National Instruments PXI Terminal Block NI TB-2709 user manual

User manual for the device National Instruments PXI Terminal Block NI TB-2709

Device: National Instruments PXI Terminal Block NI TB-2709
Category: Network Card
Manufacturer: National Instruments
Size: 0.86 MB
Added : 6/19/2014
Number of pages: 12
Print the manual

Download

How to use this site?

Our goal is to provide you with a quick access to the content of the user manual for National Instruments PXI Terminal Block NI TB-2709. Using the online preview, you can quickly view the contents and go to the page where you will find the solution to your problem with National Instruments PXI Terminal Block NI TB-2709.

For your convenience

If looking through the National Instruments PXI Terminal Block NI TB-2709 user manual directly on this website is not convenient for you, there are two possible solutions:

  • Full Screen Viewing - to easily view the user manual (without downloading it to your computer), you can use full-screen viewing mode. To start viewing the user manual National Instruments PXI Terminal Block NI TB-2709 on full screen, use the button Fullscreen.
  • Downloading to your computer - You can also download the user manual National Instruments PXI Terminal Block NI TB-2709 to your computer and keep it in your files. However, if you do not want to take up too much of your disk space, you can always download it in the future from ManualsBase.
National Instruments PXI Terminal Block NI TB-2709 User manual - Online PDF
Advertisement
« Page 1 of 12 »
Advertisement
Print version

Many people prefer to read the documents not on the screen, but in the printed version. The option to print the manual has also been provided, and you can use it by clicking the link above - Print the manual. You do not have to print the entire manual National Instruments PXI Terminal Block NI TB-2709 but the selected pages only. paper.

Summaries

Below you will find previews of the content of the user manuals presented on the following pages to National Instruments PXI Terminal Block NI TB-2709. If you want to quickly view the content of pages found on the following pages of the manual, you can use them.

Abstracts of contents
Summary of the content on the page No. 1

INSTALLATION GUIDE
NI TB-2709
PXI Terminal Block for S Series Devices
This installation guide describes how to install and connect signals to the
NI TB-2709 terminal block for use with PXI-6123/6133 S Series devices.
The TB-2709 can also be used with the PXI-6122/6132 devices to access
the first four AI channels.
Introduction
The TB-2709 is a terminal block assembly consisting of nine SMB
connectors and a 14-pin I/O connector. The terminal block assembly
connects directly to the front panel

Summary of the content on the page No. 2

The nine SMB connectors on the TB-2709 allow you to easily connect analog input signals to your National Instruments device. The 14-pin I/O connector located on the bottom of the TB-2709 allows access to digital signals. Caution The TB-2709 is not designed for input voltages greater than 42 V /60 VDC, pk even if you install a voltage divider that reduces the voltage to within the input range of the DAQ device. Input voltages greater than 42 V /60 VDC can damage the TB-2709, any pk device c

Summary of the content on the page No. 3

Do not substitute parts or modify equipment. Because of the danger of introducing additional hazards, do not install unauthorized parts or modify the device. Return the device to National Instruments for service and repair to ensure that its safety features are not compromised. You must insulate all of your signal connections to the highest voltage with which the TB-2709 can come in contact. Connections, including power signals to ground and vice versa, that exceed any of the maximum signal

Summary of the content on the page No. 4

To connect the terminal block to the PXI module I/O connector, refer to Figure 2 as you complete the following steps: 1. Install the PXI module into the chassis and tighten the two module screws. You must install the PXI device before connecting the TB-2709. Refer to the DAQ Getting Started Guide for instructions on installing your PXI device. 2. Guide the terminal block onto the PXI module connector. Caution Do not force the terminal block when inserting it into or removing it from the PXI

Summary of the content on the page No. 5

Front Panel DAQ Device SMB Connectors Signals AI <0..7> + AI <0..7> – 5 kΩ AI <0..7> GND 0.1 μF AI Start Trig D GND Figure 4. NI TB-2709 Block Diagram Table 1. TB-2709 Signal Descriptions Signal Name Reference Direction Description AI <0..7> AI GND Input Analog Input channels 0 through 7. PFI 0/AI Start Trig D GND Input As an input, this pin is a programmable function input (PFI). Output As an output, this pin is the AI Start Trigger signal. For more detailed descriptions of these signals, r

Summary of the content on the page No. 6

Table 2. Configuration Summary Signal Source Types for S Series Devices TB-2709 Switch Configuration Floating Source Ground-Referenced Source Floating Source DAQ Device DAQ Device (Differential Input (Differential Input Signal Mode) Signal TB-2709 TB-2709 Mode) Source Source + + + – + – – – AI GND AI GND Recommended Not Recommended Ground- DAQ Device DAQ Device Referenced Source (Differential Input (Differential Input Signal Signal Mode) TB-2709 TB-2709 Mode) Source Source + + + + – – – – AI G

Summary of the content on the page No. 7

conductors on the other end. The pigtail conductors on the cable assembly can be used to terminate digital signals to the connector(s) your application requires. Figure 5 and Table 3 list the pin assignments and wiring information necessary for connecting the TB-2709 to DIO signals. GND 7 14 PFI 9 CTR 0 OUT 6 13 CTR 1 OUT P0.3 5 12 CHASSIS GND Pin 7 Pin 14 P0.2 4 11 P0.7 10 P0.1 3 P0.6 9 P0.0 2 P0.5 8 GND 1 P0.4 Pin 1 Pin 8 Figure 5. 14-Pin Digital I/O Connector Table 3. TB-2709 Wiring I

Summary of the content on the page No. 8

Table 3. TB-2709 Wiring Information for 14-Pos MFIT-Pigtail Cable Assembly (Part Number 194123-01) (Continued) Pin Number Wire Color Signal Name 9 White/Black P0.5 10 White/Brown P0.6 11 White/Red P0.7 12 Drain Wire CHASSIS GND 13 White/Orange CTR 1 OUT 14 White/Yellow PFI 9 Table 4 lists the National Instruments cables available for connecting the TB-2709 to both analog and digital user signals. Table 4. TB-2709 Cabling Options Cable Length Part Number SMB-100, SMB Female to BNC 0.6 m 76338

Summary of the content on the page No. 9

Physical Dimensions Height.............................................. 10.7 × 8.6 × 2.0 cm (4.2 × 3.4 × 0.8 in.) Weight............................................. 144.6 g (5.1 oz) I/O connectors 68-position SCSI-II type................. 1, female SMB jacks....................................... 9 14-pin auxiliary connector .............. One, Molex 14-pin microfit connector Shock and Vibration Operational shock .................................. 30 g peak, half-sine, 11 ms pulse (Tested in

Summary of the content on the page No. 10

Safety This product is designed to meet the requirements of the following standards of safety for electrical equipment for measurement, control, and laboratory use: � IEC 61010-1, EN 61010-1 � UL 61010-1, CSA 61010-1 Note For UL and other safety certifications, refer to the product label, or visit ni.com/ certification, search by model number or product line, and click the appropriate link in the Certification column. Waste Electrical and Electronic Equipment (WEEE) EU Customers At the end of

Summary of the content on the page No. 11

Finland 385 (0) 9 725 72511, France 33 (0) 1 48 14 24 24, Germany 49 89 7413130, India 91 80 41190000, Israel 972 3 6393737, Italy 39 02 413091, Japan 81 3 5472 2970, Korea 82 02 3451 3400, Lebanon 961 (0) 1 33 28 28, Malaysia 1800 887710, Mexico 01 800 010 0793, Netherlands 31 (0) 348 433 466, New Zealand 0800 553 322, Norway 47 (0) 66 90 76 60, Poland 48 22 3390150, Portugal 351 210 311 210, Russia 7 495 783 6851, Singapore 1800 226 5886, Slovenia 386 3 425 42 00, South Africa 27 0 11

Summary of the content on the page No. 12

National Instruments, NI, ni.com, and LabVIEW are trademarks of National Instruments Corporation. Refer to the Terms of Use section on ni.com/legal for more information about National Instruments trademarks. Other product and company names mentioned herein are trademarks or trade names of their respective companies. For patents covering National Instruments products, refer to the appropriate location: Help»Patents in your software, the patents.txt file on your CD, or ni.com/patents. © 200


Alternative user manuals
# User manual Category Download
1 National Instruments 24-Bit Half/Full-Bridge Analog Input Module NI 9237 User manual Network Card 11
2 National Instruments 700 User manual Network Card 2
3 National Instruments 370620B-01 User manual Network Card 0
4 National Instruments 5411 User manual Network Card 0
5 National Instruments 6508 PCI-DIO-96 User manual Network Card 1
6 National Instruments 8-Channel Solid-State Relay (SSR) Digital Output NI 9485 User manual Network Card 6
7 National Instruments 8330 Series User manual Network Card 0
8 National Instruments AT E Series User manual Network Card 4
9 National Instruments BNC-2140 User manual Network Card 0
10 National Instruments 374318A-01 User manual Network Card 0
11 National Instruments Cabled PCI Express User manual Network Card 0
12 National Instruments AutoCode NI MATRIX User manual Network Card 1
13 National Instruments cFP-20xx User manual Network Card 0
14 National Instruments DAQCard-1200 User manual Network Card 6
15 National Instruments Data Acquisition Device NI USB-621x User manual Network Card 10
16 Sony BTA-NW1A User manual Network Card 2
17 Sony BKMW-E3000 User manual Network Card 2
18 Sony AC-SQ950D User manual Network Card 0
19 Sony BBV RX100 User manual Network Card 3
20 Sony CLIE A-AVZ-100-11 User manual Network Card 1