OPERATIONS MANUAL
MiniLink® Wireless Ethernet Systems
MicroTek Electronics, Inc.
25691 Atlantic Ocean Drive, Suite B-3; Lake Forest, CA 92630
Information Hotline 888-36-MICRO
www.microtekelectronics.com
Summary of the content on the page No. 2
IMPORTANT SAFETY INSTRUCTION For your protection, please read and observe all safety instructions before operating this system and keep this sheet and any additional instructions for future reference. INSTALLATION & USE OBSERVE WARNINGS: All warnings in the operating instructions should be carefully followed. Do not make any modifications to the WEM, PIM, or any other MicroTek electronic device, as the unit will no longer comply with FCC regulations and therefore cancel its warranty. W
Summary of the content on the page No. 3
FCC Output Power Restrictions The FCC does not require licensing to implement this device. License-free operation in the industrial, scientific, and medical band is documented in FCC Rules Part 15.247. It is the responsibility of the individuals designing and implementing the radio system to assure compliance with any pertinent FCC Rules and Regulations. This device must be professionally installed. Exposure to Radio Frequency Fields The Minilink 5.8WES is designed to operate at 5.8
Summary of the content on the page No. 4
FCC REGULATORY ALERT Regulatory Alert As of July 20, 2007, a new FCC regulation has gone into effect which impacts operators of the U-NII band in the United States. As a result of this regulatory change, several MicroTek products are affected. The new FCC regulation impacts the sale of wireless equipment in the 5.25-5.35 GHz band. The regulation states that all devices imported and marketed after the th July 20 , 2007 deadline must support radar detection as specified by the FCC in th
Summary of the content on the page No. 5
Summary of the content on the page No. 6
QUICK START PROCEDURES MicroTek Electronics, Inc. recommends that all equipment be bench tested before being installed onsite. This test will ensure the equipment is functioning properly. IMPORTANT: SEE NEW FCC REGULATORY ALERT ON PAGE “( iii )” WIRELESS ETHERNET MODULE SETUP 1. Remove the Host and Client from the box, select frequency via the rotary switch at the side of the unit. (Factory set to channel 0 unless otherwise noted) The channels of each set of Host/Clients must be matc
Summary of the content on the page No. 7
PRE-INSTALLATION REMINDERS The information on the Quick Start Guide is intended for ease of use and application, the following reminders will help to ensure your satisfaction with MicroTek products and service. 1. Read through this manual before bench testing and installation 2. A helpful IP Address Locating tool is available to download from our website at http://www.microtekelectronics.com/softwaretools.htm. Download the Locator.exe tool. 3. Perform a bench test incorporating all compone
Summary of the content on the page No. 8
MINILINK WIRELESS ETHERNET SYSTEM (WES) The MiniLink WES is a plug and play CAT5/Ethernet cable replacement device. It operates in the 5.8 GHz U-NII bands on 5 non-overlapping channels. The WES system enables a wide variety of IP cameras, DVRs, encoders/decoders and web servers to be used across wireless line-of-sight links in ranges of 500 feet to 30 miles. The system operates independent of any network it may be connected to. MINILINK WIRELESS ETHERNET MODULE (WEM) WEM DESCRIPTION
Summary of the content on the page No. 9
POWER INJECTION MODULE (PIM) Note: The Power Injector Modules are not weatherproof units and must be protected from moisture. PIM DESCRIPTION A. TOP VIEW 1. ETHERNET IN – Connect to Ethernet device 2 2. POWER IN – 12-20 VDC Center Positive 1 3 3. ETHERNET OUT – Connect to Host/Client B. RIGHT SIDE VIEW 1. POWER LED – Lit when power is on 2. ETHERNET OUT – Connect to Host/Client 3. POWER IN – Connect to Power Supply 12 3 C. LEFT SIDE V
Summary of the content on the page No. 10
WES CONNECTION DIAGRAMS The following wiring schemes represent the configurations that have been tested and verified by MicroTek Electronics based on typical Ethernet wiring solutions. Other wiring configurations could be possible based on the application. A bench test is recommended to verify the designs below. A. POINT-TO-POINT SYSTEM ML ENC shown ML DEC shown 5. Power Injection Module Ethernet Out to Client 1. Client Wireless Ethernet Module 2. Host Wireless Ethernet Module
Summary of the content on the page No. 11
WEM INSTALLATION & OPERATION (cont’d) B. MOUNT DIRECTIONAL HOST/CLIENT Mount the Host/Client with the Directional WEM included wall/pole mount B-1 B-2 bracket and hardware. Connect the black mounting assembly with adjustment swivel to mounting L-shaped bracket with the ¼ - 20 button head screw. Connect the unit to the mounting assembly using the ¼-20 mounting hole in the case. Position the Host and point it in the direction of the Client (or vice- versa) and tighten the
Summary of the content on the page No. 12
Summary of the content on the page No. 13
B. MULTI-CONNECT SYSTEMS (cont’d) If you ordered a complete system with multiple Client SUs, they have been pre-configured with IP addresses as follows: ML ML WES ML WES Host AP, Client SU or Channel WES Serial IP Address Point to Point Modules Number Unit 1 05618* 192.168.1.200 WES-2500 HOST** 0 Unit 2 05619* 192.168.1.201 WES-2500 CLIENT** 0 Unit 3 05620* 192.168.1.202 WAP HOST** 0 Unit 4 05621* 192.168.1.203 WSU CLIENT** 0 Unit 5 05622* 192.168.1.205 WSU CLIENT** 0 *Ac
Summary of the content on the page No. 14
WEB PAGES (cont’d) B. STATUS – DEVICE STATUS 1. POINT-TO-POINT HOST AP The Device Status page provides the details of how the Single-Point Host is configured. The Access Point Name can be changed on the “Admin” page under the ADVANCED tab but the SSID cannot change. The updated firmware version is as shown: 7.06. One of the two jumper settings may be “on” depending on the range of the system. - 1
Summary of the content on the page No. 15
B. STATUS – DEVICE STATUS (cont’d) 2. MULTI-CONNECT HOST AP The Device Status page provides the details of how the Multipoint Host is configured. 3. CLIENT SU The Device Status page provides the details of how the Client is configured. - 11 -
Summary of the content on the page No. 16
WEB PAGES (cont’d) C. STATUS – HOST/CLIENT ASSOCIATION LISTS 1. POINT-TO-POINT AND MULTI-CONNECT HOST The Client List page of the Host AP shows the MAC address(s) of the paired or grouped Client SU(s) that are connected to the Host AP. For Point-to-Point systems, one MAC address will be shown. For Multi-connect systems, the Host AP will show all of the Client SU MAC addresses currently connected. The page will also show the Mode, Rate and RSSI communication information for each co
Summary of the content on the page No. 17
WEB PAGES (cont’d) D. STATUS – STATISTICS The Statistics page will indicate the number of transmitted and received data packets versus the number of dropped packets. - 13 -
Summary of the content on the page No. 18
WEB PAGES (cont’d) E. BASIC - WIRELESS The wireless page is used for enabling Super mode. The Super mode combines adjacent channels to provide up to 50+ Mbps of throughput. The channels available in Super mode are: 4 and 6 only. If another channel is selected, Super mode will not be enabled. To enable Super mode, click the arrow in the drop down box and select “Super A without Turbo” (30+ Mbps) or “Super A with Static Turbo” (50+ Mbps). Each Host/Client in your system will need t
Summary of the content on the page No. 19
F. BASIC – ETHERNET 1. NETWORK SETTINGS The Network Settings page is used for changing the IP Address, Subnet Mask and or Default Gateway of the Host or Client. - 15 -
Summary of the content on the page No. 20
WEB PAGES (cont’d) G. ADVANCED – ADMINISTRATION This section of the Advanced tab is used for changing the password and other administration services for the Host or Client. H. ADVANCED – SYSTEM To reboot the system and/or bring it to its default settings, visit the system page of the Advanced tab. - 16 -