of the user manual for Omnitron Systems Technology iConverter GX/TM. Using the online preview, you can quickly view the contents and go to the page where you will find the solution to your problem with Omnitron Systems Technology iConverter GX/TM.

For your convenience

If looking through the Omnitron Systems Technology iConverter GX/TM user manual directly on this website is not convenient for you, there are two possible solutions:

  • Full Screen Viewing - to easily view the user manual (without downloading it to your computer), you can use full-screen viewing mode. To start viewing the user manual Omnitron Systems Technology iConverter GX/TM on full screen, use the button Fullscreen.
  • Downloading to your computer - You can also download the user manual Omnitron Systems Technology iConverter GX/TM to your computer and keep it in your files. However, if you do not want to take up too much of your disk space, you can always download it in the future from ManualsBase.
Omnitron Systems Technology iConverter GX/TM User manual - Online PDF
Advertisement
« Page 1 of 48 »
Advertisement
Print version

Many people prefer to read the documents not on the screen, but in the printed version. The option to print the manual has also been provided, and you can use it by clicking the link above - Print the manual. You do not have to print the entire manual Omnitron Systems Technology iConverter GX/TM but the selected pages only. paper.

Summaries

Below you will find previews of the content of the user manuals presented on the following pages to Omnitron Systems Technology iConverter GX/TM. If you want to quickly view the content of pages found on the following pages of the manual, you can use them.

Abstracts of contents
Summary of the content on the page No. 1

®
iConverter GX/TM Media Converter
and
Network Interface Device
STANDALONE AND PLUG-IN MODULE
USER MANUAL
Release 3.4

Summary of the content on the page No. 2

Table of Contents 1.0 Overview ....................................................................................................................3 1.1 General Description....................................................................................................3 1.1.1 Advanced Features ....................................................................................................3 2.0 Port Structure .................................................................................

Summary of the content on the page No. 3

1.0 OVERVIEW This document describes the installation and configuration of the iConverter GX/TM standalone Network Interface Device and plug-in modules. The difference between the module types are indicated using the following legend throughout this User Manual: SA - Standalone PI - Plug-In 1.1 GENERAL DESCRIPTION ® The Omnitron iConverter GX/TM is a carrier-class media converter and a Network Interface Device (NID) that provides 10BASE-T, 100BASE-TX or 1000BASE-T (10/100/1000) to 1000BASE-X Fi

Summary of the content on the page No. 4

2.0 PORT STRUCTURE 2.1 OVERVIEW The front panel of the GX/TM provides access to the management (serial console), UTP and fiber ports. The fiber port will vary depending on the connector type; ST, SC, MT-RJ, LC or SFP supporting 1000BASE-FX transceivers. The plug-in module features two additional Ethernet ports for connectivity via the chassis backplane. 2.1.1 Management Port PI SA The GX/TM features a Serial RS-232 Console Port (aka Craft Interface) which can be connected to a computer for

Summary of the content on the page No. 5

19-Module Chassis 5-Module Chassis 2-Module Chassis 1-Module Redundant Chassis 3.0 INSTALLATION PROCEDURE 3.1 OVERVIEW The following steps outline the installation and configuration procedures for the GX/TM. Refer to the specified sections for detailed instructions. • Configure DIP-switches (Section 3.2) • Installing the Module and Connecting Cables (Section 3.3) • Configure Module via Command Line Interface (Section 3.4) • Verify Operation (Section 3.5) When the setup and configuration pr

Summary of the content on the page No. 6

3.2 CONFIGURING DIP-SWITCHES PI SA The GX/TM plug-in module has two board-mounted DIP-switches. The standalone unit has one bank of DIP-switches. The locations of the DIP-switches are illustrated below. DIP-switch Locations 3.2.1 Board-Mounted Bank 1 Settings PI SA DIP-switch Bank 1 is available on both the plug-in and standalone modules. The table indicates the position of the switch; Left/Down or Right/Up. As indicated in the DIP-switch location diagram, Left and Right refers to

Summary of the content on the page No. 7

NOTE: When the fiber optic port operates in Auto-Negotiation mode, the port advertises for Pause. When the fiber optic port operates in Manual mode, Pause is disabled. NOTE: The fiber optic port of the GX/TM works in Full-Duplex mode in both Auto and Manual Negotiation modes. 3.2.1.2 SW2 - UTP Auto/Manual Negotiation “AN/Man” When this DIP-switch is in the “AN” position (factory default), the UTP port automatically determines the Speed, Duplex and Pause mode of the connecting UTP device. If

Summary of the content on the page No. 8

3.2.1.3 SW3 - UTP Speed Gigabit/10-100 “1000/10-100” When the “1000/10-100” DIP-switch is in the “1000” position (factory default), the UTP always operates in 10/100/1000Mbps Auto-Negotiation mode. The UTP port auto-negotiates to a speed of 10Mbps, 100Mbps or 1000Mbps with the connected UTP device. In this mode, the UTP “AN/Man” and UTP “100/10” DIP- switches have no effect. When the “1000/10-100” DIP-switch is in the UP 10/100Mbps “10-100” position and the UTP “AN/Man” DIP-switch is in the “Man

Summary of the content on the page No. 9

3.2.2 Board-Mounted Bank 2 Settings PI SA DIP-switch Bank 2 is available on both the plug-in and standalone modules. PI SA Switch Left (Factory Default) Right Switch Down (Factory Default) Up SW1 A-DS: Port A Disabled A-EN: Port A Enabled SW3 Off: Pause: Pause Disable Pause Enable SW2 B-DS: Port B Disabled B-EN: Port B Enabled SW4 Reserved Reserved SW3 Off: Pause: SW5 Auto: Man: Pause Disable Pause Enable UTP Auto Crossover UTP Manual Crossover SW4 M/SL: SL: Master/Slave Auto-Select Slave-Mo

Summary of the content on the page No. 10

3.2.2.5 SW5 - UTP 10/100 Auto/Manual Crossover “AX/MANX” The GX/TM features 10/100 Auto Crossover, which allows it to connect to a switch or a workstation with either straight-through or Crossover UTP cables. The 10/100 Auto Crossover feature is only available when the UTP port is operating in Auto-Negotiation mode. The UTP port operates in Auto-Negotiation mode when the “AN/Man” DIP-switch is in the Auto- Negotiate “AN” position, or when the “1000/10-100” DIP-switch is in the Gigabit “1000” po

Summary of the content on the page No. 11

3.3 INSTALLING PLUG-IN MODULES AND CONNECTING CABLES PI a. Carefully slide the module into an open slot in the chassis. Align the module with the installation guides and ensure that the module is firmly seated against the backplane. Secure the module by fastening the front panel thumbscrew (push in and turn clockwise to tighten) to the chassis front. Verify the “Pwr” LED is ON (indicating the chassis is powered). SA a. The GX/TM standalone Network Interface Device (NID) is available in tableto

Summary of the content on the page No. 12

3.4 CONFIGURE THE MODULE VIA COMMAND LINE INTERFACE PI SA To configure, attach the GX/TM to a DB-9 serial (RS-232) equipped computer with terminal emulation software such as HyperTerminal. The GX/TM Serial Console Port (DCE) is a mini DIN-6 female connector which can be changed to a DB-9 connector with the included adapter (Part #8082-0). Attach the ends of a serial cable to the serial port of the PC and the Serial Console Port of the GX/TM. This is a standard asynchronous serial interface

Summary of the content on the page No. 13

The Management Options screen will be displayed. PI SA Management Options iConverter, Serial Agent Network Management 1: Chassis and Module Management 2: Set Module Identifier Management Module Preferences 3: IP and Control Preferences 4: SNMP Preferences 5: Abandon Preference Changes 6: Save Preference Changes 7: Restore to Factory Defaults 8: Restart Management Module 9: Other Networking Features Management Module Maintenance 10: Firmware Update 11: Set Date/Time IP Add

Summary of the content on the page No. 14

3.4.1 Setting IP and Control Preferences An IP address is required for the SNMP manager to address the GX/TM. The factory default setting is 192.168.1.220. The IP address can be configured manually or automatically as a DHCP client. 3.4.1.1 Setting IP Parameters Manually To manually configure the IP address and control parameters, select 3 from the Management Options screen. The IP and Control Preferences screen will appear. PI SA IP and Control Preferences Screen iConverter, Serial Agent 1:

Summary of the content on the page No. 15

3.4.1.2 Setting IP Parameters as DHCP Client To configure the IP automatically as a DHCP client, select 9 from the Management Options screen. The Other Networking Features screen will appear. PI SA Management Options iConverter, Serial Agent Network Management 1: Chassis and Module Management 2: Set Module Identifier Management Module Preferences 3: IP and Control Preferences 4: SNMP Preferences 5: Abandon Preference Changes 6: Save Preference Changes 7: Restore to Factory Defau

Summary of the content on the page No. 16

To set the Chassis Number, select 4 at the IP and Control Preferences screen, press and follow the instructions to enter the chassis number. To set the Chassis Name, select 5 at the IP and Control Preferences screen, press and follow the instructions to enter the chassis name. NOTE: When the NMM is installed into the chassis and is set to Remote OAM, the chassis number of the GX/TM is automatically assigned by the NMM. PI SA IP and Control Preferences Screen iConverter, Serial A

Summary of the content on the page No. 17

PI SA IP and Control Preferences Screen iConverter, Serial Agent 1: Set IP 192.168.1.220 2: Set Subnet Mask 255.255.255.0 3: Set Gateway 192.168.1.1 4: Chassis Number 1 5: Chassis Name (also sysName) GX/TM 6: Enable/Disable TELNET Enabled 7: Enable/Disable FTP Disabled 8: Enable/Disable Soft Switch Reload Disabled 9: TELNET Password ***** 10: FTP Password 11: Serial Password Enter Choice, Management Options Screen(0), (H)elp, E(x)it > To save the new values, select 0 and

Summary of the content on the page No. 18

PI SA SNMP Preferences Screen iConverter, Serial Agent Chassis Number = 1 SNMP Engine ID 80001CAE03000687003B19 1: sysContact Omnitron (949) 250-6510 2: sysLocation Irvine, CA USA 3: SNMP Writes Enabled SNMP v1/v2c ------------------------------------------------------------------- 4: Read Community ***** 5: Write Community ***** 6: Agent Enabled SNMP V3 -----------------------------------------------------------------------

Summary of the content on the page No. 19

To set User 1 security, select 10 at the SNMP Preferences screen, press and then follow the screen prompts. To set the User 2 security, select 13 at the SNMP Preferences screen, press and then follow the screen prompts. To set User 1 privacy password, select 11 at the SNMP Preferences screen, press and then follow the screen prompts. To set the User 2 privacy password, select 14 at the SNMP Preferences screen, press and then follow the screen prompts. To set Use

Summary of the content on the page No. 20

3.4.3 Management Processor VLAN Support The GX/TM Management Processor can independently transmit and receive Management Data with an IEEE 802.1Q tag. To enable and configure this feature, type 9 from the Management Options screen to access the Other Networking Features screen. PI SA Other Networking Features Screen iConverter, Serial Agent 1: Enable/Disable DHCP Client Disabled 2: Enable/Disable Keep Alive Trap Disabled 3: Keep Alive Trap interval (10-600 secs) 10 4: Enable/Dis


Alternative user manuals
# User manual Category Download
1 Omnitron Systems Technology E1 User manual Network Card 1
2 Omnitron Systems Technology FlexPoint 4380 User manual Network Card 1
3 Omnitron Systems Technology FlexPoint 10AUI/T User manual Network Card 1
4 Omnitron Systems Technology FlexPoint Powered Chassis 4385 User manual Network Card 0
5 Omnitron Systems Technology FlexPoint 100Fx/Tx User manual Network Card 0
6 Omnitron Systems Technology FlexPoint Powered Chassis 4386 User manual Network Card 0
7 Omnitron Systems Technology FlexPoint Powered Chassis 4389 User manual Network Card 0
8 Omnitron Systems Technology FlexPoint TR User manual Network Card 0
9 Omnitron Systems Technology FlexPoint 10FL/2 User manual Network Card 1
10 Omnitron Systems Technology iConverter 10FL/T User manual Network Card 1
11 Omnitron Systems Technology iConverter 10/100VT User manual Network Card 0
12 Omnitron Systems Technology iConverter 10T/2 User manual Network Card 0
13 Omnitron Systems Technology iConverter 2FXM2 User manual Network Card 1
14 Omnitron Systems Technology iConverter 2GXM User manual Network Card 0
15 Omnitron Systems Technology iConverter 2Tx User manual Network Card 0
16 Sony BTA-NW1A User manual Network Card 2
17 Sony BKMW-E3000 User manual Network Card 2
18 Sony AC-SQ950D User manual Network Card 0
19 Sony BBV RX100 User manual Network Card 3
20 Sony CLIE A-AVZ-100-11 User manual Network Card 1