Summary of the content on the page No. 1
™
FieldPoint FP-3000
Network Module User Manual
FieldPoint FP-3000 User Manual
January 1999 Edition
Part Number 322169A-01
Summary of the content on the page No. 2
Worldwide Technical Support and Product Information http://www.natinst.com National Instruments Corporate Headquarters 11500 North Mopac Expressway Austin, Texas 78759-3504 USA Tel: 512 794 0100 Worldwide Offices Australia 03 9879 5166, Austria 0662 45 79 90 0, Belgium 02 757 00 20, Brazil 011 284 5011, Canada (Ontario) 905 785 0085, Canada (Québec) 514 694 8521, Denmark 45 76 26 00, Finland 09 725 725 11, France 0 1 48 14 24 24, Germany 089 741 31 30, Hong Kong 2645 3186, India 91805275406,
Summary of the content on the page No. 3
Important Information Warranty The FieldPoint FP-3000 network module is warranted against defects in materials and workmanship for a period of one year from the date of shipment, as evidenced by receipts or other documentation. National Instruments will, at its option, repair or replace equipment that proves to be defective during the warranty period. This warranty includes parts and labor. The media on which you receive National Instruments software are warranted not to fail to execute pro
Summary of the content on the page No. 4
Contents About This Manual Conventions ...................................................................................................................xv Related Documentation..................................................................................................xv Chapter 1 FP-3000 Network Module Overview Overview of the FP-3000 Network Module ..................................................................1-1 Features of the FP-3000 Network Module ...............................
Summary of the content on the page No. 5
Contents Chapter 3 Example Applications Initial Power On: Assigning Address and Device Tag.................................................. 3-1 Example 1: Converting a 4–20 mA Pressure Sensor to Fieldbus Using FP-3000 ........ 3-2 Getting Started ................................................................................................ 3-2 Convert the Pressure Sensor Reading ............................................................. 3-2 Create Function Block ...........................
Summary of the content on the page No. 6
Contents Chapter 4 Block Reference Block Overview .............................................................................................................4-1 Function Blocks...............................................................................................4-1 Resource Block................................................................................................4-2 Types of Function Blocks ....................................................................................
Summary of the content on the page No. 7
Contents FP_CJC_SOURCE.......................................................................................... 4-15 FP_MOD_STATUS........................................................................................ 4-15 FP_NOISE_REJECTION ............................................................................... 4-15 FP_PWM_520_PERIOD ................................................................................ 4-16 FP_RTD_122_RANGE ..................................................
Summary of the content on the page No. 8
Contents BYPASS..........................................................................................................C-4 CHANNEL......................................................................................................C-4 CHECKBACK ................................................................................................C-4 CLR_FSTATE.................................................................................................C-5 CONFIRM_TIME ............................
Summary of the content on the page No. 9
Contents LO_PRI ........................................................................................................... C-13 LOW_CUT...................................................................................................... C-13 MANUFAC_ID .............................................................................................. C-13 MAX_NOTIFY............................................................................................... C-13 MEMORY_SIZE ......................
Summary of the content on the page No. 10
Contents WRITE_ALM..................................................................................................C-22 WRITE_LOCK................................................................................................C-22 WRITE_PRI ....................................................................................................C-22 XD_SCALE.....................................................................................................C-22 Appendix D Advanced Function Block Beha
Summary of the content on the page No. 11
Contents Figure 2-12. FP-3000 Connector Pinout.................................................................... 2-12 Figure 2-13. LEDs on the FP-3000............................................................................ 2-12 Figure 2-14. FP-3000 Firmware Update Dialog Box ................................................ 2-16 Figure 2-15. FP-3000 Search Dialog Box ................................................................. 2-17 Figure 2-16. Select FP-3000 Module Dialog Box ........
Summary of the content on the page No. 12
Contents Table C-3. Checkback States ..................................................................................C-5 Table C-4. Control Options ....................................................................................C-6 Table C-5. Feature Parameter Options ...................................................................C-8 Table C-6. Hard Types ...........................................................................................C-10 Table C-7. Operation Bitmasks ......
Summary of the content on the page No. 13
About This Manual This manual describes how to use your FieldPoint FP-3000 Network Module. Conventions The following conventions appear in this manual: » The » symbol leads you through nested menu items and dialog box options to a final action. The sequence File»Page Setup»Options directs you to pull down the File menu, select the Page Setup item, and select Options from the last dialog box. This icon denotes a note, which alerts you to important information. This icon denotes a caution, whi
Summary of the content on the page No. 14
1 FP-3000 Network Module Overview This chapter provides an overview of the FP-3000 network module. Overview of the FP-3000 Network Module The FP-3000 is an intelligent network interface and controller module that manages a bank of up to nine FieldPoint I/O modules and terminal bases. The FP-3000 network module and the terminal bases snap together to form a high-speed data bus for communications between the FP-3000 network module and any I/O modules in the bank. The FP-3000 includes an H1 F
Summary of the content on the page No. 15
Chapter 1 FP-3000 Network Module Overview 1 2 4 3 + + 5 6 – + 6 1 FP-3000 Network 3 I/O Module 5 Fieldbus Module 4 Fieldbus Trunk 6 Fieldbus Devices 2 Terminal Base Figure 1-1. Fieldbus Network Setup The FP-3000 network module provides a Fieldbus interface to conventional analog and discrete I/O devices. For example, the FP-3000 makes a 4–20 mA pressure transmitter connected to a FieldPoint 8-channel analog input module behave like a Fieldbus pressure transmitter. By using an FP-3000 networ
Summary of the content on the page No. 16
Chapter 1 FP-3000 Network Module Overview Features of the FP-3000 Network Module Function Blocks Conventional devices connected to I/O modules are made visible as Fieldbus function blocks. Function blocks are software modules which describe the fundamental elements of an I/O or control system. The FP-3000, like any FOUNDATION Fieldbus–compliant device, has one or more function blocks. The function blocks in different devices can be connected to form a distributed control system. The FP-3000
Summary of the content on the page No. 17
Chapter 1 FP-3000 Network Module Overview Interoperability The FP-3000 network module can send or receive data from any Fieldbus-compliant device. The PID block in the FP-3000 can get its input from any Fieldbus-compliant device; it can also control any Fieldbus-compliant output device. The control and I/O functionality of the FP-3000 can be configured by any Fieldbus configurator, such as the National Instruments NI-FBUS Configurator. This is possible because all of the features added by N
Summary of the content on the page No. 18
2 Installation and Configuration This chapter describes how to install device description files, mount your FieldPoint FP-3000 network module, connect the terminal bases, connect power to the network module, and connect the FP-3000 to a Fieldbus network. Install the Device Description File The Device Description file (DD) contains a list of the types of function blocks and parameters supported by the FP-3000, along with online help describing the uses of given parameters. Before you can use
Summary of the content on the page No. 19
Chapter 2 Installation and Configuration Figure 2-1. NI-FBUS Configuration Utility Dialog Box 4. Click on the DD Info button. The following dialog box appears. Figure 2-2. DD Info Dialog Box 5. Click on the Import DD button. The following dialog box appears. FieldPoint FP-3000 User Manual 2-2 © National Instruments Corporation
Summary of the content on the page No. 20
Chapter 2 Installation and Configuration Figure 2-3. Import DD Dialog Box 6. Enter the file name for the device description into the entry field, then click on OK. If the import process is successful, the following dialog box appears, indicating that the software installation is complete. Figure 2-4. fbconf Dialog Box You only need to install the DD file one time for a version of the firmware. You do not have to repeat the DD installation for each FP-3000 connected to your computer. Updati