National Instruments PXI Terminal Block NI TB-2708 user manual

User manual for the device National Instruments PXI Terminal Block NI TB-2708

Device: National Instruments PXI Terminal Block NI TB-2708
Category: Network Card
Manufacturer: National Instruments
Size: 0.87 MB
Added : 6/19/2014
Number of pages: 12
Print the manual

Download

How to use this site?

Our goal is to provide you with a quick access to the content of the user manual for National Instruments PXI Terminal Block NI TB-2708. Using the online preview, you can quickly view the contents and go to the page where you will find the solution to your problem with National Instruments PXI Terminal Block NI TB-2708.

For your convenience

If looking through the National Instruments PXI Terminal Block NI TB-2708 user manual directly on this website is not convenient for you, there are two possible solutions:

  • Full Screen Viewing - to easily view the user manual (without downloading it to your computer), you can use full-screen viewing mode. To start viewing the user manual National Instruments PXI Terminal Block NI TB-2708 on full screen, use the button Fullscreen.
  • Downloading to your computer - You can also download the user manual National Instruments PXI Terminal Block NI TB-2708 to your computer and keep it in your files. However, if you do not want to take up too much of your disk space, you can always download it in the future from ManualsBase.
National Instruments PXI Terminal Block NI TB-2708 User manual - Online PDF
Advertisement
« Page 1 of 12 »
Advertisement
Print version

Many people prefer to read the documents not on the screen, but in the printed version. The option to print the manual has also been provided, and you can use it by clicking the link above - Print the manual. You do not have to print the entire manual National Instruments PXI Terminal Block NI TB-2708 but the selected pages only. paper.

Summaries

Below you will find previews of the content of the user manuals presented on the following pages to National Instruments PXI Terminal Block NI TB-2708. If you want to quickly view the content of pages found on the following pages of the manual, you can use them.

Abstracts of contents
Summary of the content on the page No. 1

INSTALLATION GUIDE
NI TB-2708
PXI Terminal Block for S Series Devices
This installation guide describes how to install and connect signals to the
NI TB-2708 terminal block for use with PXI-6115/6120 S Series devices.
Caution The connectors of the TB-2708 are sensitive to electrostatic discharge (ESD). The
user should ground themselves and/or design watchdog timing into their application prior
to connecting or disconnecting signals.
Introduction
The TB-2708 is a terminal block assembly consist

Summary of the content on the page No. 2

The nine SMB connectors on the TB-2708 allow you to easily connect analog input and analog output signals to your National Instruments device. The 14-pin I/O connector located on the bottom of the TB-2708 allows access to digital signals. Caution The TB-2708 is not designed for input voltages greater than 42 V /60 VDC, pk even if you install a voltage divider that reduces the voltage to within the input range of the DAQ device. Input voltages greater than 42 V /60 VDC can damage the TB-2708

Summary of the content on the page No. 3

Do not substitute parts or modify equipment. Because of the danger of introducing additional hazards, do not install unauthorized parts or modify the device. Return the device to National Instruments for service and repair to ensure that its safety features are not compromised. You must insulate all of your signal connections to the highest voltage with which the TB-2708 can come in contact. Connections, including power signals to ground and vice versa, that exceed any of the maximum signal

Summary of the content on the page No. 4

To connect the terminal block to the PXI module I/O connector, refer to Figure 2 as you complete the following steps: 1. Install the PXI module into the chassis and tighten the two module screws. You must install the PXI device before connecting the TB-2708. Refer to the DAQ Getting Started Guide for instructions on installing your PXI device. 2. Guide the terminal block onto the PXI module connector. Caution Do not force the terminal block when inserting it into or removing it from the PXI

Summary of the content on the page No. 5

Table 1. TB-2708 Signal Descriptions Signal Name Reference Direction Description AI <0..3> AI GND Input Analog Input channels 0 through 3. AO <0..1> AO GND Output Analog Output channels 0 and 1. PFI 0/AI Start Trig D GND Input As an input, this pin is a programmable function input (PFI). Output As an output, this pin is the AI Start Trigger signal. PFI 7/AI SAMP CLK D GND Input As an input, this pin is a PFI. Output As an output, this pin is the AI Sample Clock signal. CTR 0 OUT D GND Output

Summary of the content on the page No. 6

Measuring Floating Signals You can use the TB-2708 to measure floating and ground-referenced analog input signals. To measure floating signal sources, move the switch located under the rubber-sealed door on the enclosure cover for the AI channel you are using to the ON (floating source) switch position. In the floating source switch position, the amplifier negative terminal connects to ground through a 5 k Ω resistor in parallel with a 0.1 μF capacitor. Table 2 shows the TB-2708 switch con

Summary of the content on the page No. 7

Cabling Options This section describes the cabling options for accessing signals on the TB-2708. A 14-pin connector on the bottom of the TB-2708 provides access to digital I/O signals. Use the MFIT-Pigtail Cable Assembly (part number 194123-01) to access digital signals on the TB-2708. The MFIT-Pigtail Cable Assembly features a 14-pin I/O connector on one end and pigtail conductors on the other end. The pigtail conductors on the cable assembly can be used to terminate digital signals to th

Summary of the content on the page No. 8

Table 3. TB-2708 Wiring Information for 14-Pos MFIT-Pigtail Cable Assembly (Part Number 194123-01) (Continued) Pin Number Wire Color Signal Name 5 Orange P0.3 6 Blue CTR 0 OUT 7 White/Black GND 8 Red/Black P0.4 9 Green/Black P0.5 10 Orange/Black P0.6 11 Blue/Black P0.7 12 Drain Wire CHASSIS GND 13 Red/White CTR 1 OUT 14 Green/White PFI 9 NC Blue/White — Table 4 lists the National Instruments cables available for connecting the TB-2708 to both analog and digital user signals. Table 4. TB-2708

Summary of the content on the page No. 9

Specifications This section lists the specifications of the TB-2708. These specifications are typical at 25 °C unless otherwise specified. Input/Output Refer to the documentation for your PXI-6115/6120 S Series device to determine the input/output specifications for your application. Caution Do not apply an input voltage greater than 42 V /60 VDC to the TB-2708. Input pk voltages greater than 42 V /60 VDC can damage the TB-2708 and any device connected pk to it, including the host computer.

Summary of the content on the page No. 10

Environment The NI TB-2708 is intended for indoor use only. Operating temperature ............................0 to 55 °C Storage temperature................................–20 to 70 °C Relative humidity ...................................10 to 90% noncondensing Pollution Degree .....................................2 Safety This product is designed to meet the requirements of the following standards of safety for electrical equipment for measurement, control, and laboratory use: � IEC 61010-1,

Summary of the content on the page No. 11

National Instruments corporate headquarters is located at 11500 North Mopac Expressway, Austin, Texas, 78759-3504. National Instruments also has offices located around the world to help address your support needs. For telephone support in the United States, create your service request at ni.com/support and follow the calling instructions or dial 512 795 8248. For telephone support outside the United States, contact your local branch office: Australia 1800 300 800, Austria 43 662 457990-0,

Summary of the content on the page No. 12

National Instruments, NI, ni.com, and LabVIEW are trademarks of National Instruments Corporation. Refer to the Terms of Use section on ni.com/legal for more information about National Instruments trademarks. Other product and company names mentioned herein are trademarks or trade names of their respective companies. For patents covering National Instruments products, refer to the appropriate location: Help»Patents in your software, the patents.txt file on your CD, or ni.com/patents. © 200


Alternative user manuals
# User manual Category Download
1 National Instruments 24-Bit Half/Full-Bridge Analog Input Module NI 9237 User manual Network Card 11
2 National Instruments 700 User manual Network Card 2
3 National Instruments 370620B-01 User manual Network Card 0
4 National Instruments 5411 User manual Network Card 0
5 National Instruments 6508 PCI-DIO-96 User manual Network Card 1
6 National Instruments 8-Channel Solid-State Relay (SSR) Digital Output NI 9485 User manual Network Card 6
7 National Instruments 8330 Series User manual Network Card 0
8 National Instruments AT E Series User manual Network Card 4
9 National Instruments BNC-2140 User manual Network Card 0
10 National Instruments 374318A-01 User manual Network Card 0
11 National Instruments Cabled PCI Express User manual Network Card 0
12 National Instruments AutoCode NI MATRIX User manual Network Card 1
13 National Instruments cFP-20xx User manual Network Card 0
14 National Instruments DAQCard-1200 User manual Network Card 6
15 National Instruments Data Acquisition Device NI USB-621x User manual Network Card 10
16 Sony BTA-NW1A User manual Network Card 2
17 Sony BKMW-E3000 User manual Network Card 2
18 Sony AC-SQ950D User manual Network Card 0
19 Sony BBV RX100 User manual Network Card 3
20 Sony CLIE A-AVZ-100-11 User manual Network Card 1