National Instruments NI 9481E user manual

User manual for the device National Instruments NI 9481E

Device: National Instruments NI 9481E
Category: Network Card
Manufacturer: National Instruments
Size: 0.32 MB
Added : 6/19/2014
Number of pages: 16
Print the manual

Download

How to use this site?

Our goal is to provide you with a quick access to the content of the user manual for National Instruments NI 9481E. Using the online preview, you can quickly view the contents and go to the page where you will find the solution to your problem with National Instruments NI 9481E.

For your convenience

If looking through the National Instruments NI 9481E user manual directly on this website is not convenient for you, there are two possible solutions:

  • Full Screen Viewing - to easily view the user manual (without downloading it to your computer), you can use full-screen viewing mode. To start viewing the user manual National Instruments NI 9481E on full screen, use the button Fullscreen.
  • Downloading to your computer - You can also download the user manual National Instruments NI 9481E to your computer and keep it in your files. However, if you do not want to take up too much of your disk space, you can always download it in the future from ManualsBase.
National Instruments NI 9481E User manual - Online PDF
Advertisement
« Page 1 of 16 »
Advertisement
Print version

Many people prefer to read the documents not on the screen, but in the printed version. The option to print the manual has also been provided, and you can use it by clicking the link above - Print the manual. You do not have to print the entire manual National Instruments NI 9481E but the selected pages only. paper.

Summaries

Below you will find previews of the content of the user manuals presented on the following pages to National Instruments NI 9481E. If you want to quickly view the content of pages found on the following pages of the manual, you can use them.

Abstracts of contents
Summary of the content on the page No. 1

OPERATING INSTRUCTIONS AND SPECIFICATIONS
NI 9481E
4-Channel SPST Electromechanical Relay Module

Summary of the content on the page No. 2

This document describes how to use the National Instruments 9481E and includes dimensions, terminal assignments, and specifications for the NI 9481E. Visit ni.com/info and enter rdsoftwareversion to determine which software you need for the modules you are using. For information about installing, configuring, and programming the system, refer to the system documentation. Visit ni.com/info and enter cseriesdoc for information about C Series documentation. Caution National Instruments makes

Summary of the content on the page No. 3

NI 9481E Dimensions The following figure shows the dimensions of the NI 9481E. 73.4 (2.89) 0.0 (0.00) Figure 1. NI 9481E Dimensions in Millimeters (Inches) © National Instruments Corp. 3 NI 9481E Operating Instructions and Specifications 0.0 (0.00) 26.7 (1.05) 58.4 (2.30) 66.0 (2.60)

Summary of the content on the page No. 4

Connecting the NI 9481E The NI 9481E has a 10-terminal detachable screw-terminal connector that provides connections for four electromechanical relay channels. 0 3 CH0a 0 CH0b 1 CH1a 2 CH1b 3 CH2a 4 CH2b 5 CH3a 6 CH3b 7 NC 8 NC 9 Figure 2. NI 9481E Terminal Assignments NI 9481E Operating Instructions and Specifications 4 ni.com

Summary of the content on the page No. 5

Each electromechanical relay channel has two interchangeable terminals, CHa and CHb. Each channel has an LED that indicates the state of the channel. When a channel LED is lit, the channel is on. When the LED is dark, the channel is off. The LEDs are disabled when the chassis is in sleep mode. Refer to the Sleep Mode section for more information about sleep mode. When connecting a load to the NI 9481E, connect the positive lead of the load to either the CHa or the CHb terminal, and the gr

Summary of the content on the page No. 6

Note You must use 2-wire ferrules to create a secure connection when connecting more than one wire to a single terminal on the NI 9481E. When the channel is turned on, the terminal connected to the load drives current or applies voltage to the load. When the channel is off, the terminal does not drive current or apply voltage to the load. Sleep Mode This module supports a low-power sleep mode. Support for sleep mode at the system level depends on the chassis that the module is plugged int

Summary of the content on the page No. 7

Specifications The following specifications are typical for the range –40 to 85 °C unless otherwise noted. Output Characteristics Number of channels..........................4 electromechanical relay channels Relay type .........................................Single pole single throw (SPST) Power-on output state .......................Channels off Switching capacity (resistive load) Switching voltage.......................60 VDC max, 250 V max rms Switching current, per channel One channel on

Summary of the content on the page No. 8

Resistance per channel, channel on.........................................50 mΩ Switching rate ...................................1 operation per second Relay release time.............................5 ms max Relay operate time ............................10 ms max Relay bounce time ............................3 ms Off state leakage ...............................10 μAmax Life expectancy Mechanical (no load)..................20,000,000 operations Electrical (connecting to load) ...100,000 oper

Summary of the content on the page No. 9

Power Requirements Power consumption from chassis Active mode ...............................580 mW max Sleep mode .................................5 mW max Thermal dissipation (at 70 °C) Active mode ...............................1.5 W max Sleep mode .................................5 mW max Physical Characteristics Use a dry, low-velocity stream of air to clean the module. If needed, use a soft-bristle brush for cleaning around components. Screw-terminal wiring ......................12 to 24

Summary of the content on the page No. 10

Safety Safety Voltages Connect only voltages that are within the following limits. max, CHa-to-CHb......................................250 V rms Measurement Category II Measurement Category II is for measurements performed on circuits directly connected to the electrical distribution system. This category refers to local-level electrical distribution, such as that provided by a standard wall outlet, for example, 115 V for U.S. or 230 V for Europe. Caution Do not connect the NI 9481E to si

Summary of the content on the page No. 11

Channel-to-earth ground Continuous ...........................250 V rms (Double insulation) Withstand ............................. 2,300 V , verified by a 5 s rms dielectric withstand test Safety Standards This product meets the requirements of the following standards of safety for electrical equipment for measurement, control, and laboratory use when installed in a suitable enclosure: � IEC 61010-1, EN 61010-1 � UL 61010-1, CSA 61010-1 Note For UL and other safety certifications, refer to t

Summary of the content on the page No. 12

Environmental National Instruments C Series modules are intended for indoor use only but may be used outdoors if installed in a suitable enclosure. Refer to the manual for the chassis you are using for more information about meeting these specifications. Operating temperature (IEC 60068-2-1, IEC 60068-2-2) .....–40 to 85 °C Storage temperature (IEC 60068-2-1, IEC 60068-2-2) .....–40 to 85 °C Operating humidity (IEC 60068-2-56)..............................10 to 90% RH, noncondensing Storage

Summary of the content on the page No. 13

Environmental Management NI is committed to designing and manufacturing products in an environmentally responsible manner. NI recognizes that eliminating certain hazardous substances from our products is beneficial to the environment and to NI customers. For additional environmental information, refer to the NI and the Environment Web page at ni.com/environment. This page contains the environmental regulations and directives with which NI complies, as well as other environmental informatio

Summary of the content on the page No. 14

RoHS National Instruments (RoHS) National Instruments RoHS ni.com/environment/rohs_china (For information ni.com/ about China RoHS compliance, go to environment/rohs_china.) Where to Go for Support The National Instruments Web site is your complete resource for technical support. At ni.com/support you have access to everything from troubleshooting and application development self-help resources to email and phone assistance from NI Application Engineers. Na

Summary of the content on the page No. 15

telephone support outside the United States, contact your local branch office: Australia 1800 300 800, Austria 43 662 457990-0, Belgium 32 (0) 2 757 0020, Brazil 55 11 3262 3599, Canada 800 433 3488, China 86 21 5050 9800, Czech Republic 420 224 235 774, Denmark 45 45 76 26 00, Finland 358 (0) 9 725 72511, France 01 57 66 24 24, Germany 49 89 7413130, India 91 80 41190000, Israel 972 3 6393737, Italy 39 02 413091, Japan 81 3 5472 2970, Korea 82 02 3451 3400, Lebanon 961 (0) 1 33 28 28,

Summary of the content on the page No. 16

National Instruments, NI, ni.com, and LabVIEW are trademarks of National Instruments Corporation. Refer to the Terms of Use section onni.com/legal for more information about National Instruments trademarks. Other product and company names mentioned herein are trademarks or trade names of their respective companies. For patents covering National Instruments products/technology, refer to the appropriate location: Help»Patents in your software, the patents.txt file on your media, or the Nationa


Alternative user manuals
# User manual Category Download
1 National Instruments 24-Bit Half/Full-Bridge Analog Input Module NI 9237 User manual Network Card 11
2 National Instruments 700 User manual Network Card 2
3 National Instruments 370620B-01 User manual Network Card 0
4 National Instruments 5411 User manual Network Card 0
5 National Instruments 6508 PCI-DIO-96 User manual Network Card 1
6 National Instruments 8-Channel Solid-State Relay (SSR) Digital Output NI 9485 User manual Network Card 6
7 National Instruments 8330 Series User manual Network Card 0
8 National Instruments AT E Series User manual Network Card 4
9 National Instruments BNC-2140 User manual Network Card 0
10 National Instruments 374318A-01 User manual Network Card 0
11 National Instruments Cabled PCI Express User manual Network Card 0
12 National Instruments AutoCode NI MATRIX User manual Network Card 1
13 National Instruments cFP-20xx User manual Network Card 0
14 National Instruments DAQCard-1200 User manual Network Card 6
15 National Instruments Data Acquisition Device NI USB-621x User manual Network Card 10
16 Sony BTA-NW1A User manual Network Card 2
17 Sony BKMW-E3000 User manual Network Card 2
18 Sony AC-SQ950D User manual Network Card 0
19 Sony BBV RX100 User manual Network Card 3
20 Sony CLIE A-AVZ-100-11 User manual Network Card 1