MRV Communications EM316E3 user manual

User manual for the device MRV Communications EM316E3

Device: MRV Communications EM316E3
Category: Network Card
Manufacturer: MRV Communications
Size: 0.38 MB
Added : 5/3/2014
Number of pages: 19
Print the manual

Download

How to use this site?

Our goal is to provide you with a quick access to the content of the user manual for MRV Communications EM316E3. Using the online preview, you can quickly view the contents and go to the page where you will find the solution to your problem with MRV Communications EM316E3.

For your convenience

If looking through the MRV Communications EM316E3 user manual directly on this website is not convenient for you, there are two possible solutions:

  • Full Screen Viewing - to easily view the user manual (without downloading it to your computer), you can use full-screen viewing mode. To start viewing the user manual MRV Communications EM316E3 on full screen, use the button Fullscreen.
  • Downloading to your computer - You can also download the user manual MRV Communications EM316E3 to your computer and keep it in your files. However, if you do not want to take up too much of your disk space, you can always download it in the future from ManualsBase.
MRV Communications EM316E3 User manual - Online PDF
Advertisement
« Page 1 of 19 »
Advertisement
Print version

Many people prefer to read the documents not on the screen, but in the printed version. The option to print the manual has also been provided, and you can use it by clicking the link above - Print the manual. You do not have to print the entire manual MRV Communications EM316E3 but the selected pages only. paper.

Summaries

Below you will find previews of the content of the user manuals presented on the following pages to MRV Communications EM316E3. If you want to quickly view the content of pages found on the following pages of the manual, you can use them.

Abstracts of contents
Summary of the content on the page No. 1












EM316E3

EM316E3SF

E3 Fiber Modem
Fiber Driver Module



User’s Guide

Summary of the content on the page No. 2

Fiber Driver EM316E3 & EM316E3SF Registration Card Your name: Mr./Ms___________________________________________ Organization: ________________________Dept. __________________ Your title at organization:______________________________________ Telephone: ___________________________ Fax:__________________ Organization's full address:____________________________________ __________________________________________________________ Country:___________________________________________________ Date

Summary of the content on the page No. 3

Fiber Driver EM316E3 & EM316E3SF EM316E3 EM316E3SF E3 Fiber Modem Fiber Driver Module User’s Guide P/N: 1226006-001, REV_L PAGE 3

Summary of the content on the page No. 4

Fiber Driver EM316E3 & EM316E3SF TABLE OF CONTENTS 1 INTRODUCTION 2 HARDWARE INSTALLATION 3 TROUBLESHOOTING 4 TECHNICAL SPECIFICATIONS 5 CONTACT INFORMATION 6 GLOSSARY 7 ORDERING INFORMATION P/N: 1226006-001, REV_L PAGE 4

Summary of the content on the page No. 5

Fiber Driver EM316E3 & EM316E3SF 1 INTRODUCTION About this Manual Before unpacking please refer to section 2 (Hardware Installation) This manual is a guide to the installation and operation of the EM316E3 Fiber modem. Product description describes the product, its functions, features, protocol supported, minimum requirements, and typical applications. Customer support provides information on return policy and customer support information. Glossary provides definition to te

Summary of the content on the page No. 6

Fiber Driver EM316E3 & EM316E3SF Features • E3 conversion between coax media and fiber media • Supports ITU-T G.703, ITU-T G.823, and HDB3 standards • Supports Local, Remote and Line Loop back Test • Up to 100km Transmission on Single Mode or 7km on Multimode Fiber • Modules can be Inserted / Removed without powering off the chassis • Extensive Network Management Support when used with EM316NM *For dB budget see: ftp://ftp.fiberdriver.com/pub/doc/spec/fiberdriver Requireme

Summary of the content on the page No. 7

Fiber Driver EM316E3 & EM316E3SF Display Information (LED Definition) • PWR: illuminates when unit is powered (green color) • LPBK: illuminates (yellow color) when local loop back on both interfaces is enabled, OFF (no light or green color) when in normal mode • C: illuminates when E3 (coax) interface detected a signal above threshold level • SD: illuminates when Fiber Optic interface detected a signal above threshold level • PLL: illuminates when phase lock loop (PLL) detected enou

Summary of the content on the page No. 8

Fiber Driver EM316E3 & EM316E3SF Configuration Jumper Settings: (Factory Default) CONFIGURING THE SWITCH (S1) SWITCH SETTINGS RESULTS *ON Force switches selections (loop back) regardless of NMS command MAN/NMS OFF Default setting comes from switches after power up, but maybe change by NMS commands SEC/PRI ON/OFF Not used in this application. Reserved for the dual-redundant card. Setting is irrelevant to the card ON Loop back mode enabled LPBK/NORMA O

Summary of the content on the page No. 9

Fiber Driver EM316E3 & EM316E3SF Theory of Operation Block diagram of the Modem/Converter is shown below (fig. 1) E3 B3ZS FI Encoder Receiver Decoder Transmitter E3 B3ZS Decoder FI Receiver Transmitter Encoder Fig. 1 Fig. 1 Block Diagram of EM316DS3 E3 Line Receiver to fiber optic Transmitter: The receiver Line Interface Unit (LIU) receives the E3 signal and performs clock recovery and data detection. The data goes through B3ZS Decoding Block to ext

Summary of the content on the page No. 10

Fiber Driver EM316E3 & EM316E3SF Switch LPBK/NORM is set to OFF Loop back on E3 side Fiber side Coax to near DTE Fig. 3a: External loop back on fiber optic Switch LPBK/NORM is set to OFF Fiber side Loop back on To far EM316E3 E3 side Fig. 3b: External loop back on fiber optic Loop Back Control: By NMS command or manually by a switch Loop back can be forced regardless of management by turning switch 1 MAN/NMS to ON and switch 3 NORM/

Summary of the content on the page No. 11

Fiber Driver EM316E3 & EM316E3SF 2 HARDWARE INSTALLATION PREPARATION STEP 1 Follow all Safety Regulations 1 Eliminate static electricity in the workplace by grounding operators, equipment, and devices (components and computer boards). Grounding prevents static charge buildup and electrostatic potential differences. Transporting products in special electrostatic shielding packages avert electrical field damage. 2 An effective workplace should be outfitted with the following items: a)

Summary of the content on the page No. 12

Fiber Driver EM316E3 & EM316E3SF f) ESD protective floor or mat: The mat must be grounded through a current- limiting resistor. The floor or mat dissipates the static charge of personnel approaching the workbench. Special conductive tile or floor treatment can be used when mats are not practical or cause a safety hazard. Chairs should be conductive or grounded with a drag chain to the flooring. STEP 2 Determine the best location for the chassis. Affix the chassis to a 19” or 23” rack usi

Summary of the content on the page No. 13

Fiber Driver EM316E3 & EM316E3SF UNIT INSTALLATION STEP 1 Remove required amount of blank panels from the NC316BU-xx. NOTE: Per FCC regulations, either a panel or a module should always cover chassis slots. FIGURE 1.1 Take out the required amount of blank panels. STEP 2 Align the edges of the EM316 module to the rail inside the chassis, see pictures below. FIGURE 1.2 Align the edges of the EM316 to the rail inside the chassis and then insert the unit. P/N: 1226006-001, REV_L

Summary of the content on the page No. 14

Fiber Driver EM316E3 & EM316E3SF STEP 3 Insert the module into the NC316BU-xx unit NOTE: To avoid damaging any components on the module, handle it by the edges, using your thumb to push it securely inside the chassis. Do not use excessive force, but make sure the module is fully inserted in the chassis. When the module is correctly inserted, the PWR LED should illuminate. STEP 4 Secure the module to the unit, using the screws on the front panel. FIGURE 1.3 When the module is correctl

Summary of the content on the page No. 15

Fiber Driver EM316E3 & EM316E3SF 3 TROUBLESHOOTING The Fiber Driver series are highly reliable units. If there are any operating problems, the fault probably lies in some other aspect of the configuration. However, if after following the troubleshooting steps below (in order), you find that the unit is still not functioning correctly, please contact your local representative. Review all link LEDs to ensure that those ports you believe should be functioning are properly attached to

Summary of the content on the page No. 16

Fiber Driver EM316E3 & EM316E3SF 4 TECHNICAL SPECIFICATIONS Electrical 5VDC @ 2 Amps Max Hot Swappable Operating Temperature Range 0°C - +50 °C (32°F – 122°F) Storage temp -10°C - +60°C (14°F – 140°F) Relative Humidity 85% maximum non-condensing Emissions Compliance FCC Part 15, Subpart B, 1999 Class A CE Mark EN 50081-1: 1992 EN 50082-1: 1997 EN 55024: 1998 EN 55022: 1998 AS/NZS 3548: 1995 Physical Dimensions 1” high x 3” wide x 7” deep (2.54cm x 7.62cm

Summary of the content on the page No. 17

Fiber Driver EM316E3 & EM316E3SF 5 CUSTOMER SUPPORT Contact Information If you have any questions, please do not hesitate to contact us at: Americas Support MRV (East Coast USA) 295 Foster Street Littleton, MA 01460-2016 Tech Support: (800) 338-5316 Tech Support: (978) 952-4700 E-mail: support@fiberdriver.com Fax: (978) 952-4880 URL: http://www.fiberdriver.com MRV (West Coast USA) 20415 Nordhoff St. Chatsworth, CA 91311 Tel. (800) 338-5316 Tel. (818) 773-0900 Inter

Summary of the content on the page No. 18

Fiber Driver EM316E3 & EM316E3SF 5 GLOSSARY Complete definition of networking terms (jargon) used in this manual, may be found on our ftp site: ftp://ftp.fiberdriver.com/pub/doc/Glossary.pdf 6 ORDERING INFORMATION Please visit us at http://www.fiberdriver.com for the latest updates on our products. Fiber Driver Division of MRV Chatsworth, CA 91311 Phone: (818) 772-6235 or (800) 966-4444 Fax: (818) 772-0576 Fiber Driver Inquiries: info@fiberdriver.com Marketing:

Summary of the content on the page No. 19

Fiber Driver EM316E3 & EM316E3SF P/N: 1226006-001, REV_L PAGE 19 Place Stamp Here ------------------------------------------------ ------------------------------------------------ ------------------------------------------------ 8928 Fullbright Avenue Chatsworth, California 91311 U.S.A.


Alternative user manuals
# User manual Category Download
1 MRV Communications EM316E1 User manual Network Card 3
2 MRV Communications EM316T1 User manual Network Card 4
3 MRV Communications TERESCOPE TS700/100 User manual Network Card 14
4 MRV Communications TERESCOPE TS700/155 User manual Network Card 5
5 MRV Communications EM316E3SF User manual Network Card 1
6 MRV Communications TERESCOPE TS700/G User manual Network Card 10
7 MRV Communications TERESCOPE TS800/155 User manual Network Card 1
8 Sony BTA-NW1A User manual Network Card 2