LSI Ultra320 user manual

User manual for the device LSI Ultra320

Device: LSI Ultra320
Category: Network Card
Manufacturer: LSI
Size: 0.35 MB
Added : 12/7/2013
Number of pages: 46
Print the manual

Download

How to use this site?

Our goal is to provide you with a quick access to the content of the user manual for LSI Ultra320. Using the online preview, you can quickly view the contents and go to the page where you will find the solution to your problem with LSI Ultra320.

For your convenience

If looking through the LSI Ultra320 user manual directly on this website is not convenient for you, there are two possible solutions:

  • Full Screen Viewing - to easily view the user manual (without downloading it to your computer), you can use full-screen viewing mode. To start viewing the user manual LSI Ultra320 on full screen, use the button Fullscreen.
  • Downloading to your computer - You can also download the user manual LSI Ultra320 to your computer and keep it in your files. However, if you do not want to take up too much of your disk space, you can always download it in the future from ManualsBase.
LSI Ultra320 User manual - Online PDF
Advertisement
« Page 1 of 46 »
Advertisement
Print version

Many people prefer to read the documents not on the screen, but in the printed version. The option to print the manual has also been provided, and you can use it by clicking the link above - Print the manual. You do not have to print the entire manual LSI Ultra320 but the selected pages only. paper.

Summaries

Below you will find previews of the content of the user manuals presented on the following pages to LSI Ultra320. If you want to quickly view the content of pages found on the following pages of the manual, you can use them.

Abstracts of contents
Summary of the content on the page No. 1

USER’S GUIDE
Ultra320
SCSI to PCI-X
Host Adapters
July 2003
Version 2.1
®
DB15-000192-01

Summary of the content on the page No. 2

Electromagnetic Compatibility Notices This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: 1. This device may not cause harmful interference, and 2. This device must accept any interference received, including interference that may cause undesired operation. This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable prote

Summary of the content on the page No. 3

This document contains proprietary information of LSI Logic Corporation. The information contained herein is not to be used by or disclosed to third parties without the express written permission of an officer of LSI Logic Corporation. LSI Logic products are not intended for use in life-support appliances, devices, or systems. Use of any LSI Logic product in such applications without written consent of the appropriate LSI Logic officer is prohibited. Document DB15-000192-01, Version 2.1 (July 2003

Summary of the content on the page No. 4

iv Version 2.1 Copyright © 2002-2003 by LSI Logic Corporation. All rights reserved.

Summary of the content on the page No. 5

Preface This document is the user’s guide for all LSI Logic Ultra320 SCSI to PCI-X Host Adapters. It contains a functional description of the Ultra320 SCSI host adapters as well as physical and electrical specifications. It also contains instructions for installing the host adapters and for connecting SCSI devices to them. Audience This document assumes that you have some familiarity with SCSI protocol and related support devices. This document benefits people installing and using the various Ultr

Summary of the content on the page No. 6

Related Publications LSI53C1020 PCI to Ultra320 SCSI Controller Technical Manual, LSI Logic Corporation, Document number DB14-000176-04 LSI53C1030 PCI to Dual Channel Ultra320 SCSI Multifunction Controller Technical Manual, LSI Logic Corporation, Document number DB14-000156-03 Fusion-MPT™ Device Management User’s Guide, LSI Logic Corporation, Document number DB15-000186-01 Revision Record Version Date Remarks 1.0 9/2001 This release provides information about the LSI22320-R, LSI21320, and LSI203

Summary of the content on the page No. 7

Contents Chapter 1 Quick Installation Procedures 1.1 General Description 1-1 1.2 Quick Host Adapter Installation 1-2 1.3 Quick Windows Driver Installation 1-4 Chapter 2 Detailed Host Adapter Installation 2.1 Installing your Ultra320 SCSI Host Adapter 2-1 2.1.1 Selecting a PCI Slot 2-1 2.1.2 Inserting the Host Adapter 2-3 2.2 SCSI Device Cables 2-4 2.2.1 Internal SCSI Cables 2-4 2.2.2 External SCSI Cable 2-5 2.3 Connecting SCSI Devices 2-6 2.3.1 Connecting Internal SCSI Devices 2-6 2.3.2 Connecti

Summary of the content on the page No. 8

3.1.2 LSI21320 Dual Channel Host Adapters 3-4 3.1.3 LSI22320 Dual Channel Host Adapters 3-6 3.2 Host Adapter Characteristics 3-8 3.3 Technical Specifications 3-8 3.3.1 Electrical Characteristics 3-9 3.3.2 Thermal and Atmospheric Characteristics 3-9 3.3.3 Safety Characteristics 3-10 Appendix A Glossary of Terms Customer Feedback viii Contents Version 2.1 Copyright © 2002-2003 by LSI Logic Corporation. All rights reserved.

Summary of the content on the page No. 9

Figures 2.1 Hardware Connections for the Host Adapter 2-2 2.2 Inserting the Host Adapter 2-3 2.3 SCSI Cable – 68-pin High Density with Terminator 2-4 2.4 SCSI Cable – 68-pin High Density without Terminator 2-4 2.5 SCSI Cable – 68-pin VHDCI 2-5 2.6 Connecting Internal SCSI Cable to Host Adapter 2-6 2.7 Connecting Multiple Internal SCSI Devices 2-7 2.8 SCSI LED Connector 2-8 2.9 Connecting One External SCSI Device 2-9 2.10 Connecting Multiple External SCSI Devices 2-10 3.1 LSI20320, LSI20320-R and

Summary of the content on the page No. 10

x Version 2.1 Copyright © 2002-2003 by LSI Logic Corporation. All rights reserved.

Summary of the content on the page No. 11

Tables 1.1 Ultra320 SCSI Controllers and Host Adapters 1-1 2.1 SCSI ID Record for Dual Channel Adapter 2-12 2.2 Host Adapter Installation Check List 2-13 3.1 Ultra320 SCSI, 64-bit, 133 MHz PCI-X Host Adapters 3-1 3.2 Host Adapter Characteristics 3-8 3.3 Maximum Power Requirements 3-9 xi Version 2.1 Copyright © 2002-2003 by LSI Logic Corporation. All rights reserved.

Summary of the content on the page No. 12

xii Version 2.1 Copyright © 2002-2003 by LSI Logic Corporation. All rights reserved.

Summary of the content on the page No. 13

Chapter 1 Quick Installation Procedures This chapter contains general information about Ultra320 SCSI controllers and host adapters. It provides quick host adapter installation instructions and SCSI bus setup for experienced computer users. It also provides quick installation instructions for Windows device drivers. This chapter includes these topics: • Section 1.1, “General Description,” page 1-1 • Section 1.2, “Quick Host Adapter Installation,” page 1-2 • Section 1.3, “Quick Windows Driver Ins

Summary of the content on the page No. 14

To achieve Ultra320 SCSI performance, you must connect only Low Voltage Differential (LVD) devices to the host adapter. If you connect single-ended (SE) devices and LVD devices, the entire bus will drop to the lower SE speed, limiting bus performance to Ultra SCSI. The Ultra320 SCSI host adapters support all major operating systems, such as Windows (NT 4.0, 2000, NET and XP), Linux, NetWare, UnixWare, SCO OpenServer 5.X, OS/2, and Solaris. Other software support includes SureLINK™ Domain Validat

Summary of the content on the page No. 15

Step 7. Connect the internal and external SCSI devices to connectors on one SCSI channel. Step 8. Install SCSI bus terminators at the ends of the SCSI bus. The SCSI bus must be properly terminated. Step 9. Set the SCSI IDs for all devices and record them for future reference. Step 10. Make any configuration changes. Step 11. Before replacing the cover on your computer, verify your installation: • Is the host adapter connection in the PCI-X or PCI bus slot secure? • Are the internal SCSI bus conne

Summary of the content on the page No. 16

1.3 Quick Windows Driver Installation To load the SYMMPI.SYS miniport driver during a new Windows NT, Windows 2000, Windows XP or Windows .NET system installation, you can boot directly from the Microsoft installation CD-ROM. The Windows drivers are not interchangeable; however, the instructions are very similar. To install a new Windows operating system and its appropriate device driver, follow these steps: Step 1. Have the Microsoft Windows driver diskette available to insert into drive A when

Summary of the content on the page No. 17

Chapter 2 Detailed Host Adapter Installation This chapter provides detailed instructions on how to install the LSI Logic Ultra320 SCSI to PCI-X host adapters and includes these topics: • Section 2.1, “Installing your Ultra320 SCSI Host Adapter,” page 2-1 • Section 2.2, “SCSI Device Cables,” page 2-4 • Section 2.3, “Connecting SCSI Devices,” page 2-6 • Section 2.4, “Terminating the SCSI Bus,” page 2-11 • Section 2.5, “Setting SCSI IDs,” page 2-12 • Section 2.6, “Completing the Installation,” page

Summary of the content on the page No. 18

Caution: You must touch a grounded metal surface before handling the host adapter because static charges on your body can damage electronic components. Handle plug-in boards by the edge; do not touch board components or gold connec- tor contacts. LSI Logic recommends that you use a static ground strap. Step 4. Remove your Ultra320 SCSI host adapter from its packaging and verify that it is not damaged. Figure 2.1 shows the LSI22320 host adapter. The LSI20320 and LSI21320 Ultra320 SCSI host adapte

Summary of the content on the page No. 19

2.1.2 Inserting the Host Adapter Perform the following steps to install your Ultra320 SCSI host adapter in the PC mainboard. Step 1. Remove the blank bracket panel on the back of the computer that is aligned with the PCI-X slot you have selected. Save the bracket screw. Step 2. Carefully insert the edge connector J1 of the host adapter into the PCI-X slot, as shown in Figure 2.2. Figure 2.2 Inserting the Host Adapter Bracket Screw 32-Bit Slots 64-Bit Slots Step 3. Make sure the edge connector is

Summary of the content on the page No. 20

Step 4. Be sure to tighten the bracket screw into the bracket securely before you connect the internal and external SCSI devices. 2.2 SCSI Device Cables For reliable Ultra320 operation, be sure to use an Ultra320 rated SCSI cable. The Ultra320 SCSI cable also has built-in low voltage differential and single-ended termination. This built-in feature is included because most Ultra320 SCSI hard disk drives are not made with on-board low voltage differential termination. 2.2.1 Internal SCSI Cables Yo


Alternative user manuals
# User manual Category Download
1 LSI 20860 User manual Network Card 4
2 LSI 7102XP-LC User manual Network Card 1
3 LSI 40919LH User manual Network Card 1
4 LSI 320 User manual Network Card 3
5 LSI 21003 User manual Network Card 1
6 LSI 44929LH User manual Network Card 1
7 LSI 44929H User manual Network Card 1
8 LSI 40919H User manual Network Card 0
9 LSI 7202LXP-LC, 7402XP-LC, 7202EP-LC User manual Network Card 1
10 LSI ITI7004G2- User manual Network Card 1
11 LSI 40909G-S User manual Network Card 1
12 LSI 7102XP-LC, 7102LXP-LC, 7202XP-LC, 7202LXP-LC, 7402XP-LC, 7202EP-LC, 7202EP, 7402EP-LC, 7402EP User manual Network Card 7
13 LSI 7202CP User manual Network Card 1
14 LSI 8751D User manual Network Card 2
15 LSI MegaRAID Enterprise 1600 User manual Network Card 2
16 Sony BTA-NW1A User manual Network Card 2
17 Sony BKMW-E3000 User manual Network Card 2
18 Sony AC-SQ950D User manual Network Card 0
19 Sony BBV RX100 User manual Network Card 3
20 Sony CLIE A-AVZ-100-11 User manual Network Card 1